Metsec Horizontal Cladding Support Column (33)
Not version-specific
Tekla Structures
Environment
Not environment-specific
The Metsec Horizontal Cladding Support Column macro can be used to define an arrangement of PJR or HCS sections between the rails at the column position. The macro can also provide the necessary connections between the top rail and an eaves beam.
Before and after
Image
Image
Notes
- Any modification of the selected parts will cause this macro to be updated.
- Most of the data required for this macro is fixed by Metsec and stored in a series of data files supplied with Tekla Structures. Where standard data is not applicable, then certain items can be modified through the Parameters tab of the properties panel, but it is also possible to tailor the data files to individual requirements. This would require assistance from Tekla Structures support.
- All rails must be connected to the columns using the Metsec Cold Rolled Sleeved (102). Unless the Parameters tab > Top Cleat Type > To Column option is selected when applying the macro.
- Only one eaves beam may be selected for inclusion.
- All rails in the bay must share the same sheeting face.
- All rail lengths must be parallel.
- Eaves beam must be parallel to rails and above the last rail.
- The outside of the rails / eaves beams must align.
Selection order example
- Column
- Rails
- Eaves beams (if required)
- Click middle mouse button
Image
See also
Metsec cold rolled - Important informationMetsec Horizontal Cladding Support Column (33) - Parts tab
Metsec Horizontal Cladding Support Column (33) - Parameters tab