Use the Sub Models properties to view or modify the selected sub model.

Property Description

Override model's

Select this check box in order to override the Structure meshing properties in the current sub model.

Shell Mesh Size

Defines the shell mesh size for two way spanning slabs in the sub model.

Shell Uniformity Factor

Defines the shell mesh uniformity factor for two way spanning slabs in the sub model.

Slab Mesh Type Defines the shell mesh type used in the sub model.

These options are:

  • Quad only
  • Tri only
  • Quad dominant

Semi-Rigid Mesh Size

Defines the semi-rigid mesh size when slabs are modeled as semi-rigid diaphragms in the sub model.

Semi-Rigid Uniformity Factor

Defines the semi-rigid uniformity factor when slabs are modeled as semi-rigid diaphragms in the sub model.

Semi-Rigid Mesh Type

Defines the semi-rigid mesh type when slabs are modeled as semi-rigid diaphragms in the sub model.

The options are:

  • Quad only
  • Tri only
  • Quad dominant