Tekla Tedds Engineering Library (July 2021)
UK and Asia
Windpost design (EN1993)
New calculation which checks the design of a vertical steel beam acting as a windpost providing lateral support to a masonry wall subjected to a uniformly distributed wind load. Checks the capacity of the wall ties to distribute the wind loads from the loaded leaf to the other leaf. In accordance with EN1993 & EN1996 and the national annex for the UK, Ireland, Singapore, Malaysia, Finland, Sweden, Norway or the recommended Eurocode values.
Other updates
RC corbel design (EN1992)
[TEDDS-5803]1 - Enhanced to include C32/40 concrete grade
[TEDDS-5804]1 - Enhanced to removed limits on the number of legs per link
[TEDDS-5786]1 - Typos in the reinforcement dialog corrected.
RC pile cap design (EN1992/EN1997)
[TEDDS-5737]1 - Fixed preview results error re column punching shear check.
[TEDDS-5726]1 - Fixed pile arrangement validation in the interface not taking into account the pile location tolerance and the pile equivalent length.
Rolling load analysis
[TEDDS-5767]1 - Fixed Area of section reverting to the default value when defining a custom section due to previous fix [TEDDS-3965]1.
Timber connection design (EN1995)
[TEDDS-5445]1 - Correct spurious spacing check fail message associated with a single row of fixings.
[TEDDS-5798]1 - Correct expression error if output options dialog isn't accessed before finishing the UI.
USA
Europe
New calculation which checks the design of a vertical steel beam acting as a windpost providing lateral support to a masonry wall subjected to a uniformly distributed wind load. Checks the capacity of the wall ties to distribute the wind loads from the loaded leaf to the other leaf. In accordance with EN1993 & EN1996 and the national annex for the UK, Ireland, Singapore, Malaysia, Finland, Sweden, Norway or the recommended Eurocode values.
Other updates
RC corbel design (EN1992)
[TEDDS-5803]1 - Enhanced to include C32/40 concrete grade
[TEDDS-5804]1 - Enhanced to removed limits on the number of legs per link
[TEDDS-5786]1 - Typos in the reinforcement dialog corrected.
RC pile cap design (EN1992/EN1997)
[TEDDS-5737]1 - Fixed preview results error re column punching shear check.
[TEDDS-5726]1 - Fixed pile arrangement validation in the interface not taking into account the pile location tolerance and the pile equivalent length.
Rolling load analysis
[TEDDS-5767]1 - Fixed Area of section reverting to the default value when defining a custom section due to previous fix [TEDDS-3965]1.
Timber connection design (EN1995)
[TEDDS-5445]1 - Correct spurious spacing check fail message associated with a single row of fixings.
[TEDDS-5798]1 - Correct expression error if output options dialog isn't accessed before finishing the UI.
Australia
Canada
Footnotes
1 This number is an internal reference number and can be quoted to your local Support Department should further information on an item be required.
Back to top