Lijst met oplossingen van Tekla Structures in 2023

Tekla Structures
2023
Tekla Structures

Lijst met oplossingen van Tekla Structures in 2023

Tekla Structures 2023 bevat alle fixes uitgebracht in Tekla Structures 2022 Service Packs tot en met SP7. Deze fixes worden niet in de fixlijst Tekla Structures 2023 opgenomen.

Oplossingen

Nummer defect Ontwikkelingsgebied Beschrijving
TSAC-3772 Concrete components


Formwork placing tools - Walls: On the Conditions tab, when a new sub-condition is created it is automatically selected in the drop down list in the wizard.

TSAC-6856 Concrete components

Floor layout: The Line up direction setting on the General tab now works correctly. Previously, if you had the insulation layer as the lower layer and changed the line up direction, the insulation was not created correctly.
 

TSAC-6904 Concrete components

Starter bars for footing (87) now takes the local plane of the pad footing into account. Previously, the global orientation was taken into account, and this caused rotated pad footings with starter bars to have different numbering.

TSAC-6950 Concrete components

Mesh bars, Mesh bars by area: When the cover thickness values for the openings or recesses by cuts are not defined, the cover thicknesses for rebar ends defined on the Bar end condition tab are used instead.
When none of the cover thickness values are defined, the default cover thickness is used.

TSAC-7019 Concrete components

Floor layout: The CIP filler part is no longer created outside the component polygon boundaries.

TSAC-2695 Steel components

Metsec File transfer (26): Metsec apex strut CAM data is improved to allow for situations when purlins are set between or below the rafters.

TSAC-4476 Steel components

 

Stiffeners (1034): Previously, the welds between the stiffeners and the part were created in an incorrect position. This issue has now been fixed.

TSAC-6532 Steel components

Metsec Horizontal cladding support column (33): Metsec CAM data for the horizontal cladding connection at the column has been updated to correct the cleat positions shown in the CAM.

TSAC-6696 Steel components

CMF Mezzanine floor connection (149): Weld settings are no longer available in the component dialog box.

TSAC-6726 Steel components

Kingspan Standard tie bay (10): Previously, when using the component, the hole in the top CSC was not applied. This issue has now been fixed.

TSAC-6739 Steel components

Welded to top flange (147), Full depth (184): The assembly numbering prefix and start number now correctly use the default value defined in Settings > Options > Components.
 

TSAC-7042 Steel components

Joining plates (14): Previously, galvanizing holes were not created correctly in the second end plate. Now sinkholes are created into all end plates.

TSAC-7109 Steel components

Gusset+ T: The stiffener chamfer is now created to the web of the main part.

EPM-6996 Import, export, interoperability

Export to Tekla PowerFab: When assembly marks in Tekla Structures were split by phase, the drawings could get mismatched. This issue has now been fixed.

TTSD-53619 Import, export, interoperability

Reference models: The occasional problem causing freezing and black screen when using face picker with complex reference model objects, especially when rotating the model, has now been fixed.

TTSD-53542 Templates and reports

Previously, template attributes for reinforcements for any value starting with "PHASE." returned the object's phase name. Now the template attributes return the correct value. For example, "PHASE.NAME" returns the phase's name and "PHASE.COMMENT" returns the phase's comment.

TTSD-44775 Drawings

Multi-drawing links were not correctly preserved when drawing was split during numbering. This issue has now been fixed.

TTSD-48119 Drawings

Multi-drawings that have copied views now correctly highlight the objects in the model when you click the Select objects in the model for selected parts button in Document manager.

TTSD-48440 Drawings

Bolts in general arrangement drawings
The following advanced options now work correctly in general arrangement drawings:
XS_DRAW_BOLT_OWN_HIDDEN_LINES_IN_GA_DRAWINGS
XS_DRAW_BOLT_HIDDEN_LINES_IN_GA_DRAWINGS
Previously, changing the bolt representation caused problems.

TTSD-49056 Drawings

Moving views between drawings did not always work correctly. The functionality has now been improved.

TTSD-54894 Drawings

Rebar pull-out pictures: In some cases, planar rebar pull-out pictures were not correctly oriented towards the view. This issue has now been fixed.

TSAC-7022 Reinforcement

In Rebar shape manager, the preview of the selected bar shape did not work properly with 3D bars. The visualization of 3D bars has now been fixed.

TTSD-32757 Reinforcement

Rebar sets: When a rebar set with leg surfaces is copied or moved to a part whose geometry differs from the original part, the leg surfaces now automatically adapt to the geometry of the destination part.

TTSD-37806 Reinforcement

Rebar sets: With the Standard lapping option in the Rebar splitter properties, the lap length of the smaller bar is now used. Previously, the lap length of the larger bar was used.

TTSD-47466 Reinforcement

An issue was fixed where the MATERIAL_TYPE template attribute returned no value in a REBAR_ASSEMBLY row. It now returns REINFORCING BAR.

TTSD-49255 Reinforcement

Rebar sets: Some issues were fixed that caused bar geometry to be incorrectly calculated, so short bar legs were protruding out of rather than into the concrete part.

TTSD-52980 Reinforcement

Rebar coupler related UDAs ending in _START or _END (like METHOD_START) will now swap values if the bar is reversed with respect to the rebar shape definition, similarly as HOOK_START and HOOK_END have done already earlier.

Note that if this issue has been worked around in templates with an "if" statement, that workaround should be removed in Tekla Structures 2023.

TTSD-45752 Modeling

The applied values in the property pane are not reset to standard after multi-user save but they are preserved, in the same way as in the old dialog boxes.

TTSD-48002 Modeling

Previously, modifying non-special UDAs in the property pane could cause the object numbering being marked as not up-to-date in certain cases. This has now been fixed.

TTSD-53609 Modeling

Cast in place parts are now correctly visualized on all zoom levels.

TTSD-55548 Modeling

Bolts: Earlier, in Tekla Structures 2022, if you modeled a bolt that went through two or more parts and that had a negative cut length, the bolt was placed incorrectly. This issue has now been fixed.

TTSD-55968 Modeling

Rebar assemblies: The Locked user-defined attribute has now been added for rebar assemblies.

TTSD-56274 Modeling

Bolts: Earlier, in Tekla Structures 2022, bolts were incorrectly positioned when beams or columns were deformed by shortening. The incorrect positioning occurred when XS_DRAW_BOLTS_3D_IN_BOLT_LAYER was set to TRUE and when the bolts had the Exact representation in model views. This issue has now been fixed.

TTSD-53372 Licensing

Now the dashed hidden lines are shown correctly behind objects, instead of being shown in front in transparent view modes.

TTSD-50645 User interface

Now, when you hover the mouse pointer over side pane window, pressing Ctrl+F1 opens the corresponding help page in Tekla User Assistance.

EPM-6627 Import, export, interoperability (steel)

Export to Tekla PowerFab: DSTV files are now exported in UTF-8 without the byte-order-mark (BOM).

TSAC-6846 Import, export, interoperability (concrete)

Export Unitechnik (79): Previously, double values exported from a UDA were exported with an incorrect number of decimals. This issue has now been fixed.

TSAC-6656 Common

In some cases 2D Library caused Tekla Structures to freeze when running numbering in multi-user mode. This issue has now been fixed.

Was dit nuttig?
Vorige
Volgende