Tekla Structures 2025 SP7

Tekla Structures
Modificado: 23 Feb 2026
2025
Tekla Structures

Tekla Structures 2025 SP7

Puede encontrar la última versión de servicio de Tekla Structures y los instaladores de entorno actualizados en Trimble Downloads.

Descargar Tekla Structures

Exportación IFC4.3 mejorada

La exportación IFC4.3 de Tekla Structures ahora incluye las siguientes mejoras para cumplir los requisitos obligatorios del sector de la construcción:

  • El esquema de exportación de IFC4.3 se ha actualizado a IFC 4X3_ADD2.

  • Ya es posible exportar la estructura de construcción (IfcSite, IfcBuilding, IfcBuildingStorey) utilizando las nuevas opciones de Tipo exportación IFC4.3 Reference view(IFC4.3) y Design transfer view (IFC4.3).

Para obtener más información, consulte Exportar en formato IFC.

TTSD-74182

Si usted es administrador de Tekla Structures

Cambios necesarios en el entorno

Deberá actualizar sus copias del archivo standard IFC4, standard.ifc4export.json, y crear archivos de configuración de conjuntos de propiedades para IFC4.3 si es necesario.

  • Vuelva a crear el archivo standard.ifc4export.json si utiliza los archivos de configuración de conjuntos de propiedades por defecto, como Design transfer view default properties.xml o Reference view default properties.xml.

Los archivos de configuración de conjuntos de propiedades actualizados están disponibles en el entorno común con los siguientes nombres:
  • Design transfer view default properties (IFC4).xml

  • Design transfer view default properties (IFC4.3).xml

  • Reference view default properties (IFC4).xml

  • Reference view default properties (IFC4.3).xml

Los archivos de conjuntos de propiedades se encuentran en ..\TeklaStructures\2025.0\Environments\common\inp.

Novedades en Dibujos fabricación en la Nube IA (Preliminar)

Colecciones: Volver a cargar dibujos ahora es más fácil

En Tekla Structures 2025 SP7 se introduce un sistema que avisa si la colección contiene dibujos que deberían volver a cargarse. En ellos, se muestra un signo de exclamación amarillo en el botón Colecciones del cuadro de diálogo Revisar creación y en el botón de opciones del cuadro de diálogo Colecciones. Cuando se muestra este icono, eso significa que en la última versión de servicio hay disponibles mejoras en la creación de dibujos que solo pueden aplicarse si los dibujos se vuelven a cargar. Además, puede usar la nueva herramienta para volver a cargar dibujos fácilmente sin necesidad de abrir los modelos relacionados.

La información del botón Colecciones también indica que hay disponibles actualizaciones de dibujos y se recomienda volver a cargarlos.

Ahora tiene dos alternativas para volver a cargar los dibujos:

  • Si desea volver a cargar los dibujos solo del modelo actual, use el botón más que ya conoce y cargue los dibujos desde Gestión documentos.
  • Si desea volver a cargar dibujos que deben volver a cargarse desde varios modelos a la vez, le recomendamos que utilice el nuevo y práctico cuadro de diálogo Actualizar colección.

Volver a cargar los dibujos es una recomendación. La creación de dibujos seguirá funcionando con normalidad, pero puede que no se implementen las últimas mejoras y correcciones de la última versión de servicio.

Volver a cargar dibujos usando Gestión documentos

Ahora puede volver a cargar dibujos a la colección activa desde el modelo actual con el mismo proceso que se sigue para añadir los nuevos.
  • Simplemente seleccione los dibujos en Gestión documentos y haga clic en el botón más en el cuadro de diálogo Colecciones, como antes.

    • Si solo hay dibujos nuevos en la selección, los dibujos se cargarán como de costumbre.

    • Los dibujos desactualizados (a los que les faltan partes, que tienen menos calidad, etc.) se omitirán en la carga.

    • Si la colección activa ya contiene otras versiones de algunos de los dibujos que está añadiendo, se abrirá un cuadro de diálogo que le preguntará cómo desea añadir los dibujos.

      Es posible que el dibujo que añade se haya creado en una versión anterior de Tekla Structures y que esté cargando el dibujo usando una versión más reciente de Tekla Structures, o que el dibujo local se haya modificado y guardado y ahora sea diferente de la versión del dibujo en la nube.

  • Seleccione qué desea hacer:
    • Eliminar y reemplazar: Elimina todas las versiones existentes de los dibujos y las reemplaza por los nuevos dibujos añadidos. La adición de dibujos con una versión más reciente de Tekla Structures no será compatible para los usuarios de versiones anteriores de Tekla Structures .

