XS_DRAWING_PLOT_FILE_NAME_A
Category in Advanced options dialog: Printing
Use this advanced option to define print file names for assembly drawings. This advanced option also affects how the exported DWG/DXF/DGN files are named.
Enter any combination of text and options:
|
Value |
Example of the result in the print file name |
Description |
|---|---|---|
|
|
P_1 |
Part, assembly, or cast unit position, using the file name
format |
|
|
P-1 |
Part, assembly, or cast unit position, using the file name
format |
|
|
P1 |
Part, assembly, or cast unit position, using the file name
format |
|
|
2 |
Drawing revision number. |
|
|
B |
Drawing revision mark. |
|
|
PLATE |
Drawing name from the drawing properties dialog. |
|
|
Painted |
Value of a user-defined drawing attribute, f For example,
|
|
|
2 - Rev |
Adds conditional prefixes. In this example, if The question mark
(?) can be used for querying if a |
|
|
Base plate |
You can use template attributes that can be found in Template Editor. The actual values for these attributes are entered in the drawing properties dialog. Examples:
|
This advanced option is role specific. When the type SYSTEM(ROLE) is in use, the default value is used. When the type MODEL(ROLE) or DRAWING(ROLE) is in use, you can change the value, which is then the same for all users in the current model.
Example
The example below results in the assembly drawing PDF name E_P1_PLATE_Revision=2.pdf:
E_%NAME.%_%TITLE%%REV?_Revision=%%REV%
E = is the text you want to have in the
beginning.
NAME. = P1, which is the
part position without punctuation.
TITLE = PLATE, which is the
name that you have entered in the Name box in drawing properties.
REV? = Empty, if there are
no revisions. If a revision exists, the text after the question mark (?) together
with the revision value according to the revision information defined in Rev.No. in the Revision handling dialog are written in the plot file name.
Revision= is the text to be
printed, if REV gives a value. If REV does not give a value,
the text Revision=
will not be printed.
REV = 2, because 2 is the
revision number in the Revision handling dialog.
The print file name switches
%DRAWING_NAME%
and %NAME% that
should produce an underscore in the print file name (P_1) do not work if XS_ASSEMBLY_POSITION_NUMBER_FORMAT_STRING does not use a
separator between the values (for example, %ASSEMBLY_PREFIX%%ASSEMBLY_POS%), or if XS_USE_ASSEMBLY_NUMBER_FOR is set.
To make the switches work, do the following:
- If you want to use
XS_ASSEMBLY_POSITION_NUMBER_FORMAT_STRING, use a dot (.) slash (/) or hyphen (-) between the values, for example,%ASSEMBLY_PREFIX%.%ASSEMBLY_POS%, or similar. - Leave
XS_USE_ASSEMBLY_NUMBER_FORempty.
When you define a switch in the
Advanced options dialog, you only use single percent signs around the switch %xxx%. When you
define a switch for an advanced option in an .ini file, you need to use double percent signs around the switch
%%xxx%%. For example, type %%BOLT_NUMBER%%*D%%HOLE.DIAMETER%% for the advanced option XS_BOLT_MARK_STRING_FOR_SIZE when you define it in an .ini file.