Tekla Structures 2023 - lista poprawek
Tekla Structures 2023 zawiera wszystkie poprawki wydane w dodatkach service pack Tekla Structures 2022 do wersji SP7. Te poprawki nie znajdują się na liście poprawek dla wersji Tekla Structures 2023.
Tekla Structures 2023 zawiera wszystkie poprawki wydane w dodatkach service pack Tekla Structures 2022 do wersji SP7. Te poprawki nie znajdują się na liście poprawek dla wersji Tekla Structures 2023.
Numer defektu | Obszar rozwoju | Opis |
---|---|---|
TSAC-3772 | Concrete components |
|
TSAC-6856 | Concrete components | Floor layout: The Line up direction setting on the General tab now works correctly. Previously, if you had the insulation layer as the lower layer and changed the line up direction, the insulation was not created correctly. |
TSAC-6904 | Concrete components | Starter bars for footing (87) now takes the local plane of the pad footing into account. Previously, the global orientation was taken into account, and this caused rotated pad footings with starter bars to have different numbering. |
TSAC-6950 | Concrete components | Mesh bars, Mesh bars by area: When the cover thickness values for the openings or recesses by cuts are not defined, the cover thicknesses for rebar ends defined on the Bar end condition tab are used instead. |
TSAC-7019 | Concrete components | Floor layout: The CIP filler part is no longer created outside the component polygon boundaries. |
TSAC-2695 | Steel components | Metsec File transfer (26): Metsec apex strut CAM data is improved to allow for situations when purlins are set between or below the rafters. |
TSAC-4476 | Steel components |
Stiffeners (1034): Previously, the welds between the stiffeners and the part were created in an incorrect position. This issue has now been fixed. |
TSAC-6532 | Steel components | Metsec Horizontal cladding support column (33): Metsec CAM data for the horizontal cladding connection at the column has been updated to correct the cleat positions shown in the CAM. |
TSAC-6696 | Steel components | CMF Mezzanine floor connection (149): Weld settings are no longer available in the component dialog box. |
TSAC-6726 | Steel components | Kingspan Standard tie bay (10): Previously, when using the component, the hole in the top CSC was not applied. This issue has now been fixed. |
TSAC-6739 | Steel components | Welded to top flange (147), Full depth (184): The assembly numbering prefix and start number now correctly use the default value defined in Settings > Options > Components. |
TSAC-7042 | Steel components | Joining plates (14): Previously, galvanizing holes were not created correctly in the second end plate. Now sinkholes are created into all end plates. |
TSAC-7109 | Steel components | Gusset+ T: The stiffener chamfer is now created to the web of the main part. |
EPM-6996 | Import, export, interoperability | Export to Tekla PowerFab: When assembly marks in Tekla Structures were split by phase, the drawings could get mismatched. This issue has now been fixed. |
TTSD-53619 | Import, export, interoperability | Reference models: The occasional problem causing freezing and black screen when using face picker with complex reference model objects, especially when rotating the model, has now been fixed. |
TTSD-53542 | Templates and reports | Previously, template attributes for reinforcements for any value starting with "PHASE." returned the object's phase name. Now the template attributes return the correct value. For example, "PHASE.NAME" returns the phase's name and "PHASE.COMMENT" returns the phase's comment. |
TTSD-44775 | Drawings | Multi-drawing links were not correctly preserved when drawing was split during numbering. This issue has now been fixed. |
TTSD-48119 | Drawings | Multi-drawings that have copied views now correctly highlight the objects in the model when you click the Select objects in the model for selected parts button in Document manager. |
TTSD-48440 | Drawings | Bolts in general arrangement drawings: |
TTSD-49056 | Drawings | Moving views between drawings did not always work correctly. The functionality has now been improved. |
TTSD-54894 | Drawings | Rebar pull-out pictures: In some cases, planar rebar pull-out pictures were not correctly oriented towards the view. This issue has now been fixed. |
TSAC-7022 | Reinforcement | In Rebar shape manager, the preview of the selected bar shape did not work properly with 3D bars. The visualization of 3D bars has now been fixed. |
TTSD-32757 | Reinforcement | Rebar sets: When a rebar set with leg surfaces is copied or moved to a part whose geometry differs from the original part, the leg surfaces now automatically adapt to the geometry of the destination part. |
TTSD-37806 | Reinforcement | Rebar sets: With the Standard lapping option in the Rebar splitter properties, the lap length of the smaller bar is now used. Previously, the lap length of the larger bar was used. |
TTSD-47466 | Reinforcement | An issue was fixed where the |
TTSD-49255 | Reinforcement | Rebar sets: Some issues were fixed that caused bar geometry to be incorrectly calculated, so short bar legs were protruding out of rather than into the concrete part. |
TTSD-52980 | Reinforcement | Rebar coupler related UDAs ending in Note that if this issue has been worked around in templates with an "if" statement, that workaround should be removed in Tekla Structures 2023. |
TTSD-45752 | Modeling | The applied values in the property pane are not reset to standard after multi-user save but they are preserved, in the same way as in the old dialog boxes. |
TTSD-48002 | Modeling | Previously, modifying non-special UDAs in the property pane could cause the object numbering being marked as not up-to-date in certain cases. This has now been fixed. |
TTSD-53609 | Modeling | Cast in place parts are now correctly visualized on all zoom levels. |
TTSD-55548 | Modeling | Bolts: Earlier, in Tekla Structures 2022, if you modeled a bolt that went through two or more parts and that had a negative cut length, the bolt was placed incorrectly. This issue has now been fixed. |
TTSD-55968 | Modeling | Rebar assemblies: The Locked user-defined attribute has now been added for rebar assemblies. |
TTSD-56274 | Modeling | Bolts: Earlier, in Tekla Structures 2022, bolts were incorrectly positioned when beams or columns were deformed by shortening. The incorrect positioning occurred when |
TTSD-53372 | Licensing | Now the dashed hidden lines are shown correctly behind objects, instead of being shown in front in transparent view modes. |
TTSD-50645 | User interface | Now, when you hover the mouse pointer over side pane window, pressing Ctrl+F1 opens the corresponding help page in Tekla User Assistance. |
EPM-6627 | Import, export, interoperability (steel) | Export to Tekla PowerFab: DSTV files are now exported in UTF-8 without the byte-order-mark (BOM). |
TSAC-6846 | Import, export, interoperability (concrete) | Export Unitechnik (79): Previously, double values exported from a UDA were exported with an incorrect number of decimals. This issue has now been fixed. |
TSAC-6656 | Common | In some cases 2D Library caused Tekla Structures to freeze when running numbering in multi-user mode. This issue has now been fixed. |