The BW Industries' Non-Continuous Rail system joint is normally used when the specified column face to cladding distance is less than that possible for the standard purlin/rail joint. The joint can handle flush or recessed sheeting lines. A non-standard cleat, (either angle or tee), is welded to the column, and bolted to the rail using holes along the standard gauge lines.

Before and after

Image
tekla-structures-bw-134-before.png
 
Image
tekla-structures-bw-134-after.png

Notes

  • Any modification of the selected parts will cause this joint to be updated.
  • If specific values are entered under the Bolts tab, thus overriding the default bolt positions then non standard parts may be created.

Selection order example

  1. Column
  2. Rail