Tekla Structures 2025 수정 사항 목록

Tekla Structures
수정됨: 12 2월 2025
2025
Tekla Structures

Tekla Structures 2025 수정 사항 목록

Tekla Structures 2025는 Tekla Structures 2024 서비스 팩 SP7까지 릴리스된 모든 수정 사항을 포함합니다. 이러한 수정 사항은 Tekla Structures 2025 수정 사항 목록에 포함되지 않습니다.

수정

결함 번호 개발 영역 설명
TSAC-7696 Concrete components

Automatic splicing tool: Names and numbering settings are no longer missing from the split reinforcing bars.

TSAC-8820 Concrete components

Concrete stairs (65): Previously, stairs were created with the wrong height when the rounding edge of steps was set to zero on the Step shapes tab.

TSAC-8901 Concrete components

Rebar coupler: Previously, the Rebar coupler component was in some situations creating separate, short end detail modifiers for each rebar. This issue has now been fixed and only one modifier is created on both sides of the splitter.

TSAC-9054 Concrete components

Reinforced concrete stairs (95): Previously, when the bottom anchor bars were split to avoid holes in landings, the part closer to the edge of the landing was retained and the part closer to the inside of the stairs was removed. This issue has now been fixed so that the part closer to the edge is removed and the part closer to the inside is retained.

TSAC-6569 Steel components

Metsec Std anti-sag bay (23): The Metsec standard anti-sag component now has the option to add diagonal tie wires as part of the system.

TSAC-6635 Steel components

Column splice (132): Previously, weld default sizes were set to zero. This issue has now been fixed.

TSAC-7869 Steel components

Two sided clip angle (143): Clip angles are now better fitted when bolts are staggered and safety connections are used.

TSAC-8109 Steel components

Seating (39): Previously, when a contour plate was used as the secondary part, incorrect notches were created. This issue has now been fixed.

TSAC-8193 Steel components


Stiffened end plate (1014): Previously, weld 4 was created on opposite sides of the stiffener plates. This issue has now been fixed.
 

TSAC-8252 Steel components

End plate (144): It is now possible to use weld 8 as the weld between the haunch plate and the end plate.
 

TSAC-8560 Steel components

Stairs (S71), Wooden stairs pan (S72), Polybeam pan (S73), Z pan (S74): Previously, upper and lower vertical and horizontal plates were getting new GUIDs in every modification of the component. This issue has now been fixed.

TSAC-8954 Steel components

Fitting (13): Previously, square notch cuts were created with incorrect materials. This issue has now been fixed.

TSAC-8956 Steel components

End plate (29): Previously, the bolt standard of galvanizing holes was applied as the finish property for stiffeners. This issue has now been fixed.
 

TSAC-8957 Steel components

End plate (101): Previously, square notch cuts were created with incorrect materials. This issue has now been fixed.

TTSD-63307 Import, export, interoperability

IFC2x3 export: The export of polybeams with asymmetric profiles produced rotated profile segments in some cases. This issue has now been fixed.

TTSD-63838 Import, export, interoperability

Reference models: Tekla Structures stopped responding when you were inserting a DWG reference model if the reference model had a percent sign "%" in the file path. This issue has now been fixed.

TPLED-334 Templates and reports

Template Editor: Previously, in a row rule, CopyField() did not use the final output value, but used an intermediate value. This issue has now been fixed.

TTSD-66659 Templates and reports

The DRAWING.CHANGES attribute can now be used in representation filtering to highlight changed drawings in a model.

TSAC-8440 Drawings

Hole dimensions: The associativity of the dimensions on round holes now works correctly.

TSAC-8506 Drawings

A critical error occurred when you used the Undo command after the Combine lines command. This issue has now been fixed.

TSAC-8546 Drawings

View-specific dimensioning: In rule based dimensioning, when the Close lines setting was off and only one object was dimensioned, the Place dimensions inside setting did not work, but the dimension was placed outside. This issue has now been fixed.

TSAC-8777 Drawings

Rebar mesh view creator: The Rebar mesh view creator now creates a view filter to avoid the inclusion of any bar that does not belong to the current cast unit.

TTSD-39258 Drawings

Master drawing catalog: Master drawing catalog can now read object filters and rule wizards from the subfolders under the XS_FIRM and XS_PROJECT folders.

