TSAC-8153 |
Concrete components |
Wall to wall connection: Shortening the wall now works correctly again. |
TSAC-8210 |
Concrete components |
Embedded anchors (008): Previously, reading anchors from a configuration file was available only for custom part type of anchors. Now this is available also for custom detail and connection type of anchors. |
TSAC-8420 |
Concrete components |
Reinforced concrete stair (95): Creating only the bottom group of rebars now works correctly for top and bottom landing stirrups. |
TSAC-7856 |
Steel components |
Shear plate simple (146): The Clearance of cut from web setting on the Notch tab now works correctly when the XS_ALLOW_SHEAR_PLATE_CLASH_FLANGE advanced option is set to TRUE. |
TSAC-8157 |
Steel components |
Shear plate to tube column (47): Previously, the slot through the main part was not created correctly when the shear tab was sloped. This issue has now been fixed. |
TSAC-8192 |
Steel components |
Tube gusset (20): Previously, when the secondary parts were located on both sides of the main part, the weld between the gusset and the main part was created incorrectly. This issue has now been fixed. |
TSAC-8225 |
Steel components |
Beam to column web connections: Previously, the advanced option XS_STANDARD_STIFFENER_WIDTH_TOLERANCE was used also for partial width stiffeners. This issue has now been fixed. |
TSAC-8467 |
Steel components |
Tube gusset (20): Previously, an incorrect distance between the main part and the connection plate was used in some situations. This issue has now been fixed. |
TSAC-8480 |
Steel components |
Tube gusset (20): It is now possible to define the gusset plate location when the secondary parts are located on both sides of the main part. |
TSAC-8486 |
Steel components |
Simple base plate 2 (1031): Previously, the weld between the key profile and the base plate was not created correctly. This issue has now been fixed. |
TSAC-8489 |
Steel components |
Shear plate simple (146): Previously, the cut for bolt clearance was created also when it was not needed. This caused problems with numbering. Now this issue has been fixed. |
TSAC-8493 |
Steel components |
Joist seat (58): Previously, the prefix and start number for the part position number of the bottom shear tab was not correctly applied. This issue has now been fixed. |
TSAC-8512 |
Steel components |
Cold rolled overlap (1): Previously, stays were created incorrectly if the sum of the main and secondary part heights was higher than 1800 mm. This issue has now been fixed. |
TSAC-8528 |
Steel components |
Railings (S77): Previously, setting the maximum length of the bottom rail to 0.0 caused Tekla Structures to stop working. This issue has now been fixed. |
TTSD-45368 |
Import, export, interoperability |
Export to Tekla Structural Designer: In the analysis model export from Tekla Structures to Tekla Structural Designer, concrete parts are now exported using the same rules as steel parts.
- The analysis axis of each part in Tekla Structures is used as the insertion line in Tekla Structural Designer.
- The Tekla Structures part position is mapped to the Tekla Structural Designer alignment.
- The major and minor offsets are adjusted in Tekla Structural Designer to get the member in the correct place.
|
TTSD-63344 |
Import, export, interoperability |
Export drawings as DWG/DXF/DGN: Drawing export rule settings are now displayed and loaded faster. |
TTSD-63401 |
Import, export, interoperability |
IFC export: You can now export string type UDAs longer than 80 characters to IFC files. |
TTSD-64002 |
Import, export, interoperability |
Tekla Structures stopped responding when reading an invalid IFC export property set file. This issue has now been fixed. |
TTSD-63060 |
Templates and reports |
Drawing layout tables: The line width was not always correct in drawing tables. This issue has now been fixed. |
TTSD-63682 |
Templates and reports |
Custom inquiry: Earlier, when using a formula with a property whose value was very close to zero and so small that scientific format was needed (for example, 5.4*10-8), the value of the formula was not shown correctly in Custom inquiry. This issue has now been fixed.
|
TSAC-8479 |
Drawings |
Rebar pull-out picture and marking: Now all of the mark content is updated automatically. Earlier, if the mark contained a UDA, for example REBAR_SEQ_NO, and you changed the value of the UDA in the model without making any other modifications to the rebar, the UDA value in the mark was not updated and was still showing the old value, and you had to update the mark manually.
