Overview of one-way and two-way load decomposition

Tekla Structural Designer
2020
Tekla Structural Designer

Overview of one-way and two-way load decomposition

The way in which Tekla Structural Designer decomposes panel loads depends on how the slabs/panels are modeled and how they are spanning.

Slab/Panel type Decomposition
One-way spanning slab item

Tekla Structural Designer 1-way decomposes panel loads applied to the slab directly on to those supporting members/two-way spanning slab edges before performing 3D analysis.

The rotation angle of the slab item determines the decomposition direction.
Note: Any openings in 1 way slabs are ignored and thus have no impact on load decomposition.
Roof panel

Tekla Structural Designer 1-way decomposes panel loads directly on to supporting members/two-way spanning slab edges before performing 3D analysis.

The rotation angle of the roof panel determines the decomposition direction.

Two-way spanning slab item
  • At those levels where the Mesh 2-way Slabs in 3D Analysis option is selected, load decomposition is not required.

  • At other levels, any loads applied to two-way slabs are automatically 2-way decomposed back to supporting members during the 3D pre-analysis stage, immediately prior to the 3D analysis stage.

Note: Where openings have been defined, any portion of a panel load that lies within the opening will not be decomposed.
Roof panel overlapping a one-way spanning slab item

Tekla Structural Designer 1-way decomposes panel loads applied to the slab directly on to supporting members/two-way spanning slab edges before performing 3D analysis.

The rotation angle of the slab item (and not the roof panel) determines the decomposition direction.

Note: Any openings in 1 way slabs are ignored and thus have no impact on load decomposition.
Roof panel overlapping a two-way spanning slab item
  • If there are no openings in the slab, decomposition is as per Two-way spanning slab item type described above.
  • Where openings exist, any panel load applied inside the opening is first one-way decomposed in the direction defined by the rotation angle of the roof panel on to the two-way slab at the edge of the opening. It is then further decomposed back to supporting members as per Two-way spanning slab item type described above.
    Note: This does not apply when the panel load is an area load that has been applied to the slab item (as opposed to the roof panel), or a level load, or a slab load. In each of these instances the load will automatically be boxed out around the opening.
这些内容是否有用?
上一步
下一步