TSAC-1948 |
Concrete components |
Floor layout: Geometry calculation has been improved in situations when openings are collinear but not overlapping to any edge at the seam. |
TSAC-4103 |
Concrete components |
Wall layout connector has been improved. Now the connector's L corners work for wall layouts with different top and bottom heights. The corner item's top and bottom are matching only where the walls connect. |
TSAC-5099 |
Concrete components |
Floor layout: Previously, holes and cuts that should have been created automatically were not created if the cutting part was located in the negative offset area, that is, outside the input polygon. This has now been fixed.
|
TSAC-5120 |
Concrete components |
Hole generation (32): Rebar sets in a part will now be automatically cut. |
TSAC-5737 |
Concrete components |
Concrete beam-beam (112): You can now use the Create washers symmetrically setting on the Anchors tab to define whether the washers on the anchors are created symmetrically (mirrored) to the washers on the anchors at the opposite beam side. |
TSAC-5753 |
Concrete components |
Embedded Anchors (8): The Avoid reinforcement setting on the Placement tab now detects all rebars in collision with each created anchor and moves the anchors out of the collision with a cover thickness. Also, the detection works in the range of the anchor bounding box + the desired cover thickness.
|
TSAC-5808 |
Concrete components |
Floor layout: Previously, when creating automatic cut-outs for I-shaped columns, only a small cut was created at one flange if the I shape web was not touching the slab. This has now been fixed. |
TSAC-6072 |
Concrete components |
Wall layout connector: Previously, the corner part was sometimes not created because the part profile was not correct. This has now been fixed. |
TSAC-6073 |
Concrete components |
Floor layout: The Floor layout dialog box now opens correctly when you specify that there are no UDAs listed on the User defined tab. Previously, you had to have at least one UDA on the User defined tab. |
TSAC-5466 |
Steel components |
Base plate (1042): Previously, the distances from the flange of the main part to the edge of the base plate were swapped in the component. This has now been fixed. |
TSAC-5572 |
Steel components |
Round tube (23): Previously, the fitting of the secondary part was created incorrectly in some orientations of the secondary part. This has now been fixed. |
TSAC-5602 |
Steel components |
Splice plate 2 (62): Previously, the primary web bolts assembly was not applied correctly. This has now been fixed. |
TSAC-6057 |
Steel components |
Stiffened end plate (27), Partial stiffened end plate (65): Previously, bolt edge distances were incorrectly applied in the component. This has now been fixed. |
TSAC-6069 |
Steel components |
Clip angle (141): Previously, extra length was not correctly applied for all bolts. This has now been fixed. |
TSAC-6097 |
Steel components |
Full depth (184): Previously, some notch cuts were created with infinite length. This has now been fixed. |
TTSD-48084 |
Steel components |
Previously, in some rare cases, when you modified the properties of a component and had selected the ignore other types option, certain properties of some other components were still modified. This has now been fixed.
|
EPM-4558 |
Import, export, interoperability |
Export to Tekla EPM: CNC files that are copied during the export are now preserved in the same directory structure they were copied from.
|
EPM-5052 |
Import, export, interoperability |
Export to Tekla EPM: Exporting to Tekla EPM from an assembly selection in the Tekla Structures model is now supported. |
EPM-5537 |
Import, export, interoperability |
Export to Tekla EPM: The Standard settings are now reloaded when the window is closed and reopened. |
EPM-5692 |
Import, export, interoperability |
Export to Tekla EPM: A field has been added to the XML file exported from Tekla Structures, telling what version of the plugin was used to create the file. |
EPM-5717 |
Import, export, interoperability |
Export to Tekla EPM: If no settings file is found when you run the plug-in, one is automatically created with default options. |
EPM-5718 |
Import, export, interoperability |
Export to Tekla EPM: The Save button did not save the current settings correctly. This has now been fixed. |
EPM-5744 |
Import, export, interoperability |
Export to Tekla EPM: PROJECT.NUMBER can now be included in advanced settings to print drawings, and will be found when those drawings are copied into the zip file exported to Tekla EPM. |
TTSD-44018 |
Import, export, interoperability |
IFC2x3 export: Previously, additional property sets did not work on reinforcing meshes. This issue has now been fixed. |
TTSD-45311 |
Import, export, interoperability |
Point clouds: The .tdx point cloud file format is now supported. |
TTSD-46056 |
Import, export, interoperability |
IFC4 export: It is now faster to export IFC files containing property sets reporting hierarchical information. For example, mapping a property set to report "POUR_UNIT.NAME" (the name of the pour unit that a rebar belongs to) would slow down the export tremendously. This has now been fixed. |
TTSD-46672 |
Import, export, interoperability |