    • Añadir nuevas versiones: Añade las nuevas versiones de los dibujos. Esto no eliminará las versiones existentes de los dibujos.

Volver a cargar dibujos utilizando el cuadro de diálogo Actualizar colección

Puede gestionar y actualizar varios dibujos de forma eficiente a través de una interfaz intuitiva que organiza el contenido por modelo y permite seguir el progreso en tiempo real.

Nota: Si utiliza el cuadro de diálogo Actualizar colección para volver a cargar dibujos en el modelo abierto actualmente, le recomendamos que guarde el modelo de antemano para poder recuperar el estado más reciente de los dibujos.
  • Para volver a cargar los dibujos existentes con los datos más recientes, haga clic en el botón de opciones en el cuadro de diálogo Colecciones y seleccione la nueva opción, Volver a cargar dibujos.

    El nuevo cuadro de diálogo Actualizar colección muestra los dibujos organizados por modelo, cuyos datos de columna se pueden ordenar.

  • Defina las ubicaciones del modelo. Para mostrar solo los dibujos desactualizados, seleccione la casilla de verificación Mostrar solo dibujos que hay que volver a cargar en la parte superior. La versión de Tekla Structures que se utiliza para crear los dibujos se muestra en la columna Versión.
  • Seleccione qué dibujos desea cargar:
    • Para cargar solo los dibujos seleccionados, seleccione las casillas de verificación situadas junto a los dibujos deseados.

    • Para cargar todos los dibujos desactualizados en un modelo, seleccione la casilla de verificación situada junto al modelo.

    • Para cargar todos los dibujos desactualizados, marque la casilla de verificación Volver a cargar en la fila de título.

  • Haga clic en Actualizar y seleccione una de las siguientes opciones:

    • Actualizar colección existente: Los dibujos desactualizados de la colección se actualizarán a las nuevas versiones. Esta opción carga la última versión del dibujo y elimina el resto de versiones de ese dibujo. Esta es la mejor opción si desea mantener la estructura de su colección actual.
    • Duplicar colección existente: La colección activa se duplica y los dibujos se cargan allí. Seleccione esta opción si desea mantener separadas las versiones originales.
  • Si el modelo que contiene los dibujos que deben volverse a cargar es el mismo que el que tiene abierto, se le pedirá que guarde el modelo para aplicar los últimos cambios y continuar con la carga. Haga clic en Guardar.
  • Si el modelo se creó en una versión anterior de Tekla Structures, y lo guarda, ya no podrá abrirlo en una versión anterior de Tekla Structures. Se le preguntará si desea continuar con el proceso de guardado. Haga clic en para continuar.

Se inicia la carga y se muestra el mensaje Procesando junto a los dibujos que se están cargando. Puede seguir el proceso de carga en la parte inferior del cuadro de diálogo.

Puede cancelar todas las tareas en curso haciendo clic en Cancelar. Esto no deshará los cambios que ya se hayan realizado en la colección actual. Aparece el mensaje Proceso cancelado para todas las filas que se están procesando.

Cuando se hayan cargado los dibujos, el mensaje cambiará a Actualizado y el botón Cancelar cambiará a Cerrar.

Se muestra un mensaje de error, p. ej., cuando:

  • Falta un dibujo o no está disponible.
  • La ruta del modelo es incorrecta o no existe.
  • El dibujo está desactualizado o se ha producido un error de extracción.
  • Se han producido algunos errores técnicos.

Para obtener más información, consulte Gestionar colecciones y bibliotecas de dibujos de fabricación.

TTSD-71449, TTSD-69713, TTSD-70095, TTSD-70263, TTSD-71994, TTSD-72288, TTSD-72992, TTSD-73629

Otras mejoras en Dibujos fabricación en la Nube IA

  • Anteriormente, no se podían volver a cargar dibujos manualmente desde Gestión documentos utilizando el botón más de cuando el dibujo se había modificado o cuando se estaba realizando una carga desde una versión más reciente de Tekla Structures. Este problema se ha solucionado y ahora las nuevas cargas se realizan correctamente.

    TTSD-74129

  • Ahora, cuando todos los dibujos seleccionados para la carga están obsoletos o hay que volver a numerarlos, aparece un mensaje nuevo y más informativo en el que se pide que se actualicen los dibujos mediante Actualizar en Gestión documentos o abriendo y guardando el dibujo. El mensaje anterior era engañoso y no contenía suficientes detalles.

    TTSD-73296

  • Anteriormente, la carga del dibujo podía iniciarse con un retraso importante. Este problema ahora se ha corregido.

