2019 SP5: New features and improvements
2019
Tekla Structures
Poprawki
Numer defektu | Obszar rozwoju | Opis |
---|---|---|
TSAC-2359 | Steel components | In U.S. Base plate (1047), in some situations, two anchors were previously added to the same assembly. This has now been fixed. |
TSAC-2470 | Import, export, interoperability (concrete) | Export Unitechnik (79): Previously, when a double wall shell was created from more than one part and the Cut outer assemblies option was switched on, the embeds in the secondary part were missing from the export with certain Export Groups settings. This has now been fixed. |
TSAC-2594 | Import, export, interoperability (concrete) | Export EliPlan file (68): When using the Export using filter setting, the logging of excluded cast units has been improved. |
TSAC-2680 | Steel components | Previously, Metsec side rails were wrongly being reported as riveted C rails. This has now been fixed. |
TSAC-2734 | Concrete components | The Update rebar attributes tool now has a new Update (phase only) button with which you can update just the phase of all rebar coupler/end anchor parts. The existing Update button still functions as before. You can use the Update button to update the coupler/end anchor-specific UDA values in addition to the phase of coupler/end anchor parts. |
TSAC-2878 | Steel components | UltraZED Cold rolled sleeved (107): When using a ULT-AB1 profile as the stay cleat profile, the stay was not created correctly. This has now been fixed. |
TSAC-3171 | Import, export, interoperability (concrete) | Export Unitechnik (79): On the TS configuration tab you can now set Export CONTOUR to Simplified, which exports a simplified contour using 4 x,y corner points of the element. |
TSAC-3178 | Drawings | Rebar group dimensioning: The start value of absolute dimensions is now shown correctly again in the Rebar group dimensioning application. |
TSAC-3189 | Import, export, interoperability (concrete) | Export EliPlan file (68): A new tab Data settings was added, and some settings were moved to the new tab from the Data content tab. |
TSAC-3191 | Import, export, interoperability (concrete) | Export EliPlan file (68): EliPlan export now supports export version 3.0 (FloorMES). |
TSAC-3192 | Import, export, interoperability (concrete) | Export Eliplan file (68): The export now supports export of weep holes in version 3.0. |
TSAC-3193 | Import, export, interoperability (concrete) | Export EliPlan file (68): The export now supports the export of accessory code to plotter data in version 3.0. |
TSAC-3194 | Import, export, interoperability (concrete) | Export EliPlan file (68): The new EliPlan export version 3.0 supports the export of stack results. You can select if the UDA is read from the main part or from the cast unit. |
TSAC-3269 | Import, export, interoperability (concrete) | Export EliPlan file (68): It is now possible to specify a UDA to read the strand code. Default reads the value from the TS_STRAND_CODE UDA. |
TSAC-3368 | Steel components | Splice type 1 (56): The Round web plate dimensions option on the Parameters tab now works correctly. |
TSAC-3398 | Concrete components | Lifting anchor (80): You can now select to allow anchor distribution based on percentage of the length. |
TSAC-3420 | Import, export, interoperability (concrete) | Export EliPlan file (68): Plotter data for cuts and recesses exported as lines will have the thickness/depth value, in case the cut is of even depth. |
TSAC-3428 | Reinforcement | Rebar shape manager has been changed so that a bar that contains multiple sequential bends forming a circular arc (according curve tolerance) is converted to an arc only when the bending angles are smaller than ~34 degrees. In practice, a 10-sided polygonal stirrup will never be converted to a circular arc but if the stirrup contains 11 or more sides, it may be converted to a circular arc if it fulfills the curve tolerance value. |
TSAC-3440 | Steel components | Previously, Metsec RoundLok anti-sags were incorrectly creating bolts rather than holes. This has now been fixed. |
TSAC-3454 | Drawings | Rebar group dimensioning: The tool now takes the view depths into account to determine the part shape. Previous only the view plane was used. |
TSAC-3466 | Concrete components | Precast foundation block (1028): You can now define angles for grooves on the Grooves tab. |
TSAC-3484 | Import, export, interoperability (concrete) | Export Unitechnik (79): Previously, braced girders within the STEELMAT block were not exported when the STEELMAT block was otherwise empty. This has now been fixed. |
TSAC-3488 | Import, export, interoperability (concrete) | Export Unitechnik (79): Braced girders modeled with only two chords are now correctly recognized and exported. |
TSAC-3513 | Concrete components | Anchor (10): The top and bottom offsets were incorrectly calculated for parts with complex parametric profiles and parts that have been cut. This has now been fixed. |
