Numéro de défaut | Zone de développement | Description |
---|---|---|
TSAC-8524 | Concrete components | Wall to wall connection: The rebar depth of rebar loop connectors has now been fixed for the left end L shape. |
TSAC-8649 | Concrete components | Seating with dowel (75): Previously, when the secondary beam part was sloped, the created parts were aligned incorrectly and did not have the correct offset. This issue has now been fixed. |
TSAC-8798 | Concrete components | Lifting anchor (80): Previously, anchors disappeared with a certain combination of anchor position and empty value for the offset distance between the anchor and the centerline of the part. |
TSAC-8810 | Concrete components | Concrete console (111): Hole generation around anchors for special shapes of beams now works correctly. |
TSAC-8841 | Concrete components | Concrete console (110): Previously, the lateral cut around the column disappeared when the beam was fitted to the column web. This issue has now been fixed. |
TSAC-8847 | Concrete components | Reinforcement mesh array (91): The left and right overhang of the mesh are now read and set from the rebar catalog properly. |
TSAC-8882 | Concrete components | Embedded anchors (008): Placing of anchors has been improved so that the anchors are always attached to a concrete material. |
TSAC-8931 | Concrete components | Automatic splicing tool now works correctly with imperial units. |
TSAC-7939 | Steel components | U.S. Base plate (1047): Previously, bolt holes were created incorrectly in extra plates when some of the anchors were deleted. This issue has now been fixed. |
TSAC-8905 | Steel components | Tube gusset (20): Previously, gusset plate chamfers were not created in some situations. This issue has now been fixed. |
TSAC-8926 | Steel components | Two sided end plate (142): Previously, bolts with zero quantity were created in some situations. This issue has now been fixed. |
TSAC-8935 | Steel components | HiSpan File transfer (100): CAM data has been updated to allow holes detailed on the center line of the sections. |
TSAC-8939 | Steel components | Two sided end plate (142): Previously, in some situations, bolts were not created when filler plates were used. This issue has now been fixed. |
TSAC-8952 | Steel components | Multiple stiffeners (1064): Previously, arc chamfers on stiffeners were not created unless both chamfer sizes were defined. This issue has now been fixed. Arc chamfers are created when at least one of the sizes is defined. |
TSAC-8964 | Steel components | HSS Brace special (67): Previously, the cap plate width and height were not correctly applied. This issue has now been fixed. |
TSAC-8971 | Steel components | Full depth S (185): Previously, when the secondary part was cut with a square end cut, the bolt edge distance was not correctly applied. This issue has now been fixed. |
TSAC-8976 | Steel components | End plate (29): Previously, welds were created incorrectly when the secondary part was rotated. This issue has now been fixed. |
TSAC-8999 | Steel components | Tube gusset (20): On the Gusset tab, it is now possible to create four chamfers on the gusset plate when the gusset is created on a column. |
TSAC-9001 | Steel components | Windbracing (S55): The default numbering prefixes and start numbers now depend on the settings defined in File menu > Settings > Options > Components. |
TSAC-9058 | Steel components | Stub connection (119): Previously, weld 8 between the haunch plates and end plates was created incorrectly. This issue has now been fixed. |
TSAC-9077 | Steel components | Tube gusset (20), Tube crossing (22): Previously, the middle end plate was created with an incorrect height. This issue has now been fixed. |
TSAC-9083 | Steel components | Joining plates (14): Previously, galvanizing holes were not created when the thickness of end plates was more than 50 mm. This issue has now been fixed. |
TTSD-64886 | Organizer | Previously, when importing categories from an IFC file to Organizer, there was an error when multiple hierarchical relations between different elements in the IFC model shared the same unique identifier. Now this issue has been fixed. |
TTSD-65463 | Import, export, interoperability | IFC4 export: Previously, the user-defined attribute values that were inherited from the assembly main part were not written to assembly objects in the IFC4 export. This issue has now been fixed as follows: Notes:
|
TTSD-65528 | Import, export, interoperability | Previously, the upload to Trimble Connect did not succeed sometimes. This has now been fixed. |
TTSD-66231 | Import, export, interoperability | Point clouds: Some .e57 point clouds could not be attached. This issue has now been fixed. |
TTSD-67244 | Import, export, interoperability | IFC export: Previously, exporting model entities with calculated values could take a very long time. This issue has now been fixed. |
TTSD-67452 | Import, export, interoperability | Reference models: Earlier, Tekla Structures stopped responding when unsupported characters were used in the path copied to the File box in the Reference models side pane. Copying added quotes around the path automatically. The surrounding quotes are now removed to support the Copy as path feature in Windows Explorer. |
