BW Standard Anti-Sag Bay (53) - Parameters tab

Tekla Structures
Not version-specific
Tekla Structures
Environment
Not environment-specific

Use the Parameters tab in the BW Industries' Standard Anti-Sag Bay Properties panel to control how the connecting members are defined within Tekla Structures.

Image
tekla-structures-bw-53-parameters-tab.png

 

OptionDescriptionDefaultOther

Direction of Spring Fixes
(Top-> Bottom, Bottom-> Top, Default)
This defines how the spring fixes are fitted. For example, going up the roof top->bottom would cause them to be fitted between the top hole of the first purlin and the bottom hole of the second purlin.The default direction will be determined appropriately from the roof pitch data to give the standard BW arrangement for the bay length. 
Type of Anti Sag (Apex Tie, Apex Angle Brace)This specifies the type of connecting member to be used for the anti sag where the standard manufacturer's is not to be used. If Apex Tie is selected spring fixes will be used.The default is set to Apex Tie. 
Number along the bayThis specifies the number of struts to place along the bay (as defined by the two rafters).This value will come from the data files. 
Place Diagonal Tie Wire atThis sets the position where diagonal tie wires will be added. This is writen as a list of bay numbers for example, 1 3 would put diagonal tie wires in the first and third bay (see image). A brace must be placed in the bay that needs a tie wire. The default behaviour is to not place any tie wires.
Image
tekla-structures-parameters-tab-place-diagonal-tie-wire-at.png
Eaves Brace to Back
(Default, No, Yes)
If the strut position interferes with the bolts then this control can be used to set the position of the strut relative to the cleatsrace. If set to Default option the strut is put to the inside of the cleats. 
The default is set to No.
Image
tekla-structures-parameters-tab-eaves-brace-to-back-no.png
No
Image
tekla-structures-parameters-tab-eaves-brace-to-back-yes.png
Yes
General Bolt GradeThis sets the standard for all bolts added by the macro excluding those which may be placed to the web of the eaves beam. The default setting is 8.8XOX. 
Eaves Bolt standard
 
This sets the standard for bolts placed to the web of the eaves beam. If this standard specifies countersunk bolts then a suitable packing plate will be added.The default setting is 8.8XOX. 
Eaves Brace stiffener
(No, Yes)
This is a simple field to indicate if the stiffener should be defined or not.The default is set to No. 
GroupThis defines the class that all parts will be included in.The default setting is 99. 

See also

BW cold rolled - Important information
BW Standard Anti-Sag Bay (53)
BW Standard Anti-Sag Bay (53) - Parts tab
Was this helpful?