Engineering library update - July 2022
Tekla Tedds engineering library update (July 2022 - version 24.04) is available in Tekla Downloads.
American Design
Wood member design (NDS)
Enhanced to allow deflection checks to be included when the calculation is used via it's Calc API. When used with Tekla Structural Designer 2022 Service Pack 2 or later the appropriate data for deflection checks will be automatically included when designing timber members from Tekla Structural Designer.
Product bulletin June 2022 (PBT-2206-1)
Wood 2D/member analysis & design (NDS) - Fixed a potentially un-conservative error affecting the calculation of deflection in members affected by either incising, elevated temperatures, or the wet service condition. For more detailed information please refer to Product bulletin June 2022 (PBT-2206-1).
Other Updates
Column base plate design (AISC360) | |
---|---|
TEDDS-6896 | Fixed an undefined variable error when only axial force was specified. |
Wood member design (NDS) Wood member analysis & design (NDS) Wood 2D analysis & design (NDS) |
|
---|---|
TEDDS-6653 | Updated the composite datalist "Composite lumber reference design values-NDS.dls" in accordance with the APA Product Report for RigidLam Feb 2022. |
Australian Design
No updates.
British Design
No updates.
Canadian Design
No updates.
Eurocode Design
Timber member design (EN1995)
Enhanced to allow deflection checks to be included when the calculation is used via it's Calc API. When used with Tekla Structural Designer 2022 Service Pack 2 or later the appropriate data for deflection checks will be automatically included when designing timber members from Tekla Structural Designer.
Other Updates
RC beam design (EN1992) RC 2D analysis & design (EN1992) RC beam analysis & design (EN1992) |
|
---|---|
TEDDS-6912 | Fixed the National Annex defined crack control equation being overwritten by the 'Initialise crack expressions' item. |
Precast concrete stair design (EN1992) RC stair design (EN1992) |
|
---|---|
TEDDS-6613 | Enhanced to remove the minimum number of risers limitation so that stairs with 1-4 risers can be designed. |
TEDDS-6614 | Enhanced to remove the minimum lower landing length limitation so that a value of zero can be used to design stairs with no lower landing. |
RC pile cap design (EN1992/EN1997) | |
---|---|
TEDDS-6803 | Fixed undefined variable '_DRVRdmaxCritID' when designing a triangular pile cap. |
Steel masonry support (EN1993) | |
---|---|
TEDDS-6829 | Fixed validation on Geometry button for plates to underside of beam. |
TEDDS-6932 | Fixed incorrect default load combination when using a national annex that only has one combination for Eqn6.10a/b available. |
Timber frame racking loads (EN1991) | |
---|---|
TEDDS-6895 | Fixed undefined variable error when selecting the Irish NA with a duopitch roof. |