XS_BOLT_DUPLICATE_TOLERANCE

Tekla Structures
2022
Tekla Structures

XS_​BOLT_​DUPLICATE_​TOLERANCE

Category in Advanced options dialog box: Numbering

Note:

Do not use this advanced option in new models. This advanced option was part of a temporary solution that has been replaced with a more comprehensive option.

Instead of the XS_BOLT_DUPLICATE_... advanced options, use the No hole option for Special hole type in the Bolt properties.

If necessary in existing models, when XS_​BOLT_​DUPLICATE_​IGNORE is set to TRUE, use XS_BOLT_DUPLICATE_TOLERANCE to set the location tolerance that defines which bolt holes are considered duplicates and will therefore be ignored in part numbering.

The default value for the tolerance is 3 mm.

Note:

It is not recommended to change this advanced option during a project, but if you do so, you must carry out full numbering.

This advanced option is model specific and the setting is saved in the options database.

Was this helpful?
Previous
Next