TSAC-8176 |
Concrete components |
Embedded anchors (008): Anchors were sometimes attached to a non-existing face of the main part if the part was an union of multiple parts. This issue has now been fixed. |
TSAC-8210 |
Concrete components |
Embedded anchors (008): Previously, reading anchors from a configuration file was available only for custom part type of anchors. Now this is available also for custom detail and connection type of anchors. |
TSAC-8154 |
Steel components |
Corner bolted gusset (57): Previously, welds between the gusset, main part, and last secondary part were not created correctly. This issue has now been fixed. |
TSAC-8155 |
Steel components |
Bolted gusset (11): Previously, weld 1 was created incorrectly in some cases. This issue has now been fixed. |
TSAC-8157 |
Steel components |
Shear plate to tube column (47): Previously, the slot through the main part was not created correctly when the shear tab was sloped. This issue has now been fixed. |
TSAC-8181 |
Steel components |
Stanchion side profile (86): Previously, the Slots in option on the Bolts tab was not working correctly. This issue has now been fixed. |
TSAC-8195 |
Steel components |
Partial stiff end plate (65): Previously, the component did not work correctly with cold rolled profiles. This issue has now been fixed. |
TSAC-8198 |
Steel components |
Welded beam to beam (123): Previously, weld number 10 was created incorrectly in some cases. This issue has now been fixed. |
TSAC-8225 |
Steel components |
Beam to column web connections: Previously, the advanced option XS_STANDARD_STIFFENER_WIDTH_TOLERANCE was used also for partial width stiffeners. This issue has now been fixed. |
TSAC-8244 |
Steel components |
Weld preparation (44): Previously, welds number 2 and 3 were created incorrectly. This issue has now been fixed. |
TSAC-8245 |
Steel components |
Welded beam to beam (123): Previously, weld number 3 was created incorrectly in some cases. This issue has now been fixed. |
TSAC-8282 |
Steel components |
Splice connection (77): Previously, some default values for welding were calculated incorrectly. This issue has now been fixed. |
TSAC-8305 |
Steel components |
Two sided clip angle (143): Previously, when the clip angles were created on the far side and the secondary parts were C or U profiles, some bolts were created incorrectly. This issue has now been fixed. |
TSAC-8369 |
Steel components |
Bent plate (190): Previously, the weld gap option on the Plates tab was not working correctly. This issue has now been fixed. |
TSAC-8381 |
Steel components |
End plate (144): Previously, shim plates were created in incorrect positions in some cases. This issue has now been fixed. |
TSAC-8399 |
Steel components |
Bolted gusset (11): Previously, flange cuts were created with an incorrect thickness. This issue has now been fixed. |
TSAC-8435 |
Steel components |
Stiffened end plate (27): Previously, welds in the component were created as separate one-sided welds, which caused too many weld marks in drawings. This issue has now been fixed. |
TSAC-8448 |
Steel components |
Shear plate simple (35): Previously, the cope radius was incorrectly applied in some cases. This issue has now been fixed. |
TSAC-8457 |
Steel components |
UltraZED Side rail supports (40): The modeling error for the sloping SRS struts has now been corrected. |
TSAC-8486 |
Steel components |
Simple base plate 2 (1031): Previously, the weld between the key profile and the base plate was not created correctly. This issue has now been fixed. |
TSAC-8496 |
Steel components |
Stiffeners (1003): You can now select on the Parameters tab whether the component searches for input parts created as composites of welded parts. |
TTSD-58141 |
Import, export, interoperability |
Some British UB profiles were not mapped correctly when transferring models between Tekla Structural Designer and Tekla Structures, for example, UB406*140*53 and UB610*178*100. This issue has now been corrected. |
TTSD-60649 |
Import, export, interoperability |
Reference models: Non-IFC reference models are now drawn correctly in 3D views after undo or redo. |
TTSD-61294 |
Import, export, interoperability |
Trimble Connector: Previously, folders were not automatically detached when the folder was removed from a Trimble Connect project. This has now been fixed. |
TTSD-61923, TTSD-61931 |
Import, export, interoperability |
IFC4 export: A sub-assembly that is created as IfcDiscreteAccessory or IfcMechanicalFastener is now exported completely. |
TTSD-62589 |
Import, export, interoperability |
Export to Tekla Structural Designer: Exported beams with L profiles are now correctly positioned in Tekla Structural Designer. Previously, the horizontal alignment and the sign of the minor offset were incorrect in Tekla Structural Designer. |
TTSD-62632 |
Import, export, interoperability |
