TSAC-7703 |
Concrete components |
Floor layout: Polygon cuts now get the names from the cut parts. |
TSAC-7782 |
Concrete components |
Rectangular column reinforcement (83): Intermediate links were sometimes created with wrong end condition attributes (angle/radius/length). This issue has now been fixed. |
TSAC-7861 |
Concrete components |
Wall layout: Previously, in some cases, cuts were not created correctly when the contour of the wall layout was changed. This issue has now been fixed. |
TSAC-7954 |
Concrete components |
Tapered I-beam (81): Previously, the beam was incorrectly cut at the start and at the end. This issue has now been fixed. |
TSAC-6321 |
Steel components |
Metsec Side rail supports (28): Assembly prefix and position number have been added for the tie wires. |
TSAC-6524 |
Steel components |
Haunch (40): Previously, when the Extra length for haunch flange plate option on the Parameters tab was left empty, 0.0 was written to the Shorten user-defined attribute. This issue has now been fixed and UDA is empty. |
TSAC-6826 |
Steel components |
Metsec Standard riveted channel rails (37): The RCR Profile type list has been updated. New G grade sections have been added at the end of the list. |
TSAC-7260 |
Steel components |
Joist to column, type 2 (163): Previously, a bearing plate was created only for seats with an angle profile type. This issue has now been fixed. |
TSAC-7458 |
Steel components |
Column - 2 beams (14): Previously, when the secondary parts were sloped, the component could cause errors in the main part creation. This issue has now been fixed. |
TSAC-7760 |
Steel components |
Tube gusset (20): Previously, the Finish property was not correctly applied on the gusset plate when the gusset plate was created through the main part. This issue has now been fixed. |
TSAC-7775 |
Steel components |
Steadmans Non-std anti-sag (57), Steadmans Anti-sag system (53): The hole modeling error when using the anti-sag ties has now been fixed. |
TSAC-7841 |
Steel components |
CMF Cold rolled sleeved (120): The default bolt size is now 18 mm. The option to select bolt size has been removed. |
TSAC-7843 |
Steel components |
CMF Diagonal ties (55): Diagonal wires now place 18 mm diameter fixing holes. |
TSAC-7863 |
Steel components |
UltraZED Cold rolled sleeved (107): The Orientation hole option has been added on the Parameters tab. |
TSAC-7889 |
Steel components |
Kingspan File transfer (18): Exploded DA type tie wires are now flagged in the error log. |
TSAC-7900 |
Steel components |
CMF Standard horizontal cladding support (31): The location of intermediate wires has been fixed to the sheeting face. Wires at column position have been fixed to the hole nearest the column face. |
TSAC-7904 |
Steel components |
CMF Window trimmer rail (37): Holes are now allowed on gauge lines on the window trimmer strut. |
TSAC-7905 |
Steel components |
CMF Window trimmer rail (37): Bolted cleat option is now available on the Parameters tab. |
TSAC-7906 |
Steel components |
CMF Window trimmer rail (37): When picking the position of the window trimmer, you can now pick a position on the channel edge. Previously, you could only use the bolt position to pick the position. |
TSAC-7913 |
Steel components |
Kickplate (S75): Previously, welds 1 and 2 were not created correctly. This issue has now been fixed. |
TSAC-7920 |
Steel components |
Spiral stair (S68): Previously, offset from the top of the stair to the top of the sleeve was not working correctly when stairs were created clockwise. This issue has now been fixed. |
TSAC-7933 |
Steel components |
Kingspan Mezzanine file transfer (19): Previously, KC sections were removing valid holes from the CAM data. This issue has now been fixed. |
TSAC-7935 |
Steel components |
Kingspan Mezzanine file transfer (19): Countersunk bolts are now flagged as invalid in the CAM data. |
TSAC-7944 |
Steel components |
Bolted cap plate (27): Previously, bolt holes in the cap plate were not adjusted correctly for one secondary part. This issue has now been fixed. |
TSAC-7953 |
Steel components |
Metsec File transfer (26): The tolerance for apex strut has been increased to 1 mm in the X direction. If it is greater than 1 mm, a drawing will be requested. |
TSAC-7962 |
Steel components |
Tube gusset (20): Previously, chamfers were not created correctly in the end plate. This issue has now been fixed. |
TSAC-7963 |
Steel components |
Tube crossing (22): Previously, chamfers were not correctly created in the end plate. This issue has now been fixed. |
TSAC-7969 |
Steel components |
Cold rolled overlap (1): Previously, positioning of bolts did not work and the bolt group was not created correctly. This issue has now been fixed. |
TTSD-57247 |
Import, export, interoperability |
Point clouds: Point clouds now support files from Trimble X9 3D Laser Scanning System. |
TTSD-57796 |
Import, export, interoperability |
Export model to other formats: Sometimes models were freezing when you tried to export the model to an external format or upload the model to Trimble Connect. This issue has now been fixed. |
TTSD-58150 |
Import, export, interoperability |
Drawing DWG export: Hatches now work more reliably when you use a basepoint in the export. |
TTSD-58312 |
Import, export, interoperability |
IFC2x3 export: When exporting a surface with multiple holes, the exported geometry was wrong. This issue has now been fixed. |
TTSD-58637 |
Import, export, interoperability |
Reference models inserted from the Trimble Connect: The reference models in the Reference object list in drawings now show the downloaded time from Trimble Connect. |
TTSD-58963 |
Import, export, interoperability |
IFC2x3 export: The export now adds workshop polygon welds to the assembly they belong to. |
TTSD-58988 |
Import, export, interoperability |
Trimble Connect: Project UDA for pour objects is now exported to .tekla files and uploaded to Trimble Connect. |
TTSD-59098 |
Import, export, interoperability |
Import from Tekla Structural Designer: The rotation angle for portal columns was not correct in Tekla Structures after importing a Tekla Structural Designer model in .tsmd format (not .cxl ), unless the frame in Tekla Structural Designer was parallel to the global X axis. This issue has now been fixed. |