TSAC-3518 | Import, export, interoperability (concrete) | Export Unitechnik (79): When the BRGIRDER block is exported within the STEELMAT block, the STEELMAT insertion coordinates are now correctly adjusted in case the girder minimum coordinate points are outside the mesh. |
TSAC-3521 | Import, export, interoperability (concrete) | Export EliPlan file (68): The Tag for lifters setting has been improved and now also rebars can be specified as lifters using class or name. Now Tag for lifters also has option to specify how the lifters geometry should be plotted - as outline or as center point. It is also possible to specify plotting of additional reinforcement as bounding box or as lines using the setting Plot additional reinforcement or Plot cutout/embed as lines. |
TSAC-3522 | Import, export, interoperability (concrete) | Export EliPlan file (68): Export version 3.0 supports the export of accessory code for openings. |
TSAC-3523 | Concrete components | Concrete console (111): Assembly type is now correctly loaded. |
TSAC-3524 | Concrete components | Concrete beam-beam (112): The box used for defining the length of the first washer on the Anchors tab is now dimmed properly. |
TSAC-3525 | Import, export, interoperability (concrete) | Export EliPLAN file (68): Recesses that cut the complete area of the element are now plotted. |
TSAC-3531 | Steel components | Brace middle tubes and plate (144): Connection plates are now bolted to the gusset plate in the correct order. |
TSAC-3536 | Steel components | Tube gusset (20): Previously, both above and below line welds were created as above line welds. This has now been fixed. |
TSAC-3541 | Import, export, interoperability (concrete) | Export Unitechnik (79): The Extend contour and add formwork option on the TS configuration tab has been improved. Now, formwork is not added if there is already an embed with the same geometry. Also, the contour is not extended for electric tube embeds. |
TSAC-3543 | Import, export, interoperability (concrete) | Export Unitechnik (79): The Double wall turned setting on the TS configuration tab has been improved. The No option has been renamed to option No, one coordinate system and new option No, shell-specific coordinate systems has been added to export second shell in the Z direction from the bottom of the pallet upwards. |
TSAC-3555 | Import, export, interoperability (concrete) | Export Unitechnik (79): Previously, when you exported braced girders within the STEELMAT block but with mesh filtered out, the reinforcement block was exported as empty. This has now been fixed. |
TSAC-3556 | Concrete components | Embedded anchors (8): Previously, only concrete parts have been taken into calculations when using the Assembly without steel parts option on the Placement tab. This has now been fixed and miscellaneous parts are also considered. |
TSAC-3569 | Concrete components | Two sided seating with dowel (76): The drainage hole is now generated properly around custom parts. |
TSAC-3587 | Concrete components | The Wall layout dialog box now supports high-resolution screens with high scaling. |
TSAC-3592 | Import, export, interoperability (concrete) | Export Unitechnik (79): Electric tubes are now not excluded for the whole length when you use the Cut outer assemblies option together with non-turned double walls. |
TSAC-3595 | Concrete components | Concrete console (110): The cast unit numbering standard is now loaded and saved properly for all parts. |
TSAC-3602 | Concrete components | Concrete console (110): Previously, incorrect extra secondary parts were found when you defined them using the class or name. This has now been fixed. |
TSAC-3656 | Import, export, interoperability (concrete) | Export Unitechnik (79): Previously, line attributes were not exported for second shell of the double wall when Double wall turned was set to No, shell-specific coordinate systems on the TS configuration tab. This has now been fixed. |
TSAC-3693 | Steel components | Brace corner tubes and plate (44): Connection plates are now bolted to the gusset plate in the correct order. |
TSAC-3704 | Import, export, interoperability (concrete) | Export EliPlan file (68): Previously, full depth cuts placed at hollow core profile chamfer lines with certain profiles were exported with incorrect geometry. This has now been fixed. |
TSAC-917 | Steel components | Angle profile box (1040): Upper stiffener thickness, width and height are now correctly applied. |
TTSD-17311 | Import, export, interoperability | IFC2x3 export: The export type Coordination view 2.0 did not always create correct geometry for contour plates with corner chamfers. This has now been fixed. |
TTSD-19815 | Drawings | The Document manager error handling has been improved. Now a message is shown if there is a problem reading any of the saved settings files. |
TTSD-21410 | Tools and components | Outdated locked custom part instances are no longer automatically updated when they or their objects are unlocked. Outdated custom parts are updated to use the latest definition with modify when the custom part or its objects are not locked anymore. |