Point clouds: Point clouds sometimes stopped working. This issue has now been fixed. |
TTSD-63326 |
Import, export, interoperability |
IFC4 export: The order of the rows for the originating system and preprocessor version in the IFC4 file header now complies with the requirements in the buildingSMART standards. |
TTSD-63605 |
Import, export, interoperability |
Earlier, users with a Graphite license could not export NC files in DSTV format with the "All parts" option. This issue has now been fixed. |
TTSD-63623 |
Import, export, interoperability |
Point clouds: The field for entering the point cloud URL in the Attach point clouds dialog box now supports both uppercase and lowercase letters. Previously, Tekla Structures converted the URL path to lowercase. |
TTSD-63667, TTSD-62761 |
Import, export, interoperability |
IFC2x3 export: The export of the surface treatment is now supported for the following entities:
IfcBeam
IfcBuildingElementPart
IfcBuildingElementProxy
IfcColumn
IfcDoor
IfcFooting
IfcMember
IfcPile
IfcPlate
IfcRamp
IfcRoof
IfcSlab
IfcStair
IfcWall
IfcWallStandardCase
IfcWindow |
TTSD-62340 |
Templates and reports |
When inquiring rebar sets, the Total weight value of the rebar set could sometimes differ considerably from the Total weight in group value displayed for the same rebar set
- when the rebar set has been exported as an IFC file and examined in Trimble Connect
- when the rebar set is presented in Organizer
Now the Inquire dialog box shows the same total weight as Organizer and Trimble Connect. |
TTSD-62949 |
Templates and reports |
Template Editor: Using a CopyField() function to a value field that has a formula containing the ROW_IN_ALLPAGES attribute returns an incorrect value. This issue has now been fixed.
Now GetValue("ROW_IN_ALLPAGES") also returns the correct number of rows. |
TSAC-7985 |
Drawings |
Drawing 2D library: Proper support for handling dimension sets has been added. |
TSAC-8409 |
Drawings |
Rebar mesh view creator: You can now create mesh views from any view type, not only from front and back views. You can also create mesh views from views in general arrangement drawings. |
TSAC-8458 |
Drawings |
2D Library
The 2D library has been improved in the following ways:
- Issues with the text frame in marks that have black background haven been fixed.
- The scaling of marks, dimensions, text, and symbols is now working.
- Images are now supported.
- Rich text is now supported.
- Issues with the text leader line have been fixed.
- The text scale inside rich text boxes is now working.
|
TSAC-8482 |
Drawings |
Relabeling section and detail views: When you were relabeling section or detail views using the relabeling tool, the tool stopped working in some rare cases. This issue has now been fixed. |
TTSD-57507-2023SP10 |
Drawings |
Clone selected: Previously, when a mark had a template as the content, the template values did not change when you cloned the marks to new objects, and you had to update the marks manually. Now the values are updated automatically.
This fix was already released in Tekla Structures 2023 SP6, but the problem was not fixed completely. |
TTSD-58126 |
Drawings |
Earlier, if the geometry of the last section of the polybeam was defined by arc by three points chamfer, the bending line was not shown in the correct location in the drawing. This issue has now been fixed. |
TTSD-58841 |
Drawings |
Earlier, when selecting parts for the multidrawing selected in Document manager, the bolted parts could be selected too, even if some of the parts were not shown in the drawing. This issue has now been fixed. |
TTSD-59065 |
Drawings |
Drawing view labels: Previously, the text position of drawing view labels sometimes changed when you modified the section view name. This was due to conflicting Text position properties between the Section mark with view and Drawing view objects. Now, if you modify the Drawing view object after the section mark creation, changes made to the Section mark with view object no longer override the properties of the drawing view. |
TTSD-60743 |
Drawings |
Drawing hatches: Custom hatches from hatch_types2.pat file were not available for selection in the drawing property pane. This issue has now been fixed. |
TTSD-62425 |
Drawings |
Drawing weld marks: Drawing weld marks showed first decimal places when the welding angle was exactly 15, 30, 60, or 120 degrees. For example, 15.0 was shown instead of 15. This issue has now been fixed and decimals are shown only when needed. |
TTSD-63223 |
Drawings |
Weld marks: Earlier, when you deleted a weld from the model and opened a drawing that contained an automatic model weld mark for the deleted weld, the automatic model weld mark changed into a drawing weld mark. This issue has now been fixed. |
TTSD-63843 |
Drawings |