Trimble Connect: An error message is now displayed if the model upload to Trimble Connect fails. |
TTSD-47152 |
Import, export, interoperability |
IFC2x3 export: Weld coloring has been improved when you use current view colors. |
TTSD-47266 |
Import, export, interoperability |
IFC export: The IFC export is using translation strings from all folders mentioned for the XS_MESSAGES_PATH advanced option. |
TTSD-47437 |
Import, export, interoperability |
Reference models: Inserting an IFC model as a reference model was slow in a certain use case. This issue has now been fixed. |
TTSD-47531 |
Import, export, interoperability |
IFC2x3 export: Bolt and weld colors are now correct when you export with or without current view colors, or using user-defined colors, or colors defined by class. |
TTSD-48082 |
Import, export, interoperability |
Previously, you could not export IFC4 property sets for location breakdown structure properties (for example, LOCATION_BREAKDOWN_STRUCTURE.LBS_FLOOR). This issue has now been fixed. |
TPLED-213 |
Templates and reports |
The Valuefield did not give a correct result when the formula had a CopyField() function and used directly or by a reference the ROW_IN_PAGE attribute. This issue has now been fixed. |
TPLED-217 |
Templates and reports |
Template Editor: Circles in an imported DWG image sometimes had an incorrect color, and filled polylines could be missing. This has now been fixed. |
TSAC-5394 |
Drawings |
Rebar pull-out picture and marking: The hook representation has been improved, and 135 and 180 degree hooks are now correctly visualized. |
TSAC-5634 |
Drawings |
Rebar pull-out picture and marking: You can now define the pull-out picture scale on the Rebar tab. In Type, select Auto or Custom. If you selected Custom, type the needed Scale value. |
TSAC-5905 |
Drawings |
Automatic dimensioning with the Shape dimensions dimensioning type could hang Tekla Structures in some cases when round geometry was dimensioned. This has now been fixed. |
TSAC-5916 |
Drawings |
Rebar pull-out picture and marking: The rotation of the rebar sets has been improved. Previously, the rotation of the pull-out was not always matching the bar in the drawing. |
TSAC-6013 |
Drawings |
Drawing dimensioning performance has been significantly improved when you use the Filter dimensions method to dimension reinforcement. |
TTSD-26401 |
Drawings |
Hidden rebar lines that were not visible in the drawing mode were sometimes visible in printed output and snapshots. This has now been fixed. |
TTSD-41841 |
Drawings |
PDF reports with images on each page quickly became very large the more pages there were. This issue has now been fixed. |
TTSD-44484 |
Drawings |
Document manager: Drawings with container views now work correctly with the Select objects in the model for selected drawings command.
|
TTSD-45025 |
Drawings |
Layout editor: Layout editor now allows you to edit the size width and height by selecting the appropriate cell and pressing the Enter key. |
TTSD-45477 |
Drawings |
When using the on/off button in the old drawing view properties dialog boxes, not all the check boxes in the dialog box changed their state. This issue has now been fixed.
|
TTSD-46058 |
Drawings |
Pressing the Tab key on the keyboard for changing the current snapping location works again in drawings. |
TTSD-46577 |
Drawings |
Recess symbols now work correctly in drawings also when the part representation is Base box. |
TTSD-47191 |
Drawings |
Printing: Previously, printing would fail if there were any errors in the TeklaStrutures.lin line type file, now any unrecognized lines will be ignored. Unrecognized line styles will be logged and drawn with a solid line, matching the drawing editor. |
TTSD-47421 |
Drawings |
Reading dimensioning rule files from relative folders using advanced options XS_FIRM and XS_PROJECT is now possible. For example, XS_FIRM=".\ts" can be used to read files from the 'ts' folder inside the model folder. |
TTSD-47570 |
Drawings |
Printing: Symbols located in paths containing non-Latin characters did not always appear in printouts. This issue has now been fixed. |
TTSD-47752 |
Drawings |
Earlier, all reference models were handled when creating single-part drawings, which caused a performance issue. This has now been fixed. |
TTSD-47839 |
Drawings |
In the old Single-part drawing properties dialog box pressing the on/off button did not change the state of the Weld mark check box. This issue has now been fixed. |
TTSD-47853 |
Drawings |
Layout editor: The template width was not calculated correctly for a template with a variable number of columns, which caused the anchoring point to not adjust correctly. This has now been fixed. |
TTSD-47863 |
Drawings |
A staircase component has in one occasion caused invalid geometry to a part, causing the drawing containing the part to freeze during the drawing opening. This has now been prevented. |
TTSD-48164 |
Drawings |
Document Manager: Document Manager was not updated to reflect the file changes in the watched subfolders. This issue has now been fixed. |
TTSD-48613 |
Drawings |
Dimension associativity: Dimension associativity rules for weld preparation cuts now show a correct label instead of an empty text. |
