Roof panel types

Tekla Structural Designer
Изменено: 6 сен 2023
2024
Tekla Structural Designer

Roof panel types

For wind loading calculations it is important that the correct roof type has been assigned to each roof panel, the following RoofType choices being available.

RoofType Example

Default

(if roof slope < 5 degrees)

and

Flat

Default

(if roof slope ≥ 5 degrees)

and

Monopitch


Duopitch
Hip Gable
Hip Main
Mansard

For snow loading calculations, Tekla Structural Designer only has to distinguish between monopitch and pitched roofs. This is determined from the RoofType as follows:

RoofType For snow loading this is considered as:
Default Monopitch
Flat Monopitch
Monopitch Monopitch
Duopitch Pitched
Hip Gable Pitched
Hip Main Pitched
Mansard Pitched