Auto Splitter

Tekla Structures
Not version-specific
Tekla Structures
Environment
Not environment-specific

Image
001


System component Auto splitter is used for the automatic placing of the splitters into rebar sets.

Back to top

Use for

SituationDescription
Image
006
Splitters placed into rebar set.
Image
007
Splitters placed into rebar set.
Back to top

Before you start

Create a rebar set.

Back to top

Selection order

1. Select the plugin "Auto splitter" in the component catalog and select the rebar set.
    The splitters are created automatically. 

2. Open the dialog window of the component "Auto splitter", select the rebar set and use the button "Create on selected objects".
    The splitters are created. 

General tab

In the "General" tab, adjust all the settings which will be applied when creating splitters on the selected rebar set.

 

Image
008

 

OptionDescription
1

Specific stock and lap length is used for the rebar sets with bar grades and sizes listed in the manufacturers file. Firstly, the length of the rebar set is checked according to the manufacturer.

 

Select the manufacturer of the reinforcement.

Options:

  • Company_A
  • Company_B
  • Company_C

 

The maximum bar lengths and lap lengths are then listed by the grade and size of the bar. 

 

If needed, you can define the manufacturer information in the AutomaticSplicingTool_Manufacturers.dat file.

You can find the file here: \Tekla Structures\<version>\environments\common\system , and edit it.

2Unspecified stock and lap length is used for the rebar sets with bar grades and sizes not listed in the manufacturers file.
Maximum length of barsDefine the maximum length of bars which should be split.
Lapping length

Define the lapping length of the splitters. The lapping length can be defined by:

  • Distance
  • Coefficient of bar diameter
3Splicing in the same cross sectionDefine which proportion of the reinforcement can be spliced in the same cross section.
Splicing symmetry

Define the symmetry that is applied when the reinforcing bars are spliced.

Options:

Image
005
Splicing offsetDefine the offset of the splice center point.
Minimum splitting distance

Define the minimum longitudinal distance between two parallel bar splices.

Options:

  • Distance
  • Coeficient of lap length
Bar position

Define the bar position.

Options:

  • Bars parallel to each other
  • Bars on top of each other
4Filter on selected objectUse filter to create splitters on the filtered rebar sets.
Create on selected objectsUse the button to apply the settings and create the splitters on selected rebar sets.

All rights reserved. No conclusions can be associated to the representation of the pictures in relation to the operating systems under which Tekla Structures runs.

This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. To view a copy of this license, visit http://creativecommons.org/licenses/by-nc-nd/4.0/ or send a letter to Creative Commons, 444 Castro Street, Suite 900, Mountain View, California, 94041, USA.