XS_OMITTED_WELD_TYPE
Category in Advanced options dialog: Welds
Use this advanced option to define which weld type to omit in
drawings. Enter the number of the weld type you want to omit. The default value is
10 (fillet weld).
For more information about the weld types and the corresponding numbers, see List of weld types.
In addition to this advanced option,
there are two other settings that Tekla Structures uses to determine the
welds that are shown in the drawing: XS_WELD_FILTER_TYPE tells if
Tekla Structures should filter welds that are exactly the size (EXACT) or of the same size
or smaller (MIN)
than the value given in the Weld size limit box in the object or mark properties on the drawing view level. Tekla Structures always shows welds that have reference text.
This advanced option is model specific and the setting is saved in the options database.
Example
If you set
XS_OMITTED_WELD_TYPE to 10,
XS_WELD_FILTER_TYPE to
EXACT, and
Weld size limit to 5,
Tekla Structures shows all other welds except those that are 5 mm, and those of type fillet weld (10). In this case, if you do not set
XS_WELD_FILTER_TYPE,
Tekla Structures shows all welds that are bigger than 5 mm except fillet welds.