Fabrication drawings: The Applied settings list in the Creation review dialog box might sometimes show the same drawing settings file more than once. This issue has now been fixed. |
TTSD-63953 |
Drawings |
Fabrication drawings: Creating fabrication drawings from corrupted assemblies sometimes caused a Tekla Structures application error. This issue has now been fixed. |
TTSD-63985 |
Drawings |
Earlier, if a drawing view property file used dimension property files that had the "#" character in the names, saving the view property file through the property pane cleared the dimensioning rules. This issue has now been fixed. |
TTSD-62366 |
Tekla Model Sharing |
Tekla Model Sharing: Previously, autosave could cause the model database/autosaved database to end up in an incorrect state. Now, autosave is stopped during model sharing operations, such as write out. |
TTSD-63193 |
Tekla Model Sharing |
Tekla Model Sharing: Previously, when you wrote out, the error message for a locked file did not contain the correct reason. This has now been fixed. |
TTSD-58568 |
Reinforcement |
Rebar sets: Previously, when creating rebar sets using the Point input command, it was not possible to use the Enter a Numeric Location dialog box and type the location of the first point in the rebar set. The subsequent points of the rebar set could be typed. This issue has now been fixed. |
TTSD-62850 |
Reinforcement |
Rebar sets: A potential problem with handling of relations between rebar sets during model opening, which could cause incorrect layering, has now been fixed. |
TTSD-63082 |
Reinforcement |
Rebar sets: An issue has been fixed with the calculation of bars in a rebar set containing three guidelines which may result in incorrect length or invalid bars. |
TTSD-63728 |
Reinforcement |
Rebar sets: An issue has been fixed whereby rebar set layer numbers and offset were not calculated correctly in some cases when two rebar sets were changed from overlapping to not overlapping. |
TTSD-59258 |
Modeling |
Clash check manager: Rebar set and rebar group object names were not displayed correctly in clash check results. This issue has now been fixed. |
TTSD-62720 |
Modeling |
Assembly ID has been removed from the columns that are available in the Clash check manager dialog box. The Assembly ID column is not available due to performance reasons, as fetching assembly information makes displaying clash check results slow. Assembly ID is shown in the detailed clash check results. |
TTSD-63295 |
Modeling |
Now, when the direct modification is on, the selecting of contour plates and slabs with details has been optimized. |
TTSD-63863 |
Modeling |
Now, when you copy properties in the property pane, the property pane does not reset the possible manual modifications that you have done. |
SOLD-2405 |
Licensing |
It was not possible to use Tekla Structures 2023 SP5 and newer versions and 2024 at the same time as Tekla Structures 2021 and older, Tekla Structures 2023 SP4 and lower, or 2022 SP10 and lower. This issue has now been fixed for Tekla Structures 2023. Changes have also been made to improve how Tekla Structures 2023 handles Windows updates. |
TTSD-63746 |
Licensing |
Earlier, when you used floating licenses for Tekla Model Sharing, a license seat was reserved when you opened a shared model. Now, the license seat is only reserved when you start a Tekla Model Sharing operation, such as read in or write out. |
TTSD-63606 |
Installation |
The TSEP package installer no longer warns about unsigned TSEP packages due to signing technology that will be deprecated next year. This change also enables the creation and installation of TSEP installers from cloud services, and the use of new signing technologies in the future. |
TTSD-59556 |
User interface |
When a rebar set is selected, a contextual tab is displayed on the ribbon. Now the all the content on the tab is always visible and there is no scrollbar anymore. |
TTSD-62879 |
User interface |
Property pane: Copying properties to the clipboard now causes less visual blinking than previously. |
TTSD-63359 |
User interface |
Previously, after switching to a different screen setup, sometimes Tekla Structures main window was not visible and there was no means to have it on the visible screen area. This has now been fixed, and Tekla Structures checks the stored window position and size, and ignores them if they are outside the visible screen area. |
TSAC-8574 |
Import, export, interoperability (steel) |
DSTV to DXF converter: The converter now creates all contour marking properly, despite of the selected Side to convert option. |
TSAC-8498 |
Import, export, interoperability (concrete) |
Export Unitechnik (79): Previously, some reinforcement was exported to an incorrect position when you had selected Fabrication of welded rebars as the Reinforcement export type on the Reinforcement tab. This issue has now been fixed. |