Review and modify user defined U/R

Tekla Structural Designer
2020
Tekla Structural Designer

Review and modify user defined U/R

From a Review View you can graphically review user defined utilization ratios, set the members to which they are applied, and set whether they apply to autodesign alone, or both autodesign and check.

Review user defined U/R

  1. Open a view and change the view regime to Review View.
  2. On the Review toolbar, click Show/Alter State.
  3. Go to the Properties window.
  4. In the Attribute list, select User defined U/R.

Apply a user defined U/R for autodesign only

  1. Open a view and change the view regime to Review View.
  2. On the Review toolbar, click Show/Alter State.
  3. Go to the Properties window.
  4. In the Attribute list, select User defined U/R.
  5. Set Mode to Apply to Autodesign.
  6. Select Set limit ratio.
  7. Specify the required Ratio limit
  8. If required, set Entity type and Material to make the command easier to apply.
  9. In the model, click those column/wall stacks, beam spans, or objects for which you want to apply the user defined U/R.
  10. Continue setting the limit by clicking the desired columns and walls or press Esc to finish.

Apply a user defined U/R for autodesign and check

  1. Open a view and change the view regime to Review View.
  2. On the Review toolbar, click Show/Alter State.
  3. Go to the Properties window.
  4. In the Attribute list, select User defined U/R.
  5. Set Mode to Apply to Autodesign+Check.
  6. Select Set limit ratio.
  7. Specify the required Ratio limit
  8. If required, set Entity type and Material to make the command easier to apply.
  9. In the model, click those column/wall stacks, beam spans, or objects for which you want to apply the user defined U/R.
  10. Continue setting the limit by clicking the desired columns and walls or press Esc to finish.

Turn off user defined U/R

  1. Open a view and change the view regime to Review View.
  2. On the Review toolbar, click Show/Alter State.
  3. Go to the Properties window.
  4. In the Attribute list, select User defined U/R.
  5. Set Mode to Set Off.
  6. If required, set Entity type and Material to make the command easier to apply.
  7. In the model, click those column/wall stacks, beam spans, or objects for which you want to turn off user defined U/R.
  8. Continue by clicking the desired stacks/spans/objects or press Esc to finish.
Was this helpful?