TSAC-5999 |
Concrete components |
Concrete console (110): On the Parameters tab, you can now cut the beam part around the column. Previously, you could only cut the column. |
TSAC-7025 |
Concrete components |
Concrete console (110) (111), Concrete beam-beam (112): It is now possible to use a detail component as the socket. |
TSAC-7026 |
Concrete components |
Concrete console (110) (111): You can now select to define a corbel connection between the column and the corbel on the Picture tab. |
TSAC-7327 |
Concrete components |
Automatic splicing tool: Single bars are now correctly split and spliced regardless of their direction. Previously, single vertical bars were not handled correctly. |
TSAC-7339 |
Concrete components |
Rebar end anchor now correctly creates end detail modifiers for rebar sets in cases where only one bar is affected. |
TSAC-7372 |
Concrete components |
Floor layout: The Floor layout dialog box now correctly saves the settings defined on the User defined tab. Previously, the settings were not saved correctly if the name of the user-defined attribute was longer than 17 characters. |
TSAC-7378 |
Concrete components |
Floor layout: On the General tab, you can now specify the depth position for a specific layer. |
TSAC-7417 |
Concrete components |
Floor layout: The contextual toolbar now supports more than 5 layers. |
TSAC-7471 |
Concrete components |
Border rebar for single edge (93): The Difference in thickness setting to detect negative volume has been removed from the Configuration tab. The component now detects holes automatically.
|
TSAC-5598 |
Steel components |
Two sided clip angle (143): Previously, the flange cut created due to bolts clashing with the flange was not created for the second secondary beam in all situations. This issue has now been fixed. |
TSAC-7418 |
Steel components |
Column seating (39): Previously, bolts were not created for specific main part profile and bolt horizontal offset combinations. This issue has now been fixed. |
TSAC-7436 |
Steel components |
UltraZED Non-std side rail (91): Previously, counterforming both sets of bolts reduced the strut length at one end. This issue has now been fixed. |
TSAC-7443 |
Steel components |
Stairs (S71): Previously, special holes of bolts were not created in the correct parts. This issue has now been fixed. Special holes are now created in the correct parts as defined in the component dialog box. |
TSAC-7447 |
Steel components |
Stairs (S71): Previously, when you added another component to the top or bottom landing parts, the added component did not affect the correct part. This was caused by IDs swapped between the top and bottom landing parts. This issue has now been fixed. |
TSAC-7468 |
Steel components |
U.S. Base plate (1047): The Eliminate external bolts setting on the Parameters tab now works correctly again. |
TSAC-7484 |
Steel components |
Stiffened end plate (27): Previously, finger shim plates were created incorrectly in some cases. This issue has now been fixed. |
TSAC-7485 |
Steel components |
End plate (144): Previously, finger shim plates were created incorrectly in some cases. This issue has now been fixed. |
TSAC-7490 |
Steel components |
Stiffened end plate (27): Previously, one of the shear tab corner chamfers was not created correctly. This issue has now been fixed. |
TTSD-56336 |
Organizer |
Previously, category properties did not open if the environment or model did not have any Organizer filters. This issue has now been fixed. |
TTSD-50237 |
Import, export, interoperability |
Earlier, when you had set XS_BOLT_DUPLICATE_IGNORE to TRUE, and exported a part as DSTV, some holes were not exported because another bolted part had holes in the same location. This issue has now been fixed.
Note that you should not use this advanced option in any new models. Instead, use the No hole option for Special hole type in the Bolt properties. |
TTSD-54310, TTSD-52356 |
Import, export, interoperability |
IFC export: Earlier, the IFC export result did not contain the properties for IfcBuilding and IfcBuildingStorey. Now these properties are shown. |
TTSD-56248 |
Import, export, interoperability |
Import from Tekla Structural Designer: While importing a Tekla Structural Designer file multiple times or switching between different Tekla Structural Designer files in import, sometimes the Import button in the Tekla Structural Designer Import dialog box in Tekla Structures became unavailable. This issue has now been fixed. |
TTSD-56391 |
Import, export, interoperability |
Export to Tekla Structural Designer: Pad footings, strip footings, piles, and pile caps are now again correctly exported from Tekla Structures to Tekla Structural Designer. |
TTSD-56527 |
Import, export, interoperability |
Reference models: Sometimes the reference model list stopped responding when you scrolled the list in a certain use case. This issue has now been fixed. |
TTSD-56846 |
Import, export, interoperability |
IFC2x3 export: The boolean type property export has been improved. When you export an integer property, with options ''j_Yes'' and ''j_No'', for example, the export result shows ''true'' and ''false'', regardless of how the indexes of the options are defined in the .inp file. |
TTSD-56924 |
Import, export, interoperability |
IFC2x3 export: When you minimize the Property set definitions dialog box, it is now visible on the taskbar, and you no longer lose the dialog box. You can also locate the Property set definitions dialog box by using the Alt+Tab keyboard shortcut. |
TPLED-178 |
Templates and reports |
Previously, column headers were not positioned correctly in tables that were filled vertically from top to bottom and aligned to the right. This has now been fixed.
