TSAC-1027 |
Concrete components |
Floor layout: Slab direction modification has been changed to maintain the default offset values at each layer when the slab direction is changed or rotated. |
TSAC-1948 |
Concrete components |
Floor layout: Geometry calculation has been improved in situations when openings are collinear but not overlapping to any edge at the seam. |
TSAC-2321 |
Concrete components |
Floor layout: Previously, the CIP filler part at the seam was not created properly if the slab edge had a rather large chamfer or notch at the top or bottom corner of the edge. This has now been fixed. |
TSAC-2384 |
Concrete components |
Wall layout connector, Wall layout T connector: Previously, an opening with a filler part close to the wall edge could cause the connectors to behave incorrectly. This has now been fixed.
|
TSAC-2637 |
Concrete components |
Floor layout: Seam modification has changed so that all zero seam gap dimensions are now shown when any of the seam gaps has a value other than zero.
Note that in this situation the first and last zero dimensions are also shown, and if you change either of them to some other value than zero, the setting No gap at first and last on the General tab is changed to allow a non-zero gap at the first and last seam. |
TSAC-3274 |
Concrete components |
Floor layout: Previously, part ends that had two or more slightly skewed end edges were not properly straightened or cut. This has now been fixed. |
TSAC-3992 |
Concrete components |
The Floor layout dialog box is now more compatible with 4K screens and font scaling.
|
TSAC-4103 |
Concrete components |
Wall layout connector has been improved. Now the connector's L corners work for wall layouts with different top and bottom heights. The corner item's top and bottom are matching only where the walls connect. |
TSAC-4151 |
Concrete components |
Floor layout: On the Layer tab, you can now use the leftmost check box to control if the number of the layers and the order of the layers are modified when you modify the Floor layout component.
|
TSAC-4271 |
Concrete components |
Floor layout: When picking points to create the floor layout, Floor layout now uses the work plane instead of the view plane, when the work plane is set. |
TSAC-4403 |
Concrete components |
Floor layout: Previously, break lines were not properly handled if they were collinear with some of the exterior input polygon edges. This has now been fixed. |
TSAC-4498, TSAC-3588 |
Concrete components |
Wall layout: Opening offsets are now used when the opening is part of the element outline. Note that if you want to have the door step in only one layer and not in all layers, you need to add the door opening with the door step, remove the door step from the other layers by offsetting, and make the opening large enough to cut the door step off. |
TSAC-4630 |
Concrete components |
Floor layout: Previously, a slab that had a skewed end was not created at all if the width of the slab was less than the minimum neck width. This has now been fixed. |
TSAC-4984 |
Concrete components |
Floor layout: CIP filler does not anymore create filler parts with a width less than the given minimum width at break lines, seams, and areas where the actual slab geometry differs from the required geometry (because of constraints caused by the slab profile and/or advanced options).
Note that this change does not affect the creation of filler parts at offset areas as these have never been created if the actual width is less than the given minimum width. |
TSAC-5042 |
Concrete components |
Floor layout: Checking the minimum/maximum lengths and the minimum width of all precast layers has been improved. |
TSAC-5099 |
Concrete components |
Floor layout: Previously, holes and cuts that should have been created automatically were not created if the cutting part was located in the negative offset area, that is, outside the input polygon. This has now been fixed.
|
TSAC-5120 |
Concrete components |
Hole generation (32): Rebar sets in a part will now be automatically cut. |
TSAC-5289 |
Concrete components |
Wall layout: Previously, the detailing component applied on the top side of the wall was also created on the bottom side of the wall if the height of the wall was lower than 100 mm. This has now been fixed. |
TSAC-5569 |
Concrete components |
Wall layout: Direct modification of wall boundaries now allows you to remove specific detailing. By using the No detailing option from the contextual toolbar drop-down list, you can directly remove the side, top, and bottom edge detailing. |
TSAC-5737 |
Concrete components |
Concrete beam-beam (112): You can now use the Create washers symmetrically setting on the Anchors tab to define whether the washers on the anchors are created symmetrically (mirrored) to the washers on the anchors at the opposite beam side. |
TSAC-5753 |
Concrete components |
Embedded Anchors (8): The Avoid reinforcement setting on the Placement tab now detects all rebars in collision with each created anchor and moves the anchors out of the collision with a cover thickness. Also, the detection works in the range of the anchor bounding box + the desired cover thickness.
