Use the Parts tab in the CMF Cold Rolled Sleeved Properties panel to control the member properties of the items created by the joint.

Image
tekla-structures-cmf-120-parts-tab.png

 

OptionDescriptionDefaultOther
Cleat ProfileThis specifies the profile to be used for the cleat where the standard manufacturer's cleat is not to be used. That cleat, and its associated data is defined in the data files. To specify an alternative cleat you may either enter the name of any profile stored in the profile database or use a parametric profile to create the required profile for the cleat.Standard manufacturer's cleat from the data files. 
Cleat AssemblyThis sets the assembly prefix for the cleat defined in the joint.The default is set to CR. 
SleeveThis specifies the profile to be used for the sleeve where the standard manufacturer's sleeve is not to be used. The sleeve, and its associated data is defined in the data files. Please contact Tekla Structures support if you need to add any extra ones.Standard manufacturer's sleeve from the data files. 
Sleeve AssemblyThis sets the assembly prefix for the sleeve defined in the joint.The default is set to CR. 
Stay Profile
This specifies the profile to be used for the stay where the standard manufacturer's stay is not to be used. The stay, and its associated data is defined in the data files. Please contact Tekla Structures support if you need to add any extra ones.
Standard manufacturer's stay from the data files. 
Stay AssemblyThis sets the assembly prefix for the stays defined in the joint.The default is set to CR. 
Stay Plate, tThis sets the thickness of the plate to the rafter / stanchion used with the rafter stays.This value will come from the data files. 
Stay Plate, bThis sets the width of the plate to the rafter / stanchion used with the rafter stays.This value will come from the data files.
Image
tekla-structures-parts-tab-stay-plate-b.png
Stay Plate, hThis sets the length of the plate to the rafter / stanchion used with the rafter stays.This value will come from the data files.
Image
tekla-structures-parts-tab-stay-plate-h.png
Stay Cleat ProfileThis specifies the profile to be used for the stay cleats. To specify stay cleats you may either enter the name of any profile stored in the profile database or use a parametric profile to create the required profile for the stay cleat.If no profile name is entered the stays will be assumed to be connected to the rafter using stay plates. 
Stay Cleat LengthThis specifies the length of the stay cleats defined in the joint.This value only applies if a valid stay cleat profile name has been given in the field above. 
StiffenerTo override the stiffener part position numbers use the Pos_No values featured below.  
Stiffener, tThis sets the thickness of the stiffener plate, which can be used in fabrication to fix the angle of the wing plate.The default setting is 10mm. 
Stiffener, bThis sets the width of the stiffener plate if required.The default setting is 60mm. 
Stiffener, hThis sets the length of the stiffener plate if required.The default setting is the height of the cleat. 
Pos_No
(Part position number)
The part position number consists of a prefix and a start number.
1. Prefix
2. Start number
Some connections have a second row for the part position number where you can enter the assembly position number.
The part position number defined in the connection dialog box overrides the settings defined in the components settings in File menu --> Settings --> Options.
Image
tekla-structures-parts-tab-pos-no.png
MaterialThis is the material grade that will be used for all the parts within the connection.The default value for this is taken from ‘Setup Preferences: Joint part material’ 
NameOnly the stay plate name can be modified.  

See also

CMF cold rolled - Important information