    TTSD-74599

Correcciones en Tekla PowerFab Connector

  • En el Historial de envíos para la exportación de Tekla PowerFab, en Emitido por ahora se muestra el nombre correcto del emisor. Anteriormente, se mostraba el nombre del usuario actual, incluso si este no era el emisor.

    TTSD-74431

  • Anteriormente, al exportar un paquete de fabricación usando Dibujos para aprobación externa con un tipo de dibujo seleccionado, se exportaban conjuntos y partes adicionales. Este problema ahora se ha corregido.

    TTSD-74449

Correcciones

Apply
Número de defecto Área de desarrollo Descripción
TSAC-9628 Concrete components

Auto splitter: In cases involving complex geometry, such as a variable height bridge deck, Auto splitter sometimes miscalculated bar lengths. This issue has now been fixed.

TSAC-9689 Concrete components

Wall layout: Previously, walls shifted when the work plane was placed on the wall layout. This issue has now been fixed.

TSAC-7849 Steel components

Cold rolled overlap (1): Previously, the component was not working correctly when the secondary parts had a ZPURLIN profile. This issue has now been fixed.

TSAC-8531 Steel components

Cold rolled overlap (1): Previously, when the stay angle was defined, the bottom bolts from the overlap were removed. This issue has now been fixed.

TSAC-9588 Steel components

Cold rolled overlap (1): Previously, stay plates were created in an incorrect location in some situations. This issue has now been fixed.

TSAC-9655 Steel components

Unfold surface (21): Previously, there was a gap between unfolded plates in some situations. This issue has now been fixed.

TSAC-9714 Steel components

Cold rolled overlap (1): Previously, some bolts from the overlap were missing when different stay type options were selected. This issue has now been fixed.

TSAC-9729 Steel components

Haunch (40): Previously, when using the Cut at upper end haunch option on the Haunch tab, the position of stiffeners was not correct. This issue has now been fixed.

TSAC-9730 Steel components

Haunch (40): Previously, when switching between a profile haunch and welded plates haunch, the position of compression stiffeners was changing. This issue has now been fixed.

TSAC-9732 Steel components

Full depth S (185): Previously, the cut for bolt clearance was created when it was not needed. This caused problems in numbering. Now this issue has been fixed.

TSAC-9741 Steel components

Haunch (40): Weld #4 is now used as a weld between the closure plate and the haunch profile. Previously, weld #8 was incorrectly used in this case.

TSAC-9789 Steel components

Stringer stanchion stiff (69): Previously, the component was not always working correctly with different rotations of the secondary part. This issue has now been fixed.

TSAC-9814 Steel components

Stiffened end plate (27): Previously, some shear tab chamfers were created with an incorrect default size. This issue has now been fixed.

TTSD-48482 Import, export, interoperability

You can now change the IFC entity for rebars. Previously, this was not possible.

TTSD-71846 Import, export, interoperability

Previously, Export TrimBIM was not working correctly when Location by was set to Work plane. This has now been fixed.

TTSD-72975 Import, export, interoperability

Earlier, when showing properties by value in the property pane, the Additional matches section could show an IFC_ENTITY_OVERRIDE property that is not supposed to be modified, making it easy for users to make a mistake. This issue has now been fixed, and now these kinds of properties are not available in the property pane editor.

TTSD-74160 Import, export, interoperability

IFC property sets: IFC property set names are no longer limited to being unique. Now multiple property sets can be created with the same name.

TTSD-74447 Import, export, interoperability

IFC4 export: Previously, some properties (Revision property, DRAWING.REVISION, DRAWING .ASSEMBLY, and DRAWING.CAST_UNIT) were not exported in the IFC4 export. This issue has been fixed.

TTSD-74584 Import, export, interoperability

Point clouds: Viewing a large point cloud with the smallest possible point size caused excessive memory consumption. This issue has now been fixed.

TTSD-74739 Import, export, interoperability

Previously, Tekla Structures closed unexpectedly while importing sketched profiles as .uel files in some specific cases. This issue has now been fixed.

TTSD-75003 Import, export, interoperability

IFC4 export: Previously, custom properties derived from assembly hierarchy were not exported through the IFC4 export. This issue has been fixed.

TPLED-400 Templates and reports

Template Editor: Grid density changes and changes involving image locations could distort images in Template Editor. This issue has now been fixed.

TPLED-413 Templates and reports

Template Editor: Color override in a row rule did not work for filled circles. This issue has now been fixed.

