The engineer shall verify that the properties of the selected grades are those that are characteristic of the material, are obtained from up-to-date manufacturer’s data and are applicable to the analysis model. Analysis Modification Factors must also be confirmed to be correct.

Head Code Eurocode

The following assumptions have been made:

  • Loading will be perpendicular to the wide faces of the laminations (bending about the major axis).

  • Moisture content of the sections will be less than 15% - analysis modification factors may need to be applied if this is not the case.
  • The glulam grade being used complies with the characteristic properties outlined in BS EN 14080:2013.
  • The engineer has verified that the Eanalysis value of the member is suitable for the particular application.
  • The section and strength class are compatible.

Head Code ACI/AISC

The following assumptions have been made:

  • The moisture content of the structural composite lumber or glulam section is less than 16% and the temperature remains below 100°F - analysis modification factors may need to be applied if this is not the case.

  • The glulam section will be loaded perpendicular to the wide faces of the laminations (bending about the x-x axis).
  • The glulam grade being used complies with the characteristic properties outlined in AWC NDS supplement 2018.
  • The engineer has verified that the Eanalysis value of the member is suitable for the particular application.
  • The section and strength class are compatible.