TTSD-22549 | Import, export, interoperability | DWG export: When exporting a drawing to DWG, part hatch pattern HSTON3E0 looked wrong if the scale was not the same in X and Y directions. This has now been fixed. |
TTSD-25906 | Drawings | The Delete button in Document manager has been improved. Now, if you have selected documents in Document manager, clicking Delete deletes selected documents. You can no longer accidentally delete model objects by clicking Select objects in the model for selected drawings and then clicking Delete. |
TTSD-26477 | Drawings | The rebar dimension line now works better for those rebar groups that do not have a planar shape, such as a 3D shape. |
TTSD-27133 | Tools and components | The Shape value type is now available in the custom component editor. You can use it to open the shape catalog from the custom component dialog box. You can use the new value type in existing custom components that include items by editing the components. |
TTSD-2741 | Drawings | "ą" diacritics could not be used in drawing text window - using shortcut for this letter selected entire text. This has now been fixed. |
TTSD-27794 | Drawings | Part marks with the Fittings (NS/FS) element can now be merged more reliably. |
TTSD-27826 | Modeling | In some cases, for example, when the plane of a part face or an opening face ran through an opening in the part and its pour break plane, the pour break was not created or it became invalid. This has now been fixed. |
TTSD-28033 | Import, export, interoperability | IFC export: The grids were exported incorrectly if you used a base point in the export. This has now been fixed. |
TTSD-28999 | Import, export, interoperability | DWG export: The export now handles base point offsets better. |
TTSD-29764 | Drawings | Inquiring a rebar set from within a drawing did not highlight the corresponding bars in the model. This has now been fixed. |
TTSD-29843 | Modeling | Previously, it was not possible to enter the decimal symbol after the inch symbol when defining radial grid properties in the property pane or when using the Radial grid component. This has now been fixed and you can enter values in the format 1'-2".5 , 1-2".5 , or just 2".5 . |
TTSD-29844 | Modeling | Previously, it was not possible to enter the decimal symbol after the inch symbol when defining rectangular grid properties in the property pane. This has now been fixed and you can enter values in the format 1'-2".5 , 1-2".5, or just 2".5 . |
TTSD-29882 | Import, export, interoperability | DWG export: When exporting a drawing in US imperial environment, the preview window width was sometimes not enough to show the whole drawing. This has now been fixed. |
TTSD-30725 | Organizer | In Organizer, project properties were not previously exported to Excel. This has now been fixed. |
TTSD-30812 | Drawings | In some cases rebar mark was incorrectly placed. This has now been fixed. |
TTSD-30862 | Drawings | Sometimes precast parts with more than 500 edge lines were incorrectly shown in drawing views. This has now been fixed, |
TTSD-30924 | Import, export, interoperability | DWG export: The export is now more reliable when plotting pull-out pictures in templates. |
TTSD-31129 | Import, export, interoperability | IFC2x3 export: The property set mapping double accuracy type is now working correctly, and the size of the export file is reduced. |
TTSD-31166 | Drawings | Opening general arrangement drawings that were created in Tekla Structures versions older than 2017 is now faster. |
TTSD-31350 | Organizer | Previously, synchronization in Organizer was cancelled when the selection in the model was changed. This has now been fixed. |
TTSD-31360 | Import, export, interoperability | DWG export: The export now launches a bit faster than before. |
TTSD-31361 | Drawings | In some cases, when a GA drawing view was created with certain view settings, it would behave incorrectly when you adjusted the view frame. This has now been fixed. |
TTSD-31395 | Modeling | Certain types of pour breaks now work on slabs with recesses. |
TTSD-31430 | Import, export, interoperability | DWG export: The export is now more robust when the Educational license is in use. |
TTSD-31525 | Licensing | The error message for an expired Tekla Structures license has now been fixed. |
TTSD-31938 | Drawings | When moving views from one drawing to another, some dimensions were sometimes rotated a bit. This has now been fixed. |
TTSD-32086 | User interface | The contextual toolbar now loads the previously used contextual toolbar profile when Tekla Structures is started even if the profile file is saved in the firm folder. The firm folder location needs to be defined in the teklastructures.ini file. |
TTSD-32668 | User interface | Previously, Tekla Structures sometimes crashed when you tried to drag a floating side pane window or the changes list. This has now been fixed. |