Tapered T-beam (m178)
System component Tapered T-beam (m178) can be used to create a precast concrete saddle truss beam with T-shaped cross-section.
Back to topObjects created
- Concrete beam
Use for
Image
| Image
| Image
|
Before you start
Ensure that you have two points to pick.
Back to topSelection order
1. Pick the beam start point.
2. Pick the beam end point.
The beam is created automatically when you pick the end point.
Picture tab
Use the "Picture" tab to define the dimensions of the beam.
| Option | Description | |
|---|---|---|
| 1 | Slope of the flange, next 3 units can be used: • mm (distance) • ° (degrees) • % (percentage) | |
| 2 | Height of the flange sides. | |
| 3 | Height of the beam from the bottom to the highest edge. | |
| 4 | Width of the flange from the side to the web. | |
| 5 | Width of the flange taper. | |
| 6 | Distance between the bottom web edge and the flange side plane. | |
| 7 | Thickness of the flange slab. | |
| 8 | Width of the flange. | |
| 9 | Width of the web. | |
Parameters tab
Use the "Parameters" tab to define the beam parameters.
| Option | Description | |||
|---|---|---|---|---|
| Name | Beam name. | |||
| Material | Material grade. | |||
| Class | Beam class number. | |||
| Prefix | Numbering prefix for the cast unit . | |||
| Start number | Start number for the cast unit. | |||
Chamfers tab
Use the "Chamfers" tab to define and create the line-type chamfers on both sides of the beam along the flange edge.
| Option | Description |
|---|---|
| 1 | Distance Y of the edge chamfer. |
| 2 | Distance X of the edge chamfer. |
About tab
In the "About" tab, general information about the extension and the developer can be found.
All rights reserved. No conclusions can be associated to the representation of the pictures in relation to the operating systems under which Tekla Structures runs.
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. To view a copy of this license, visit http://creativecommons.org/licenses/by-nc-nd/4.0/ or send a letter to Creative Commons, 444 Castro Street, Suite 900, Mountain View, California, 94041, USA.