|
TSAC-5764 |
Concrete components |
Floor layout: Slab and seam modification has been improved to work more consistently when changing the width of the first or last slab. |
TSAC-5808 |
Concrete components |
Floor layout: Previously, when creating automatic cut-outs for I-shaped columns, only a small cut was created at one flange if the I shape web was not touching the slab. This has now been fixed. |
TSAC-5860 |
Concrete components |
Wall panel reinforcement: The calculation of spacing at the edges has been improved. |
TSAC-6020 |
Concrete components |
Embedded anchors (8): Previously, the anchor position was not correct when the distance between two anchors based on the a dimension was set to zero (0.00) on the Placement tab. This has now been fixed. |
TSAC-6042 |
Concrete components |
Wall panel reinforcement: Previously, Tekla Structures could stop responding when you used the component in walls that contained openings. This has now been fixed. |
TSAC-6071 |
Concrete components |
Embedded anchors (8): On the Placement tab, the Move to closest braced girder setting now works properly when creating multiple anchors in the cross direction. |
TSAC-6073 |
Concrete components |
Floor layout: The Floor layout dialog box now opens correctly when you specify that there are no UDAs listed on the User defined tab. Previously, you had to have at least one UDA on the User defined tab. |
TSAC-6090 |
Concrete components |
Wall panel reinforcement: Previously, the hook length on the door opening sides was not correctly created. Now the correct length is used. |
TSAC-6117 |
Concrete components |
Embedded anchors (8): On the Placement tab, Avoid reinforcement and Move to closest braced girder now move anchors in the center of gravity (COG) direction, and multiple anchors are moved symmetrically. All anchors are no longer moved in one direction. |
TSAC-6118 |
Concrete components |
Embedded anchors (8): The Avoid reinforcement -> Cover thickness setting on the Placement tab is now used properly for clash detection. Previously, the bars that were not clashing but were still in the cover thickness area were not taken into account. Now the anchors are also offset by the correct distance from those bars. |
TSAC-6137 |
Concrete components |
Floor layout: Previously, locked seams moved when deleting the seams between the locked seams. This has now been fixed. |
TSAC-6138 |
Concrete components |
Floor layout: Previously, even if you had selected the No gap at first and last option on the General tab, the zero starting gap was not applied if any of the widths was changed and/or when the seams were moved using direct modification. This has now been fixed. |
TSAC-6156 |
Concrete components |
Floor layout: It is now possible to use negative/small offsets in other layers than the primary layer at the start/end of the layout.
In addition, input polygon modification has been improved to maintain the offset if a new point is added or removed. |
TSAC-5466 |
Steel components |
Base plate (1042): Previously, the distances from the flange of the main part to the edge of the base plate were swapped in the component. This has now been fixed. |
TSAC-5545 |
Steel components |
Railings (S77): Previously, railings were incorrectly created on inclined stanchions. This has now been fixed. |
TSAC-5551 |
Steel components |
Railings (S77): On the Parameters tab, you can now select in the Other rail to stanchion fitting list that rails are cut by the stanchions without any tolerance.
|
TSAC-5572 |
Steel components |
Round tube (23): Previously, the fitting of the secondary part was created incorrectly in some orientations of the secondary part. This has now been fixed. |
TSAC-5602 |
Steel components |
Splice plate 2 (62): Previously, the primary web bolts assembly was not applied correctly. This has now been fixed. |
TSAC-5918 |
Steel components |
Auto bolt: If a successful instance of the Auto bolt component is modified in a way that would cause failure or no bolts to be created, the previously created bolts are now removed. In addition, a warning message is shown on the status bar, as previously. |
TSAC-5966 |
Steel components |
Railings (S77): You can now select the custom component direction for the start and end closure on the Panels tab. |
TSAC-5981 |
Steel components |
Auto bolt: When the bolt group shape is set to xy list, the bolts are no longer offset from the bolt group origin. |
TSAC-6057 |
Steel components |
Stiffened end plate (27), Partial stiffened end plate (65): Previously, bolt edge distances were incorrectly applied in the component. This has now been fixed. |
TSAC-6097 |
Steel components |
Full depth (184): Previously, some notch cuts were created with infinite length. This has now been fixed. |
TSAC-6170 |
Steel components |
Bolted gusset (11): Previously, chamfers were not created correctly in the gusset plate. This has now been fixed.