TTSD-59145 |
Import, export, interoperability |
Trimble Connect: When clicking For Browser >3D View, the project explorer should have been opened instead of a 3D view if an error occurred during the upload of the model, or if no models were uploaded. This issue has now been fixed. |
TTSD-59183 |
Import, export, interoperability |
IFC4 export: Rebar assemblies are now exported also when you use IFC4Precast View. |
TPLED-303 |
Templates and reports |
Template Editor: Sometimes, targeting a value field in a hidden row with a CopyField function did not work. This issue has now been fixed. |
TTSD-36054 |
Templates and reports |
Templates and reports: Earlier, sawing angles in reports were sometimes reported incorrectly for short profiles. This issue has now been fixed. |
TTSD-52669 |
Drawings |
Snapping in drawings: When creating several reference points with numerical input in drawings, creating more than 2 points could lead to unpredictable results. This has now been fixed. |
TTSD-55379 |
Drawings |
Fabrication drawings: The Creation review dialog box was listing some setting files that were not drawing setting files. This issue has now been fixed. |
TTSD-57507 |
Drawings |
Clone selected: Previously, when a mark had a template as the content, the template values did not change when you cloned the marks to new objects, and you had to update the marks manually. Now the values are updated automatically. |
TTSD-58238 |
Drawings |
Integrated dimensions: The missing dimension grouping support has been added to the drawing creation. |
TTSD-58689 |
Drawings |
Very rarely, when changing the drawing selection while printing drawings, Tekla Structures stopped responding. This issue has now been fixed. |
TTSD-59147 |
Drawings |
Tekla Structures sometimes stopped responding on drawing opening if the name of the drawing was too long. This issue has now been fixed. |
TTSD-59186 |
Drawings |
Adding marks in drawings now works more reliably in cases where the marks previously where defined as to have no content. |
TTSD-59619 |
Drawings |
Fabrication drawings: Tekla Structures stopped responding while trying to get dimensioning attributes from subfolders. This issue has now been fixed. |
TTSD-59942 |
Drawings |
Tekla Structures sometimes stopped responding when you were modifying a drawing with complex parts. This issue has now been fixed. |
TTSD-56946 |
Reinforcement |
Rebar sets: When you change the bar size using the contextual toolbar for property modifiers, the bar sizes are now sorted correctly. |
TTSD-58916 |
Reinforcement |
In some cases, large coordinates for base points reduced the accuracy of bending shape rule calculations in rebar shape recognition, which sometimes produced incorrect results. This issue has now been fixed. |
TTSD-56637 |
Modeling |
Previously, filters with multiple values (for example, filtering bolts with multiple sizes) were not correctly saved and loaded. This has now been fixed. |
TTSD-59227 |
Modeling |
Previously, when you interrupted a command, the X/Y/Z coordinate lock was released, but the lock symbol in the status bar was not cleared. This has now been fixed. |
TTSD-59892 |
Modeling |
Now the Toggle coordinate lock Y command is again available in the Keyboard shortcuts dialog box. Previously, the command was missing from the dialog box. |
TTSD-59354 |
Installation |
Previously, Tekla Structures sometimes did not start after installing Windows updates. This issue has now been fixed. |
TTSD-59431 |
Tools and components |
Trimble Connect Visualizer has been updated to a newer version.
The new version fixes the following:
- fix for gamepad not being able to look directly down
- fix for Tekla Structures rebar endings
- bird eye view/back of the model with F5
- fix for visual tweaks panel loading incorrect settings in some environments. |
TTSD-40505 |
User interface |
Now, on the Tekla Structures start screen, the list of models is resized correctly. Previously, all the columns were not shown. |
TTSD-59865 |
User interface |
When you now open Tekla Structures for the first time, no environment is selected by default. Instead, a Select Environment text is displayed in the Environment selection list. Once you have selected an environment, Tekla Structures always uses the last selected environment as the default one. |
TSAC-7844 |
Import, export, interoperability (steel) |
DSTV to DXF converter: No selected text options were added after converting a file without any added text. This issue has now been fixed. |
TTSD-50250 |
Import, export, interoperability (steel) |
DSTV/NC: Earlier, sawing angles were not reported in the NC files when you exported a short profile. Now the sawing angles are reported also for short profiles. |
TTSD-56129 |
Import, export, interoperability (steel) |
DSTV/NC export: When you exported geometry with notches, unusually large coordinates might sometimes appear in the AK contour. This issue has now been fixed. |
TTSD-59128 |
Import, export, interoperability (steel) |
DSTV/NC: Earlier, when you used the DSTV export for L profiles, through holes could be created on top or bottom profile faces, causing missing holes in certain viewers. Now the BO block for these holes is always created on the bottom face. |
TTSD-59890 |
Import, export, interoperability (steel) |
DSTV/NC: Previously, contour marking filters in the NC export were not working correctly. This issue has now been fixed. |
TSAC-7959 |
Import, export, interoperability (concrete) |
Export ELiPLAN file (68): Previously, plotter data was missing for elements when the position number type was set to ACN. This issue has now been fixed. |
TSAC-7971 |
Import, export, interoperability (concrete) |
Export ELiPLAN file (68): Previously, the Plot cutout/embed as lines filtering did not work correctly. This issue has now been fixed. |
TSAC-7972 |
Import, export, interoperability (concrete) |
Export ELiPLAN file (68): Previously, plotted additional reinforcement was missing height, width, or thickness in some cases. This issue has now been fixed. |
TTSD-59615 |
Common |