TTSD-50067 Drawings

Showing neighbor parts: Previously, turning the neighbor parts visible in the neighbor part properties did not work unless some view property, for example, View extension for neighbor parts was also modified. This issue has now been fixed.

TTSD-52214 Drawings

Dimensioning: Earlier, when you copied a dimension that had associativity rules different from the default, the copied dimension points were not associative. This issue has now been fixed.

TTSD-54604 Drawings

Level marks: Level mark frame is now drawn on top of the text, and the leader line is no longer hidden by the background mask.

TTSD-55279 Drawings

Radial grids: Radial grid curvature is now visualized better in drawings, resulting in better output in printing.

TTSD-55733 Drawings

Surface treatment in drawings: Invisible surface treatment in drawings is now handled faster, which makes drawing opening and update faster. 

TTSD-55788 Drawings

Clone selected: The Clone selected feature did not always work correctly when the drawing was zoomed out. This issue has now been fixed.

TTSD-56122 Drawings

When using save-numbering-save, drawing is not opened until you close the save-numbering-save dialog either by canceling or saving.

TTSD-57724 Drawings

Previously, selecting parts by the selected multi assembly drawing selected all parts shown in the drawing. Now, similarly to earlier Tekla Structures versions, only parts or assemblies with positions used to create the multi assembly drawing are selected.

TTSD-59190 Drawings

It was not possible to select the parts that had overlapping lines removed if you had set XS_ENABLE_OVERLAPPING_CUT_LINE_REMOVAL to TRUE. This issue has now been fixed.

TTSD-60380 Drawings

Hatches in drawings: Dots in the hatch pattern definition are now interpreted as dots. Earlier, dots were not interpreted correctly.

TTSD-60455 Drawings

There is a custom line type CONTINUOUS in addition to the default continuous line type in drawings.
The advanced option XS_ENABLE_OVERLAPPING_CUT_LINE_REMOVAL now treats CONTINUOUS line type as continuous just like the default continuous line type.

TTSD-60750 Drawings

Document manager: Now Document manager also allows changing the drawing version with the following license types: Carbon, Viewer, and Production planner.

TTSD-61167 Drawings

Section views: Section views that are moved to another drawing now adapt better to changes in the model.

TTSD-62128 Drawings

Layout editor: Sometimes a drawing size may have shared tables and their positions with another size. This issue has now been fixed for old and new layouts.

TTSD-62276 Drawings

The CONTINUOUS line type is now treated as a solid line type in overlapping cut line removal.

TTSD-62776 Drawings

Printing: Printing no longer stretches the print preview.

TTSD-63208 Drawings

DWG files in drawings: Tekla Structures is now able to show the DWGs inserted in drawings with better quality.

TTSD-63702 Drawings

The All files option is now available in the Rich text drawing property pane in the file browser when you are adding a rich text file in a drawing.

TTSD-64335 Drawings

In drawings, hidden lines of concrete parts are now fully visible through solid fills. Previously, when the fill hatch was solid, the underlaying hidden lines where not shown.

TTSD-64389 Drawings

Drawing content manager: The number of weld marks is now reported correctly in the Mark qty column.

TTSD-64468 Drawings

Some drawing creation scenarios did not trigger autosaving in accordance with the defined Autosave after creating every nn drawings autosave option. This issue has now been fixed.

TTSD-64691 Drawings

Dimensioning: Dimension groups are now correctly checked for associativity.

TTSD-64843 Drawings

Tekla Structures stopped responding when you tried to view a snapshot of a drawing that had no snapshot file. This issue has now been fixed.

TTSD-65234 Drawings

Merging rebar marks: The setting One leader line per row for merged rebar marks did not work correctly. This issue has now been fixed.

TTSD-65374 Drawings

The cross for secondary parts is now always visible if center lines are visible for secondary parts.

TTSD-65582 Drawings

Layout editor: An unnecessary log entry about deleted drawings no longer appears in the drawing log when editing drawing layouts.

TTSD-65705 Drawings

Rebar marks: The NUMBER_VISIBLE attribute sometimes gave an incorrect value in rebar marks. This issue has now been fixed.