|
TSAC-6188 |
Steel components |
Inner diaphragm (1059): Previously, the Finish property of the diaphragm plate was not set correctly. This has now been fixed. |
TSAC-6195 |
Steel components |
Bolted gusset (11): The round notch shape is now created correctly, regardless of the defined notch length. |
TSAC-6196 |
Steel components |
Z pan (S74): Previously, the top landing was not created with the correct length. This has now been fixed. |
TSAC-6258 |
Steel components |
Shear plate built-up T (69): Previously, assembly numbering for parts was not correct. This has now been fixed. |
TSAC-5023 |
Task Manager |
Previously, Task manager stopped working if you tried to print a scenario when there was no printer installed on the system. This has now been fixed. |
EPM-4558 |
Import, export, interoperability |
Export to Tekla EPM: CNC files that are copied during the export are now preserved in the same directory structure they were copied from.
|
EPM-5052 |
Import, export, interoperability |
Export to Tekla EPM: Exporting to Tekla EPM from an assembly selection in the Tekla Structures model is now supported. |
EPM-5537 |
Import, export, interoperability |
Export to Tekla EPM: The Standard settings are now reloaded when the window is closed and reopened. |
EPM-5692 |
Import, export, interoperability |
Export to Tekla EPM: A field has been added to the XML file exported from Tekla Structures, telling what version of the plugin was used to create the file. |
EPM-5717 |
Import, export, interoperability |
Export to Tekla EPM: If no settings file is found when you run the plug-in, one is automatically created with default options. |
EPM-5718 |
Import, export, interoperability |
Export to Tekla EPM: The Save button did not save the current settings correctly. This has now been fixed. |
EPM-5744 |
Import, export, interoperability |
Export to Tekla EPM: PROJECT.NUMBER can now be included in advanced settings to print drawings, and will be found when those drawings are copied into the zip file exported to Tekla EPM. |
TTSD-44018 |
Import, export, interoperability |
IFC2x3 export: Previously, additional property sets did not work on reinforcing meshes. This issue has now been fixed. |
TTSD-47437 |
Import, export, interoperability |
Reference models: Inserting an IFC model as a reference model was slow in a certain use case. This issue has now been fixed. |
TTSD-47531 |
Import, export, interoperability |
IFC2x3 export: Bolt and weld colors are now correct when you export with or without current view colors, or using user-defined colors, or colors defined by class. |
TTSD-48082 |
Import, export, interoperability |
Previously, you could not export IFC4 property sets for location breakdown structure properties (for example, LOCATION_BREAKDOWN_STRUCTURE.LBS_FLOOR). This issue has now been fixed. |
TTSD-48184 |
Import, export, interoperability |
Tekla Structures now supports SketchUp version 2021. |
TTSD-48719 |
Import, export, interoperability |
A Tekla Structures application error occurred when you modified reference model data when the reference model file name or the file name path contained special characters. This issue has now been fixed. |
TTSD-48988 |
Import, export, interoperability |
Trimble Connect: Operations could fail due the authorization token expiry. This has now been fixed. |
TTSD-49006 |
Import, export, interoperability |
The mapping of the IFC property Profile name now supports using either "EXTERNAL.profile name" or "EXTERNAL.profilename". Now you can also use translated strings in mapping product and profile attributes for Profile name, Description, Ifc type (type), Object type, Phase, Material, Finish, Profile, and Name. For example, you can use the German string "EXTERNAL.Profilname" and it works. |
TTSD-49708 |
Import, export, interoperability |
IFC object conversion: Now the conversion works better also when IFC object contains boolean parts (boolean adds and cuts). |
TPLED-213 |
Templates and reports |
The Valuefield did not give a correct result when the formula had a CopyField() function and used directly or by a reference the ROW_IN_PAGE attribute. This issue has now been fixed. |
