Limitations (concrete beam and slab: EC2)

Tekla Structural Designer
2021
Tekla Structural Designer

Limitations (concrete beam and slab: EC2)

The following general exclusions apply when designing beams and slabs to EC2 in Tekla Structural Designer:

  • Moment redistribution.
  • Seismic design.
  • Consideration of fire resistance. [You are however given full control of the minimum cover dimension to the reinforcement and are therefore able to take due account of fire resistance requirements.]
  • Openings in the beam web.
  • Bundled bars.
  • Design for minor axis bending and shear.
  • Design for axial forces.

In addition, for beams classified as "deep beams":

  • all beams with a ratio of 1.5 < span/overall depth ≤ 3.0 are designed but with an appropriate Warning
  • beams with a ratio of span/overall depth ≤ 1.5 are Beyond Scope