TTSD-74371 Templates and reports

Pull-out pictures for bent rebar meshes: The pull-out pictures for bent rebar meshes sometimes showed wrong dimensions and were skewed. The problem was caused by the modification of the input point handles for the meshes, and that has now been fixed. The Diagnose model and Repair model commands will now identify and fix the problem in the existing bent mesh objects.

TTSD-74429 Templates and reports

Dimensions for pull-out pictures for bent mesh: An advanced option, XS_REBAR_​BENT_​MESH_​PULLOUT_​DIMENSIONS_​INCLUDE_​LONGITUDINAL_​BARS, has been added to control whether longitudinal bars are taken into account in the dimensions shown in a rebar pull-out picture for a bent mesh. Set this advanced option to TRUE to take into account the longitudinal bars, and FALSE to ignore them. FALSE is the default value. This advanced option affects pull-out pictures in marks and templates.

This advanced option is located in the Drawing properties category of the Advanced options dialog.

TTSD-74469 Templates and reports

Template Editor: Sometimes the report template output fails when the rule result for a row is PageBreak(). This issue has now been fixed.

TTSD-74661 Templates and reports

Template Editor: Sometimes when a report template had rows with combine actions set to both Distinct and Combine, the output would be empty. This issue has now been fixed.

TTSD-74767 Templates and reports

In graphical templates, multiline text objects were not drawn correctly when they were rotated. This issue has now been fixed.

TTSD-74898 Templates and reports

HTML reports: Sometimes rows in html reports were output to the same line. This issue has now been fixed.

TSAC-8628 Drawings

Rebar pull-out picture and marking: Previously, dimensions were not created correctly for some specific bent shapes. This issue has now been fixed.

TTSD-69983 Drawings

Previously, when the placing method for level marks was set to Free in a drawing and the drawing was used in a multidrawing, the level mark positions were not updated correctly in the multidrawing when you moved the marks in the original drawing. This issue has now been fixed. The level marks are placed in multidrawings exactly as they are in the original drawing.

TTSD-70483 Drawings

Symbols are now positioned correctly in drawing templates. Previously, symbols were occasionally drawn slightly off from the correct location due to inaccuracies in the placement calculation.

TTSD-71870 Drawings

New settings for bending radius in rebar_config.inp

There are two new parameters, PullOutBendingRadiusDimensionUnit and PullOutBendingRadiusPrefix, in rebar_config.inp:

PullOutBendingRadiusDimensionUnit 

PullOutBendingRadiusDimensionUnit defines the unit to be used in the bending radius text in the pull-out. The options are:
0=auto
1=mm
2=cm
3=m
4=inch
5=foot and inch
6=cm or m

If PullOutBendingRadiusDimensionUnit is not set, mm is by default used for metric and inch for imperial. If PullOutBendingRadiusAsMultiplier is set to 1, it takes precedence, and PullOutBendingRadiusDimensionUnit has no impact.

PullOutBendingRadiusPrefix 

PullOutBendingRadiusPrefix defines the prefix to be used in the bending radius text in the pull-out. If it is not set, it will be defaulted to dBR=. If it is set to be empty, no prefix will be output.

The format and precision of the radius dimensions are defined by the existing settings in PullOutDimensionFormat and PullOutDimensionPrecision.

TTSD-73922 Drawings

Previously, Layout editor in drawings could stop working when you tried to move a template that no longer existed. This issue has now been fixed.

TTSD-73938 Drawings

In Layout editor in drawings, when you excluded a template from a layout, trying to replace the template caused an error. This issue has now been fixed. 

TTSD-74083 Drawings

Dragging marks in a drawing is now faster than before in models where rebar sequence numbering is used.

TTSD-74532 Drawings

Merging bolt hole marks: Earlier, it was possible to merge manually bolt hole marks for bolts with different oversized holes. This issue has now been fixed, and merging bolt hole marks with different oversized holes is no longer possible.

TTSD-74535 Drawings

Previously, Tekla Structures stopped working when performing numbering on a straight bar that had a custom hook with a 0 angle. This issue has now been fixed.

TTSD-73896 System and options

The reliability of closing Tekla Structures has been improved.

TTSD-70750 Tekla Model Sharing

Tekla Model Sharing: Now the remaining disk space is checked before a model is read in, and the read in process is stopped if there is not enough disk space.

TTSD-74010 Tekla Model Sharing

Tekla Model Sharing: Previously, when you excluded a model from the sharing service via the File menu, the confirmation message was not displayed. This issue has been fixed.

TTSD-72083 Reinforcement

For short curved rebar groups, there were slight inaccuracies in the inner and outer arc radii and other arc dimensions in rebar shape recognition and in Rebar shape manager. This issue has now been fixed.