NOTE: The fix was technically implemented so that the mark creation now uses associative note instead of plain text. As a side effect of this, the vertical alignment of the elements in the mark content has changed from center aligned to bottom aligned.
|
TTSD-21818 |
Drawings |
Earlier, when you created an unfolded single part drawing of a polybeam that had cuts, the bending lines were not placed correctly in the center of the cuts. When the polybeam profile did not have a prefix, the bending line was not shown at all. These issues have now been fixed. |
TTSD-60565 |
Drawings |
Earlier, when you created an unfolded single part drawing of a polybeam that had cuts, the bending lines were not placed correctly in the center of the cuts. This issue has now been fixed.
|
TTSD-64028 |
Drawings |
When selecting a new symbol in the drawing property pane, the symbol index number was not automatically updated to reflect the new selection in the Mark content - symbol dialog box. This issue has now been fixed. |
TTSD-64048 |
Drawings |
Sometimes drawing view properties did not fully load, resulting in the loss of settings such as mark leader line arrowheads. This issue has now been resolved, and drawing view properties now load correctly. |
TTSD-64064 |
Drawings |
Drawing cloning: The section views are now handled better in drawing cloning. For example, the logic for updating and cloning the views was improved. |
TTSD-64333 |
Drawings |
Drawing text objects in property pane: The down arrow is now supported in the property pane when editing the text of the text object. |
TTSD-64346 |
Drawings |
Earlier, when using the PROFILE attribute in drawing view titles, the shape GUID was shown instead of the shape name for items. This issue has now been fixed. |
TTSD-64473 |
Drawings |
Part reference lines: The Color property box for reference lines now shows the correct color in the Part Properties dialog box. Earlier, the Color property box was blank. |
TTSD-62968 |
System and options |
standard.*.more files are now again available in the Common and Default environments. This fixes an issue where standard file loading did not clear the values of the user-defined attribute dialog box when the dialog box was already open. |
TTSD-63193 |
Tekla Model Sharing |
Tekla Model Sharing: Previously, when you wrote out, the error message for a locked file did not contain the correct reason. This has now been fixed. |
TTSD-64338 |
Reinforcement |
Rebar sets: An issue has been fixed that would cause layering problems with slightly inaccurate rebar set leg faces. |
TTSD-58840 |
Modeling |
BCF Topics: Previously, some top views created in Trimble Connect were rotated 90 degrees when they were loaded in Tekla Structures. This has now been fixed. |
TTSD-63863 |
Modeling |
Now, when you copy properties in the property pane, the property pane does not reset the possible manual modifications that you have done. |
TTSD-64062 |
Modeling |
Previously, clip plane edges were not visualized in cases where there were front facing faces behind the edge of a back facing clipped face. This has now been fixed. |
TTSD-64118 |
Modeling |
Previously, if the base curves of lofted plates had a small difference on the border of accuracy that Tekla Structures uses, opening models with such plates caused Tekla Structures to be unexpectedly closed. This has now been fixed. |
TTSD-64143 |
Modeling |
BCF Topics: Now, you can link objects to a topic and view the linked objects both in Trimble Connect and Tekla Structures when you are working with both the .tekla and .ifc files. |
TTSD-64269 |
Modeling |
Previously, if you used the Clip references only option to create clip planes, the clip plane was also clipping the part edge lines when their representation was only the Level Of Detail (LOD) stick in the zoomed out view. This has now been fixed. |
TTSD-64369 |
Modeling |
Previously, when copying objects using numerical input and not using the dialog box, the copying was done with respect to copy origin. This has now been fixed, and the copying is done with respect to the last copy, as in previous Tekla Structures versions. When you pick points, the dimensions are now also shown with respect to the last copy or the last picked point.
This fix reverts TTSD-56113, which was released in Tekla Structures 2024 SP2. |
TTSD-64004 |
Analysis and design |
Import from Tekla Structural Designer: While importing analysis results from Tekla Structural Designer to Tekla Structures, some incorrect warnings were shown in the process log. This issue has been addressed and corrected now. |
TTSD-63941 |
Tools and components |
Macros: Some recorded keystroke macros did not work. This issue has now been fixed. |
TTSD-64394 |
User interface |
Property pane: The Expand all button in the Property pane settings now works. |
TSAC-8415 |
Import, export, interoperability (concrete) |
BVBS export: Rebar groups modeled as normal groups are no longer processed as tapered. |
TSAC-8527 |
Import, export, interoperability (concrete) |
Export Unitechnik (79): Searching for the embed name in the Special export assembly file name field is no longer case sensitive. Previously, if you used a different case in the search than what the file had, the file was not found. |
TSAC-8539 |
Import, export, interoperability (concrete) |
Export ELiPLAN file (68): Previously, skewed cuts at the start or at the end of the hollowcore profiles caused incorrect length of the exported hollowcore profile. This issue has now been fixed. |
TSAC-8542 |
Import, export, interoperability (concrete) |
Export ELiPLAN file (68): Previously, edge cuts at the start or at the end of the hollowcore profiles caused incorrect length of the exported hollowcore profiles. This issue has now been fixed. |