Kingspan Eaves Beam to Stanchion (27)
Not version-specific
Tekla Structures
Environment
Not environment-specific
The Kingspan Eaves Beam to Stanchion connection is used to create a bolted or welded connection between the eave beam and column/stanchion. If an overhang is required at the gable this should be done within the joint, not by manually extending the eaves beam at the start and end points. The joint will define all bolts and welds required, and where appropriate will also fit the ends of the eaves beams to leave the correct end gap.
Before and after
Image
Image
Notes
- Any modification of the selected parts will cause this joint to be updated.
- When connection is applied the default connecting profile is always an L100*75*8, this can be overwritten in the Parts tab.
- Eaves beam and front face of the column/stanchion must be parallel.
Selection order example
- Column
- Eaves Beam
- Eaves Beam
- Click middle mouse button
Image
See also
Kingspan cold rolled - Important informationKingspan Eaves Beam to Stanchion (27) - Parts tab
Kingspan Eaves Beam to Stanchion (27) - Parameters tab