TTSD-65071 Modeling

In some environments, the value is saved in the XML file with a comma (,) as the decimal separator when you edit the weight in the shape catalog. Tekla Structures cannot read the value because it only supports a period (.) as the decimal separator. This issue has now been fixed.

TTSD-67213 Modeling

Previously, the calendar icon and popup message for usage licenses were not displayed when Tekla Structures was started via Tekla Launcher. This has now been fixed. Additionally, the organization name is now correctly displayed in the About pane across all launch scenarios.

TTSD-70345 Modeling

Previously, APPL_ERROR_LOG was not working for log file naming. This has now been fixed.

TTSD-71056 Modeling

Now picking a point to inquire the coordinates no longer modifies the project base point unintentionally.

TTSD-72896 Modeling

When using Tekla Structures with Qnect Listener active, numbering commands were disabled. This has now been fixed, and there are no longer any conflicts between Tekla Structures and Qnect.

TTSD-73317 Modeling

Previously, when modifying the dimension value of a contour plate by entering the value, the opposite side might also be modified, even when the adjacent and modified sides were not orthogonal. This issue has been fixed.

TTSD-73397 Modeling

If a custom property was implemented so that the get function modified model objects, using this custom property in a representation filter could cause Tekla Structures to stop responding. This issue has now been fixed.

TTSD-73778 Modeling

Batch editor is now faster when handling hundreds or thousands of items. Note that if there are more than 1000 items, the properties of the assemblies will not be displayed.

TTSD-73889 Modeling

An issue has been fixed to prevent inconsistent adaptivity with child object handles that are positioned central to the modified parent object.

TTSD-73890 Modeling

Earlier, in some situations, when deleting certain macros, Tekla Structures displayed a message about a critical error. This issue has now been fixed.

TTSD-73892 Modeling

Crash related to rare characters in folder names when opening Template Editor has been fixed.

TTSD-73912 Modeling

Phases that are not valid are now detected better when copying objects from another model.

TTSD-73962 Modeling

Building hierarchy: Previously, the default value of the Top elevation property for new buildings was incorrectly set to 0.0. This resulted in zero-height buildings when you created a new building using the default values. The default Top elevation has now been restored to its original value of 20000 mm.

TTSD-74410 Modeling

Trimble Connect: When XS_FIRM and XS_PROJECT are set to a Trimble Connect folder path, local sync files will no longer be deleted if there is an API failure or outage. However, if the folder does not exist in Trimble Connect, the files will be deleted.

TTSD-74418 Modeling

Previously, multiple windows might have been opened each time that you double-clicked a plug-in in the model. This issue has now been fixed.

TTSD-74738 Modeling

The number of unnecessary log entries generated by the property pane has been reduced.

TTSD-74775 Modeling

In the property pane, when filtering properties using the search, the entries in the additional matches group did not always enable the Modify button. This issue has been fixed.

TTSD-73820 Licensing

In the Close Tekla Structures and Save Model dialog that is shown when a user is working offline and their computer's clock is inaccurate by more than 5 minutes, the width of the button was too small for the length of the text in some languages, such as Russian and German. The button width has now been fixed.

TTSD-71985 Core

Sometimes, Tekla Structures could freeze on startup. This has now been fixed.

TTSD-74783 Core

A rare crash related to error reporting has now been fixed.

TTSD-75083 Core

Previously, in very rare cases, Tekla Structures might have unexpectedly stopped working when setting a viewpoint. This has now been fixed.

TTSD-53365 Tools and components

An issue was fixed where nesting specific components, such as adding component A inside component B and vice versa, could cause Tekla Structures to crash. The logic has been updated to prevent this circular behavior and ensure model stability.

TTSD-73893 Tools and components

Previously, applications and plug-ins that use model history (history.db), such as Design group numbering, could cause critical errors when run on models saved using the Save as command. This issue has now been fixed.

TTSD-75074 Tools and components

Tekla Warehouse: Security has been improved through minor updates.

TTSD-74259 Numbering

Previously, the message "Numbering rebar sequences..." remained visible on the status bar after numbering was done. Now the message is removed when the Numbering preview dialog is opened.

TTSD-74312 Import, export, interoperability (steel)

DSTV/NC: Earlier, when exporting a polybeam plate having a length larger than width and advanced option XS_USE_NEW_PLATE_DESIGNATION set to a value requiring to switch the width and length, the bending lines were created too short. This issue has now been fixed.

TTSD-74340 Import, export, interoperability (steel)

STEP/IGES export: Cold rolled L profiles are now successfully exported in the STEP format.

¿Le ha resultado útil?