2018i SP9: New features and improvements
2018i
Tekla Structures
Oplossingen
Nummer defect | Ontwikkelingsgebied | Beschrijving |
---|---|---|
TSAC-4346 | Concrete components | Reinforcement mesh array (91): Mesh creation did not work on slabs that contained a great number of notches. This has now been fixed. |
TSAC-3385, TSAC-4340, TSAC-4341 | Concrete components | Concrete foundation (1030) has been improved as follows:
Image
|
TSAC-4405 | Concrete components | Hollowcore reinforcement strands (60) now reads more values of the defined grid from external files. This allows you to add a bigger grid for the strands. This has been improved on the external files side only, and not in the dialog box, because of length limitations. |
TSAC-4435 | Concrete components | Concrete console (110) and Concrete beam-beam (112): Previously, when modifying the components with changes that did not affect numbering, the numbering was changed to not up to date. This has now been fixed. |
TSAC-4531 | Concrete components | Corbel reinforcement (81): The component is now created properly in situations where the corbel is smaller than the column. |
TSAC-4583 | Concrete components | Seating with dowel to flange (77), Two sided seating with dowel to flange (78): The bearing pad no longer collides with the column. |
TSAC-3036 | Steel components | Stiffeners (1034): Previously, the gap between the stiffener and the main part web was incorrectly applied. This has now been fixed. |
TSAC-3977 | Steel components | Cage ladder (S60): You can now define the rotation of the rail bars on the Parameters tab. You can also define the vertical and horizontal offset of bottom supports on the Supports tab. |
TSAC-4179 | Steel components | Two sided end plate (142) & End plate (144): Previously, the horizontal offset of bolts also affected the position of galvanizing holes. This has now been fixed. |
TSAC-4307 | Steel components | Two sided end plate (142): Previously, the welds between the haunch plates and end plates were missing when a secondary part was skewed. This has now been fixed. |
TSAC-4308 | Steel components | Two sided end plate (142): Previously, welds number 1 and 5 were also used to weld haunch plates to the secondary parts. This has now been fixed. |
TSAC-4324 | Steel components | Welded column with stiffeners (128): Previously, the gaps between the stiffeners and main part flanges were not applied correctly. This has now been fixed. |
TSAC-4375 | Steel components | Extend full depth tab (82): Previously, bolts were created incorrectly in some situations. This has now been fixed. |
TSAC-4376 | Steel components | Column with stiffeners W (182): Previously, the weld properties in the component did not match the values set in the dialog box. This has now been fixed. |
TSAC-4398 | Steel components | Shear plate (103): Previously, bolt edge distances were not correct. This has now been fixed. |
TSAC-4399 | Steel components | Joist to column, type 1 (161): Previously, defining the cut back distance of the bottom chord caused the component to crash. This has now been fixed. |
TSAC-4453 | Steel components | Base plate (1004), Web stiffened base plate (1016): Previously, the leveling plate did not follow the position of the additional beam. This has now been fixed. |
TSAC-4491 | Steel components | Seat type 9 (73): Previously, setting the number of bolts to 0 for the vertical or horizontal direction caused Tekla Structures to crash. This has now been fixed. |
TSAC-4501 | Steel components | Haunch (40): Previously, when two-sided haunches were created, some welds were missing for the second haunch. This has now been fixed, and all welds are created correctly. |
TSAC-4572 | Steel components | Gusseted cross (62): Previously, slotted holes for clip angles for the second brace were applied incorrectly in the component. This has now been fixed. |
TSAC-970 | Steel components | Railings (S77): The start and end closures are now fitted to the first and last stanchion. |
TSAC-4380 | Import, export, interoperability | Export Unitechnik (79): Previously, the Tekla Structures version option for the File creator (UT 6.0) setting was not working correctly. This has now been fixed. |
TTSD-34846 | Import, export, interoperability | Sometimes inserting a reference model failed because of special characters. Now all characters below 256 are allowed in a reference model file name: both ASCII (0-127) and extended ASCII (128-255). |
TTSD-36914 | Import, export, interoperability | IFC2x3 export: The Tapered curved rebar groups are no longer exported so that the self-intersecting bars are clashing (2D). |
