XS_AD_ELEMENT_ANGLE_CHECK_ANGLE_DIFF_LIMIT
Category in Advanced options dialog box
Analysis & Design
Use to set a limit angle between physical part and analysis model member, in order to test the validity of the analysis model. When the angle is greater than the limit, a message appears and a warning is added to the log. Small differences in angles are usual in the analysis model of a truss, for example. The default value is
10.0
.