CMF Eaves Beam to Stanchion (27) - Parts tab

Tekla Structures
Not version-specific
Tekla Structures
Environment
Not environment-specific

Use the Parts tab in the CMF Eaves Beam to Stanchion Properties panel to control the member properties of the items created by the joint. By default this connection creates a single CMF item, changing any of the default profiles will result in the individual parts being seperate welded items.

Image
tekla-structures-cmf-27-parts-tab.png

 

OptionDescriptionDefaultOther
Connecting ProfileThis specifies a profile to be used for the centre portion of the fixing bracket. The default setting is L100*75*8. 
StiffenerThis specifies the stiffener profile to be used where the standard manufacturer's is not to be used. The default profile will be determined appropriately from the model data. 
PlateThis specifies the profile to be used for the plate where the standard manufacturer's plate is not to be used. The plate, and its associated data is defined in the data files. To override the plate use the t,b,h values featured below.The default plate will be determined appropriately from the model data. 
Plate, tThis sets the thickness of the plate which is connected to the stanchion in the joint if the fixing bracket is bolted.The default setting is 10mm.
Image
tekla-structures-parts-tab-stanchion-plate-t.png
Plate, bThis sets the width of the plate which is connected to the stanchion in the joint if the fixing bracket is bolted.The default setting is 160mm.
Image
tekla-structures-parts-tab-stanchion-plate-b.png
Plate, hThis sets the height of the plate which is connected to the stanchion in the joint if the fixing bracket is bolted.The default height will be determined appropriately from the bolt data.
Image
tekla-structures-parts-tab-stanchion-plate-h.png
Pos_No
(Part position number)
The part position number consists of a prefix and a start number.
1. Prefix
2. Start number
Some connections have a second row for the part position number where you can enter the assembly position number.
The part position number defined in the connection dialog box overrides the settings defined in the components settings in File menu --> Settings --> Options.
Image
tekla-structures-parts-tab-pos-no-02.png
MaterialThis is the material grade that will be used for the fitting bracket created in the joint.The default value for this is taken from File menu --> Settings --> Options --> Components --> Part material. 
NameThe profile name cannot be amended.  

See also

CMF cold rolled - Important information
CMF Eaves Beam to Stanchion (27)
CMF Eaves Beam to Stanchion (27) - Parameters tab
CMF Eaves Beam to Stanchion (27) - Bolts tab