TTSD-65795 Drawings

In drawing versions, it was not possible to restore a rebar assembly drawing using Open as new. Now, rebar assembly drawings can be restored in drawing versions.

TTSD-67091 Drawings

Mark template date: When adding a template in a drawing mark, the template date was sometimes incorrect in the Mark content - template dialog. This issue has now been fixed.

TTSD-67224 Drawings

Weld marks: Earlier, in some rare cases, it was not possible to create weld marks for around welds in drawings. This issue has now been fixed.

TTSD-67338 Drawings

Mark elements in drawing view properties: The list of available mark elements in the Marks section in the drawing View properties dialog sometimes had duplicate elements. This issue has now been fixed.

TTSD-67449 Drawings

View-based dimensioning: Earlier, when removing dimensioning points from a dimension created using the view-based dimensioning, the dimensioning tag might show extra objects. This issue has now been fixed.

TTSD-67773 Drawings

Copying dimensions: Now when you copy dimensions, user-defined associativity rules are also copied if possible, otherwise the default rule will be applied.

TTSD-67967 Drawings

DWG/DXF files linked in drawings: The linked DWG/DXF files now have proper color indexes in drawings, and the colors are recognized in printing, for example.

TTSD-60610 Tekla Model Sharing

Tekla Model Sharing: The region codepage check has been improved. Previously, the UTF-8 codepage setting was not recognized when you were joining a model. This has now been fixed, and now UTF-8 is recognized for user region codepage.

Starting to share a model using UTF-8 is now prevented.

TSAC-7824 Reinforcement

Rebar coupler: For vertical bars in a curved wall, the Rebar coupler component created short, individual end detail modifiers for each bar, which caused the rebar set bars to be grouped into one-bar groups. This issue has now been fixed so that a single end detail modifier is created and the bars are grouped correctly.

TTSD-58545 Reinforcement

Rebar sets: An issue was fixed where rebar set bars still got concrete cover information from a part after it was changed to a non-concrete material.

TTSD-60494 Reinforcement

Rebar sets: The adaptivity of rebar set leg faces to part modifications has been improved. When a leg face has equal overlap with more than one part face, the leg face follows the part with the smallest face.

TTSD-61943 Reinforcement

Rebar meshes: The outdated and redundant attributes CC_PITCHING_CROSS and CC_PITCHING_LONG have been removed from the contentattributes_global.lst file. Use CC_CROSS and CC_LONG instead.

TTSD-63166 Reinforcement

Previously, when selecting handles of reinforcement objects using area selection, the number of the selected handles shown on the status bar was sometimes incorrect. This issue has now been fixed.

TTSD-63391 Reinforcement

Rebar sets: Previously, when adding rebar set guidelines, the preview line after adding the first point of the guideline was shown only when the mouse pointer snapped to an object. Now, the preview line is always shown.

TTSD-63415 Reinforcement

Rebar sets: An issue has been fixed with the calculation of bars in a rebar set containing three guidelines. This issue might result in incorrect length or invalid bars, particularly with leg faces at small angle to one another.

TTSD-63931 Reinforcement

Rebar groups: An issue was fixed where a tapered reinforcing bar group had incorrect bar spacings. The bar spacing properties should be applied perpendicular to the bars, but in this case the spacings were applied relative to the tapered bar ends.

TTSD-66565 Reinforcement

Rebar sets: Selection switches now work similarly for rebar set modifiers whether direct modification is on or off. Direct modification for modifiers created by components is only available if the Select objects in components switch is active.

TTSD-67044 Reinforcement

Rebar sets: Rebar set splitters are no longer projected to leg faces when the multi-point picking mode is active. This makes it possible to snap directly to bars, like with other rebar set modifiers.

TTSD-67785 Reinforcement

Rebar shape manager: The definition of the rebar bending shape code 22 has been updated in the RebarShapeRules.xml file in the UK environment.

TTSD-68172 Reinforcement

Rebar sets: An issue was fixed related to the Set as primary button on the contextual toolbar for rebar set guidelines. The button is now only visible for the first or last secondary guideline in rebar sets that have more than three guidelines, and for all secondary guidelines in three-guideline rebar sets.

TTSD-50539 Modeling

Filtering: Previously, the Multi-select from model option in the Value column in the selection filter dialog did not work with some values, for example, with "1" and "10", because both included the same number "1". Now, the Multi-select from model option works with any values even if the values include the same character.

