Kingspan Cold Rolled Sleeved (28) - Stays tab

Tekla Structures
Not version-specific
Tekla Structures
Environment
Not environment-specific

Use the Stays tab in the Kingspan Cold Rolled Sleeved Properties panel to control how the stays are defined within Tekla Structures.

Image
tekla-structures-ks-28-stays-tab.png

 

OptionDescriptionDefaultOther
Stay to
(Haunch, Rafter)
This determines where the stays should be positioned if the joint is applied above a haunch. If this is set to haunch the stays will be attached to the haunch otherwise they will be positioned to go to the rafter.
WARNING (see images): If the stay is applied to the haunch and the haunch profile is subsequently modified the stays position will not be re-calculated. This can be resolved by modifying the cold rolled sleeved joint using it’s existing parameters.
NOTE: The haunch must be part of the system haunch connection typically using components 40 or 102.
The default is set to Haunch.
Image
tekla-structures-parameters-tab-stay-to-haunch-modify-before.png
Before
Image
tekla-structures-parameters-tab-stay-to-haunch-modify-after.png
After
Stays on
(None, Both, Right, Left)
This allows the user to define whether they want rafter stays or not, and to place them on only one side of the rafter/stanchion if required. You may wish to include both rafter stays at an overhang in order to allow for future extensions. Left and right are specified from the cleat side as shown in image.The default is set to None, rafter stays are turned off.
Image
tekla-structures-parameters-tab-stays-on-02.png
Stay Section
(Default, RNA, RNB)
This specifies which of the two stay sections to use. If set to Default the value will come from the data files.The default is set to Default. 
Stays Horiz DimensionThis sets the position of the stay bolt along the purlin, measured from the centre of the cleat. The default position is included in the data files and may be the same as a hole used for another purpose (e.g. sleeve). However, if a value is entered here, then completely separate bolt will be defined even if it coincides with another hole. 
Stay Plate Horiz Bolt PosThis sets the position of the bolt from the edge of the stay plate or cleat.This value will come from the data files.
Image
tekla-structures-parameters-tab-stay-plate-horiz-bolt-pos.png
Stay Plate Vertical Bolt PosThis sets the position of the bolt from the end of the stay plate or cleat.This value will come from the data files.
Image
tekla-structures-parameters-tab-stay-plate-vert-bolt-pos.png
Stay Plate Chamfer DimensionThis specifies the chamfer that should be applied to the stay plates defined by the joint.The default setting is 0. 
Stay Cleat Bolt diameterWhere the stay is connected to a cleat, this field specifies the diameter for the bolt connecting the cleat to the rafter/column. Where the stay is connected to a plate and welded to a rafter/column, this field is only relevant if several bolt diameters are applicable to any one stay profile – usually the fabricator’s own. This has to be set up in one of the cold rolled data files before running the joint – contact Tekla Structures support for assistance.This value will come from the data files. 