TTSD-37037 | Import, export, interoperability | Trimble Connector no longer consumes a Trimble Connect Business Premium license. Previously, a Trimble Connect Business Premium license was consumed, even though using Trimble Connector does not require this type of a licence. This prevented the use of the same license seat in Trimble Connect, so the user could not access the Trimble Connect features that were available for Business Premium users. |
TTSD-37406 | Import, export, interoperability | You can now convert IFC objects in ELITECAD models to Tekla Structures native objects. |
TTSD-37466 | Import, export, interoperability | IFC2x3 export: Welds are now exported with solid colors. |
TPLED-165 | Templates and reports | Template library now gives more descriptive conversion warning messages that show the component name and template filename. |
TPLED-173 | Templates and reports | Template Editor: Previously, when the row sort type of a template was set to None, the row order could sometimes change. This has now been fixed. |
TPLED-178 | Templates and reports | Previously, column headers were not positioned correctly in tables that were filled vertically from top to bottom and aligned to the right. This has now been fixed. |
TTSD-37364 | Templates and reports | The LOCKED_BY drawing attribute now returns the correct value. |
TTSD-20200 | Drawings | Previously, when you printed drawings to plot files, when a revision was included in a plot file name that contained a period (for example, a date), the revision text was not inserted in the correct location. This has now been fixed. |
TTSD-20331 | Drawings | Printing: Previously, the PaperSizesForDrawings.dat file was not always read from the correct folder. This has now been fixed. |
TTSD-32458 | Drawings | Previously, Tekla Structures could sometimes crash when you moved several drawing views at one go from one drawing to another drawing. This has now been fixed. |
TTSD-33468 | Drawings | Symbol files in the model were not used in printing if the same symbol file was present elsewhere (defined by DXK_SYMBOLPATH). This has now been fixed. |
TTSD-37352 | Drawings | Lines that link rebar dimensions are now drawn using drawing coordinates instead of model coordinates. This means that reinforcement marks are placed correctly again. |
TTSD-39027 | Drawings | Sometimes Tekla Structures froze when you opened a drawing that contained graphical objects (polygons) with hatches. This has now been fixed. |
TTSD-39216 | Drawings | Creating a polyline or a polygon in drawings no longer causes a Tekla Structures application error. |
TTSD-30917 | Tekla Model Sharing | If the value of XS_COLLECT_MODEL_HISTORY is FALSE when you start sharing a model, the Start sharing command will change the value to TRUE automatically. However, previously the Sharing history dialog box did not show the sharing history, even though the value had been changed to TRUE. This has now been fixed. |
TTSD-37935 | Tekla Model Sharing | Previously, start sharing and write out could sometimes fail if the temporary packet creation file was locked by another application, a virus scanner, for example. This has now been fixed. |
TTSD-37993 | Tekla Model Sharing | Previously, excluding a folder from sharing only worked for folders directly under the model folder, not for sub-folders. This has now been fixed. |
TTSD-38820 | Tekla Model Sharing | Previously, when inviting users to a shared model in the Start sharing dialog box, the email addresses that had capital letters were temporarily shown as duplicated in the list of users until you reopened the dialog box. There were also issues in receiving email invitations to the model. Now this has been fixed. |
TTSD-39160 | Tekla Model Sharing | Previously, downloads were occasionally jammed in the Tekla Model Sharing service when reading in or joining a model. This was most likely related to limited internet bandwidth when several packets were read in or when joining a large model. The issue has now been fixed in this service pack. If you are a Tekla Model Sharing on-premises server user, note that this Tekla Structures service pack is not compatible with on-premises server versions older than version 3.13.9. To continue using Tekla Model Sharing, you need to update the Tekla Model Sharing on-premises server to version 3.13.9. Tekla Model Sharing on-premises server version 3.13.9 is downward compatible. All previous Tekla Structures versions in which Tekla Model Sharing is available, starting from Tekla Structures 21.0, work with this server version. |
TTSD-33685 | Modeling | Previously, in some rare cases, Tekla Structures could crash when you moved a custom component and then modified a property in the custom component dialog box. This happened when a bent plate was used in the custom component that was located far away from the origin. This has now been fixed. |