TTSD-68423 | Import, export, interoperability | Assembly UDAs in IFC4 export: Previously, IFC4 export always used the UDA value from the main part of the assembly if the assembly did not have it defined. Now, you can disable this functionality using the advanced option XSR_DISABLE_ASSEMBLY_UDA_INHERITANCE. If you set the advanced option to TRUE, and if UDA is not set on the assembly level, the UDA is left empty or it uses assembly level's default value. If you set it to FALSE, the UDA is inherited from the main part. |
TPLED-330 | Templates and reports | Template attributes: Sometimes the PAGES attribute returned an incorrect value. This issue has now been fixed. |
TPLED-353 | Templates and reports | In a drawing template, if there were rows that were not divided into columns and these rows were output after rows that were divided into columns, the required height of the template could not be calculated correctly. This resulted in overlapping rows and overlapping templates. This issue has now been fixed. |
TTSD-49618 | Templates and reports | Scale in templates is now reported more consistently. |
TTSD-68592 | Templates and reports | PDF reports: Creating PDF reports works now more reliably. Previously, the last page could be left out. |
TSAC-8641 | Drawings | You can now run the Rebar mesh view creator tool from the command line. |
TTSD-67102 | Drawings | Printing: Printing to multiple printers was not working correctly. This issue has now been fixed. |
TTSD-67318 | Drawings | Tekla Structures sometimes stopped responding while the Drawing versions dialog was open. This issue has now been fixed. |
TTSD-67339 | Drawings | Drawing marks: The mark text color palette control now works correctly when you press the Enter key on the keyboard. |
TTSD-67575 | Drawings | Adding links to images in drawings: The All files option is now available in the Image property pane when you are adding a link to an image in a drawing. |
TTSD-67786 | Drawings | Drawing marks: Sometimes a whole mark would become hidden when you clicked Modify in the drawing property pane if you had set the frame color invisible. This issue has now been fixed. |
TTSD-67970 | Drawings | A drawing section view is now able to associate to a cut object that belongs to a component. |
TTSD-67993 | Drawings | Previously, the values of the user-defined attributes were not shown in the mark visual editor but only in the drawing. Now the user-defined attribute values are shown both in the mark visual editor and in the drawing. |
TTSD-68000 | Drawings | Rebar marks: The NUMBER_OF_BARS_IN_GROUP attribute returned only the number of visible bars in the drawing view rather than the total number of bars in the group. This issue has now been fixed. |
TTSD-68452 | Drawings | Drawing property pane: Showing different property groups in the drawing property pane works now more reliably when you have migrated settings from a previous Tekla Structures version to the current version. Previously, some property groups were not shown. |
TTSD-68512 | Drawings | Cloning drawings: Now, drawing section views are not removed in drawing cloning unless they are empty. |
TTSD-68831 | Drawings | When you accidentally used a border line when trimming a polygon, Tekla Structures stopped responding. This issue has now been fixed. |
TTSD-68994 | Drawings | Integrated dimensions: Earlier redimensioning an unfolded view did not work correctly, for instance, the bending line dimensions were missing. This issue has now been fixed. |
TTSD-68776 | Reinforcement | Previously, Rebar shape manager did not check reversed bar geometry if no shape code was found. This could result in it showing Unknown. This issue has now been fixed. Note that this issue only existed in Rebar shape manager, reporting was working correctly. |
TTSD-61866 | Modeling | Clash check manager: Previously, clashes were not detected between CHS profiles in some cases. This issue has now been fixed. |
TTSD-64201 | Modeling | Previously, edges for CIP parts were not visible when the advanced options XS_DO_NOT_CLIP_NATIVE_OBJECTS_WITH_CLIP_PLANE and XS_ENABLE_POUR_MANAGEMENT were set to TRUE. Now, the CIP part edges are visible, as they should. |
TTSD-68349 | Modeling | Previously, when you copied the properties of model objects, the part profile properties were sometimes copied even though that was not wanted. This has now been fixed. |
TTSD-68814 | Modeling | Previously, the center line of polybeams with segments at 180 degrees was calculated incorrectly. This has now been fixed. |
SOLD-2579 | Licensing | In some cases where the computer went to sleep while a model was open in Tekla Structures and the computer was offline when the user started it again, the Tekla Structures toolbar was dimmed and work could not continue even after reconnecting to the network. This has now been fixed. |
TTSD-66554 | Core | The stability of Tekla Structures when working with lofted plates has been improved. |