Solver element (2D) types

Tekla Structural Designer
2021
Tekla Structural Designer

Solver element (2D) types

Three 2D solver element types are available and applied in Tekla Structural Designer as follows:

Shell

Shell elements are used for the following slabs and decks when meshed, provided they are two way spanning and their diaphragm option is not set to Semi-rigid:

    • Flat slab,
    • Slab on beams,
    • Steel deck,
    • Timber deck,
    • General deck,
    • Foundation mat

SemiRigid

SemiRigid elements are used for the following slabs and decks when meshed, if their diaphragm option is set to Semi-rigid:

    • Flat slab,
    • Slab on beams,
    • Steel deck,
    • Timber deck,
    • General deck,
    • Foundation mat

Wall

Wall elements are used for walls when the Wall Type is set to Meshed Shear Wall, i.e.

    • Concrete Meshed Shear Wall,
    • General Meshed Shear Wall
Was this helpful?