Kingspan Eaves Beam to Stanchion (27) - Parameters tab

Tekla Structures
Not version-specific
Tekla Structures
Environment
Not environment-specific

Use the Parameters tab in the Kingspan Eaves Beam to Stanchion Properties panel to control how the connecting members are defined within Tekla Structures.

Image
tekla-structures-ks-27-parameters-tab.png

 

OptionDescriptionDefaultOther
Eaves Cleat is (Welded, Bolted)This specifies whether the eaves beam cleat should be welded to the stanchion or bolted. If the bolted option is chosen then a plate will be added to the fixing bracket in order to allow a bolted connection to the stanchion. Otherwise the fixing bracket will be welded directly to the stanchion. The default is set to Welded. 
Overhang dim. Gables onlyThis specifies the overhang dimension for a gable end only. The dimension is measured from the centre of the cleat.Where a sleeve is defined the purlin will be cut back to the standard manufacturer's end gap and the sleeve/stub will be positioned to the overhang. Otherwise the purlin will be extended to the overhang point.
Image
tekla-structures-parameters-tab-overhang-dim-gables-only-03.png
Eaves Bolt StandardThis sets the standard for bolts placed to the bottom flange of the eaves beam.The default setting is 8.8XOX. 
Eaves Beam Web Bolt StandardThis sets the standard for bolts placed to the web of the eaves beam. The default setting is 8.8XOX. 
Standard, Bolts to StanchionThis sets the grade for all the bolts going to the stanchion.The default setting is 8.8XOX. 

See also

Kingspan cold rolled - Important information
Kingspan Eaves Beam to Stanchion (27)
Kingspan Eaves Beam to Stanchion (27) - Parts tab
Was this helpful?