Note: Partial safety factors are only applicable to EC3 and relevant National Annexes.
Setting Description

Partial safety factors

Use user defined partial safety factors

When Use user defined partial safety factors is selected, the options to define partial safety factors are enabled.

Otherwise, the corresponding country defaults will be used.

Note: Default for this setting is unselected.

Resistance of cross-sections, γM0

Specify a user-defined value for this partial safety factor as required.

Resistance of members to instability, γM1

Specify a user-defined value for this partial safety factor as required.

Resistance of cross-sections to tension, γM2(EC3 - Part 1-1)

Specify a user-defined value for this partial safety factor as required.

Resistance of joints, γM2(EC3 - Part 1-8)

Specify a user-defined value for this partial safety factor as required.