|
TPLED-276 |
Templates and reports |
Template Editor: Sometimes, when you moved multiple objects horizontally using the Move Object dialog box, the objects also moved vertically. This issue has now been fixed. |
TTSD-56369 |
Templates and reports |
Rebar pull-out pictures: Fixed the following issues in the placement and orientation of rebar pull-out pictures in report templates:
1. In certain cases, the pull-out picture was placed partially outside the report template field.
2. Curved rebar set bars were not optimally orientated within the report template field. |
TSAC-7059 |
Drawings |
The macros for relabeling section views and detail views are now able to handle views named with numbers correctly. |
TTSD-38607 |
Drawings |
Earlier, when using a bolt hole mark with a template attribute in single-part drawing views, the main part hole information was always shown even though the secondary part had a different hole. This issue has now been fixed. |
TTSD-48669 |
Drawings |
Drawing views: Earlier, when creating an unfolded single part drawing with a folded 3D view, the 3D view depth was incorrect. This issue has now been fixed. |
TTSD-51592 |
Drawings |
Fabrication drawings: The Creation review dialog box now supports some advanced options better for concrete parts. |
TTSD-52765 |
Drawings |
Previously, snapping to intersection points of a radial grid in drawings did not work. This has now been fixed. |
TTSD-53787 |
Drawings |
The NUMBER_IN_DRAWING attribute is now available for selection in the element list in the drawing property pane. NUMBER_IN_DRAWING can be added to associative notes, reinforcement marks, and dimension tags. |
TTSD-55912 |
Drawings |
Reference models in drawings: The DWG reference model texts in drawings are now drawn correctly also when the Outline representation is used. |
TTSD-56015 |
Drawings |
Previously, object level settings were not applied correctly in the section and detail views that were manually created using the drawing property pane. This issue has now been fixed. The property pane now applies all properties found in a loaded property file at the creation of the section and detail views. |
TTSD-56590 |
Drawings |
Pull-out pictures: Pull-out picture coupler/anchor symbols were sometimes drawn at the wrong end of the bar when short/long (_S/_L) attributes were used. This issue has now been fixed. |
TTSD-56702 |
Drawings |
Drawing property pane: The dimension property files now store an empty string for the Excluded tags filter property if you select the None option. This is to ensure that the property file works properly in different languages. |
TTSD-57169 |
Drawings |
Earlier, copying text, graphical objects, or drawing weld marks in drawings did not work if the advanced option XS_SCALE_COPIED_OR_MOVED_OBJECTS_IN_DRAWINGS was set to TRUE. This has now been fixed. |
TTSD-55756 |
Tekla Model Sharing |
Previously, Tekla Model Sharing features became inactive after write out or read in when using the Drafter license. This has now been fixed. |
TTSD-55840 |
Reinforcement |
Rebar sets: Previously, for a tapered rebar set bar group with two or more legs, at the point where the height became greater than the width (or vice versa), the leg dimensions in reports swapped around (DIM_A became DIM_B, and vice versa). This issue has now been fixed. |
TTSD-56147 |
Reinforcement |
Rebar sets: Curved bars created using rebar set leg surfaces might sometimes have an incorrect standard bending radius in rebar shape recognition, and then these curved bars did not get the correct bending shape code. This issue has now been fixed. |
TTSD-56215 |
Reinforcement |
When the bar geometry has been simplified in rebar shape recognition, the Center line length (CLL) and Sum of leg lengths (SLL) values of reinforcing bars now contain the hooks even if the advanced option XS_REBAR_RECOGNITION_HOOKS_CONSIDERATION is set to FALSE . |
TTSD-25622 |
Modeling |
In the UK environment, the calculated weights of the profiles UB533x165x66 and UB533x165x75 were incorrect due to the cross sectional area being incorrect in the profile catalog. This issue has now been fixed. |
TTSD-56952 |
Modeling |
Previously, copying bolts with different holes did not work well in the Batch editor. This has now been improved, and bolts in the target assembly should produce identical holes to the ones in the source assembly. |
TTSD-57041 |
Modeling |
Previously, copying objects by using the numeric snapping worked only once. This has now been fixed. |
TTSD-56576 |
Tools and components |
Previously, Tekla Structures occasionally shut down after a custom component was edited. This has now been fixed. |
TTSD-56622 |
User interface |
The property pane now reacts normally to selection changes after a tool such as Rebar shape manager or IFC export was used. Previously, the property pane did not get updated until a regular ribbon command was used, for example. |
TSAC-7278 |
Import, export, interoperability (steel) |
DTSV to DXF converter: Hardstamp and inner corner roundings are now converted correctly for the back side. |
TTSD-45103 |
Import, export, interoperability (steel) |
DSTV/NC export: In some cases, the inner contour (IK block) has been omitted from the NC export for plates that contain weld preparations. This issue has now been fixed. |
TTSD-50478 |
Import, export, interoperability (steel) |
NC/DSTV: Sometimes, the NC export created erroneous weld preparation data into NC file AK or IK blocks for I beams. This issue has now been fixed. |
TTSD-56333 |
Import, export, interoperability (steel) |
DSTV/NC export: Previously, the blind hole depth was not exported to the NC file when the bolt had a negative cut length. This issue has now been fixed. |
TSAC-7453 |
Import, export, interoperability (concrete) |
Export ELiPLAN file (68): Previously, the data conversion file mapping did not work for profiles that had parentheses in the profile name. This issue has now been fixed. |