TTSD-48711 |
Drawings |
Printing: Scaled hatch pattern lines with a delta Y of less than 0.01 mm caused hatching to fail to prevent excessive processing and hanging, which caused asserts when printing. This has now been fixed. |
TTSD-46286, TTSD-48108 |
Modeling |
Previously, splitting a lofted plate or a lofted slab using the Split command did not work. This has now been fixed. |
TTSD-46883 |
Modeling |
Previously, Tekla Structures handles were difficult to select. This has now been fixed, and the handle selection is easier. |
TTSD-47169 |
Modeling |
The log file for usage data, UserFeedbackLog.txt, is now stored in the Logs folder under the path defined with XSUSERDATADIR in teklastructures.ini file. |
TTSD-47462 |
Modeling |
Previously, modifying concrete panels could sometimes cause Tekla Structures to close suddenly. This has now been fixed. |
TTSD-47792, TTSD-48445 |
Modeling |
Previously, in the US Imperial environment, the maximum possible supported precision for bolt size was 1/16. This resulted in incorrect bolts being added to the model from the bolt catalog. Now the precision has been increased to 1/128. |
TTSD-47798 |
Modeling |
Previously, when using the Split command, the splitting of a part was not accurate if the picked point for splitting was outside the part. Now, dimensions and a preview is shown when a part is split, even from outside the part itself. For polybeams only dimensions are shown, not the preview. |
TTSD-47983 |
Modeling |
Previously, it was not possible to save or load surface treatment pattern properties or user-defined attributes in the property pane. This issue has now been fixed. |
TTSD-48371 |
Modeling |
Clash check manager now detects clashes between reference model objects and objects inside components.
|
TTSD-48510 |
Modeling |
Sometimes when loading bolt properties from a file in the US metric environment, the bolt size was not set correctly in the property pane. This issue has now been fixed. |
TTSD-48520 |
Modeling |
Previously, deleting many selected objects was extremely slow. The performance problem causing this has now been fixed. |
TTSD-48546 |
Modeling |
Lofted plate geometry for antimaterial and addmaterial was removed during a database repair, if XS_DELETE_UNNECESSARY_INT_ARRAYS was set to TRUE. This led to corrupted antimaterial/addmaterial and to a failed solid of the part influenced by the antimaterial/addmaterial. This issue has now been fixed. Additionally, these errors are now reported when models with already removed geometry are being diagnosed.
|
TTSD-48751 |
Modeling |
Previously, when using the Open properties command for grid lines on the contextual toolbar, both the old Grid line properties dialog box as well as the property pane was shown. This has now been fixed. |
TTSD-47254 |
Installation |
Previously, when trying to install an environment, there could be an error in .tsep file installation if the user's computer was configured to use a virtual desktop. The folder path to the virtual desktop could not be accessed and the .tsep package validation did not succeed. This issue has now been fixed and the installation now continues. Note that .tsep shortcuts cannot be created on the virtual desktop. If the .tsep requires a shortcut, instructions about adding the shortcut manually will be added to the installation log. |
TTSD-48024 |
Tools and components |
Previously, the Applications & components catalog could stop responding to mouse clicks if you pressed the Home or End key while using the catalog. You could not select any groups or items in the catalog, for example. This has now been fixed. |
TSAC-6009 |
Import, export, interoperability (concrete) |
Export Unitechnik (79): Previously, in some cases, the line attribute override from surface object applied into an incorrect concrete edge when the object faces were complex. This issue has now been fixed. |
TSAC-6026 |
Import, export, interoperability (concrete) |
Export EliPLAN file (68): The data conversion file can now be read from the XS_FIRM and XS_PROJECT folders. Export Unitechnik (79): The special export assembly file names and reinforcement definition file can now be read from the XS_FIRM and XS_PROJECT folders. |
TSAC-6027 |
Import, export, interoperability (concrete) |
Export Unitechnik (79): Previously, mesh turned to pallet plane failed with some mesh within stair elements. Also, when you exported multiple cast units with surface objects designated as pallet base, the elements were exported incorrectly. This issue has now been fixed. |
TSAC-6065 |
Import, export, interoperability (concrete) |
Export Unitechnik (79): You can now export iron projection data using the new Iron projection setting on the SLABDATE block data specification tab. The values are automatically determined from reinforcement length that extends outside the element. The Special formwork for embed setting has been renamed to Special formwork for object, and now this setting also works for reinforcement specified by class or by name. |
TSAC-6094 |
Import, export, interoperability (concrete) |
Export ELiPLAN file (68): Previously, weep holes were exported incorrectly when hollowcore was cut by its longer side. This issue has now been fixed. |