TTSD-61111 Modeling

Highlighting the matches of the Quick Launch search are now shown in semi-transparent yellow color to make them easier to find.

TTSD-62159 Modeling

In Batch editor, the Validation column is now refreshed more reliably when you have manually added new target assemblies.

TTSD-62567 Modeling

Direct modification: Previously, the direct modification controls and/or graphics disappeared in the 3D view when you redrew the view. This has now been fixed.

TTSD-62783 Modeling

Now, when you hover over the coordinate symbol in the lower right corner of the model view, the coordinate symbol displays a hover over effect similar to the one in Trimble Connect.

TTSD-63824 Modeling

Previously, when you deleted a Building hierarchy element, the deletion was not shown in the Undo history list. This issue has now been fixed.

TTSD-65467 Modeling

The model template Sample Office Building has been removed from the Default environment in Tekla Structures 2025.

TTSD-65792 Modeling

Direct modification: Now the dragging works correctly even if you drag a dimension line or a dimension arrow.

TTSD-67565 Modeling

Assemblies and rebar assemblies: After using the Add as sub-assembly or Add to assembly command from the context menu, the message "The part, rebar or assembly was added to the selected assembly" is now displayed on the status bar.

TTSD-67617 Modeling

In Trimble Connector, on the Overlay models tab, only the latest version of each model was shown. This has now been fixed, and the list of versions is fetched when a model is selected. 

TTSD-68253 Modeling

Previously, in the DirectX rendering, hidden objects were incorrectly displayed as shadows. This has now been fixed, and hidden objects remain hidden.

TTSD-68431 Modeling

Previously, welds created with the commands Create polygon weld and Create weld to part were sometimes placed in the model origin. This issue has now been fixed.

TTSD-68519 Modeling

Previously, failures in loading extensions could prevent other functionality in Tekla Structures. Now the failures in extensions are more isolated.

SOLD-2579 Licensing

In some cases where the computer went to sleep while a model was open in Tekla Structures and the computer was offline when the user started it again, the Tekla Structures toolbar was dimmed and work could not continue even after reconnecting to the network. This has now been fixed.

TTSD-64446 Licensing

The message that is shown when a user goes offline has been improved to be more descriptive. To avoid interrupting the user's work, the message is no longer shown as a pop-up.

TTSD-63762 Installation

TSEP now supports version numbers that are compliant with semantic versioning 2.0. For example, 1.2.3, 2.3.5-alpha001.

TTSD-64689 Tools and components

Previously, when a custom component main or secondary part was welded to a component part, the existing assemblies exploded if that main part of secondary part was the main part of an assembly. This has now been fixed.

TSAC-8333 Numbering

Design group numbering: The selection filters in the Group filter lists are now displayed in alphabetical order.

TSAC-8442 Numbering

Design group numbering:

  • You can now use the Compare UDA options to define whether to compare the user-defined attributes of parts.
  • You can click the new Open Multi report generator button at the bottom of the dialog box to create reports using Multi report generator.
TTSD-64522 Numbering

Numbering was slow when %TPL:PHASE% was included in XS_ASSEMBLY_POSITION_NUMBER_FORMAT_STRING or XS_PART_POSITION_NUMBER_FORMAT_STRING. This issue has now been fixed.

TSAC-8056 Import, export, interoperability (steel)

DSTV to DXF converter: The converter now creates all contour markings correctly when any option is selected from the Side to convert list.

TSAC-8382 Import, export, interoperability (concrete)

Export Unitechnik (79): Previously, the automatic calculation of the spacer type did not work correctly in some cases. This issue has now been fixed.

TSAC-8621 Import, export, interoperability (concrete)

Export Unitechnik (79): Previously, when a special formwork attribute code was used, some of the line attributes for openings were not exported correctly. This issue has now been fixed.

TSAC-8813 Import, export, interoperability (concrete)

Export ELiPLAN file (68): Previously, when multiple attributes were specified for the Plot additional reinforcement option, it was not working correctly. This issue has now been fixed.

TTSD-42950 Common

Tekla Structures no longer creates unnecessary log files outside the normal working folders.

도움이 되었습니까?