TTSD-35585 | Modeling | Sometimes, if pours were enabled in a model (XS_ENABLE_POUR_MANAGEMENT was set to TRUE ), broken solids caused Tekla Structures to crash when opening the model. This has now been fixed so that Tekla Structures does not crash anymore. |
TTSD-37392 | Modeling | You can now import .lis catalog profiles with a numeric SUB_TYPE value. |
TTSD-37491 | Modeling | In the Snapping toolbar, the list for selecting the snap depth (Auto/view plane) now works correctly. |
TTSD-38386 | Modeling | When merging complex parts by using the Added material > Attach to part command, Tekla Structures sometimes crashed. This has now been fixed. |
TTSD-25375 | Licensing | Administrators can now set a registry setting so that the license expiry messages will not be seen by users. This can help in situations where overnight processing is run using Tekla Structures - the overnight processing is not impacted when licenses have less than 1 month until the expiry. |
TTSD-31795 | Installation | Previously, .tsep system logging sometimes conflicted with virus scanners, which could cause issues in extension or environment installations. The .tsep logging has now been changed to make it more robust, and to allow scanning of the log while in use. |
TTSD-33042 | Installation | Model environment information is now taken from XS_SYSTEM . The folder under \Environments\ is used as the environment name. |
TTSD-37957 | Installation | When importing .tsep files with Tekla Structures extension manager, Tekla Structures shows a message that asks whether you want to delete or keep the original .tsep files. This message has now been improved. The Yes and No buttons have been renamed as Delete and Keep to help you in selecting the appropriate action. |
TTSD-34876 | Tools and components | Symbol Editor: Previously, saving with Save As did not work if the edited symbol file was located in the model folder. This has now been fixed. |
TTSD-35938 | Tools and components | Previously, you could not open the dialog box of a .NET component published in the Applications & components catalog. This has now been fixed. .NET components now correctly use their attribute file when inserting the components to the model. |
TTSD-24536 | Numbering | Previously, when numbering the model, clicking Cancel in the numbering report could reset any custom setting in some dialog boxes opened from the ribbon, for example, in dialog boxes under Numbering settings and Drawing properties. This has now been fixed. |
TTSD-38656 | User interface | The height of the monitor or the number of monitors do not cause issues anymore with the saved Windows registry values for the Width of the snapping toolbar. |
TTSD-22567 | User interface | In the Applications & components catalog, the search box tooltip text has been improved. The square brackets are now shown correctly as [ ], instead of a rectangle []. |
TTSD-27811 | User interface | Clicking the Image
|
TTSD-37485 | User interface | When using DirectX rendering, software rendering is no longer forced in remote desktop connections. You can still use the XS_USE_SOFTWARE_RENDERING advanced option, if needed. |
TSAC-4316 | Import, export, interoperability (concrete) | EliPLAN export (68): You can now use user-defined template properties with the Weight calculation option Template. |
TSAC-4342, TSAC-4367 | Import, export, interoperability (concrete) | Export Unitechnik (79): The following options have been added on the Reinforcement tab:
|
TSAC-4432 | Import, export, interoperability (concrete) | Export Unitechnik (79): You can now specify a manual Unitechnik mesh type using an UDA option for Mesh type on the Unitechnik tab in the reinforcement user-defined attributes dialog box. If you leave the option blank, automatic mesh type is used like before. |
TSAC-4489 | Import, export, interoperability (concrete) | Export Unitechnik (79): Previously, the exposure class for both shells of a double wall was read from the first shell. This has been fixed, and the exposure class is now read from each of the shells. |
TSAC-4509 | Import, export, interoperability (concrete) | Export Unitechnik (79): Previously, for double walls with a shell offset at start end, and 1st shell turning enabled in the Double wall turned setting on the TS configuration tab, the second shell of the double wall had an incorrect X axis offset. This has now been fixed. |
TSAC-4526 | Import, export, interoperability (concrete) | BVBS Export: On the Data content tab, in the Position source setting, there is a new option Reinforcement template available. |