TPLED-217 |
Templates and reports |
Template Editor: Circles in an imported DWG image sometimes had an incorrect color, and filled polylines could be missing. This has now been fixed. |
TPLED-224 |
Templates and reports |
Sometimes, CopyField() did not copy the correct value if the source valuefield was in a row that was combined. This issue has now been fixed. |
TPLED-228 |
Templates and reports |
Template Editor: Sometimes, the CopyField() value was not retrieved correctly from a row previously output. This issue has now been fixed. |
TTSD-47553 |
Templates and reports |
A graphical field that uses the PLATE_TOP_VIEW attribute now works correctly also when the plates are located vertically in the model. |
TSAC-5394 |
Drawings |
Rebar pull-out picture and marking: The hook representation has been improved, and 135 and 180 degree hooks are now correctly visualized. |
TSAC-5509 |
Drawings |
Rebar pull-out picture and marking: Rebar pull-out picture and marking now supports rebar strands. |
TSAC-5916 |
Drawings |
Rebar pull-out picture and marking: The rotation of the rebar sets has been improved. Previously, the rotation of the pull-out was not always matching the bar in the drawing. |
TSAC-6013 |
Drawings |
Drawing dimensioning performance has been significantly improved when you use the Filter dimensions method to dimension reinforcement. |
TTSD-38577 |
Drawings |
Text with default font in symbols was not visible in printing in some cases. This has now been fixed. |
TTSD-41841 |
Drawings |
PDF reports with images on each page quickly became very large the more pages there were. This issue has now been fixed. |
TTSD-44484 |
Drawings |
Document manager: Drawings with container views now work correctly with the Select objects in the model for selected drawings command.
|
TTSD-44486 |
Drawings |
Sometimes, pull-out pictures were not rotated correctly in drawings. This has now been fixed. |
TTSD-45025 |
Drawings |
Layout editor: Layout editor now allows you to edit the size width and height by selecting the appropriate cell and pressing the Enter key. |
TTSD-45477 |
Drawings |
When using the on/off button in the old drawing view properties dialog boxes, not all the check boxes in the dialog box changed their state. This issue has now been fixed.
|
TTSD-45701 |
Drawings |
Previously, sometimes when you unfold drawings, Tekla Structures stopped working unexpectedly. This has now been fixed. |
TTSD-47191 |
Drawings |
Printing: Previously, printing would fail if there were any errors in the TeklaStrutures.lin line type file, now any unrecognized lines will be ignored. Unrecognized line styles will be logged and drawn with a solid line, matching the drawing editor. |
TTSD-47421 |
Drawings |
Reading dimensioning rule files from relative folders using advanced options XS_FIRM and XS_PROJECT is now possible. For example, XS_FIRM=".\ts" can be used to read files from the 'ts' folder inside the model folder. |
TTSD-47570 |
Drawings |
Printing: Symbols located in paths containing non-Latin characters did not always appear in printouts. This issue has now been fixed. |
TTSD-47839 |
Drawings |
In the old Single-part drawing properties dialog box pressing the on/off button did not change the state of the Weld mark check box. This issue has now been fixed. |
TTSD-47853 |
Drawings |
Layout editor: The template width was not calculated correctly for a template with a variable number of columns, which caused the anchoring point to not adjust correctly. This has now been fixed. |
TTSD-47863 |
Drawings |
A staircase component has in one occasion caused invalid geometry to a part, causing the drawing containing the part to freeze during the drawing opening. This has now been prevented. |
TTSD-47914 |
Drawings |
Earlier, when a bolt had a regular and an oversized hole in different parts, the oversized hole was not always shown correctly in section views. This has now been fixed. |
TTSD-47929 |
Drawings |
Weld marks now work better when you copy a drawing to a new drawing sheet. |
TTSD-48164 |
Drawings |
Document Manager: Document Manager was not updated to reflect the file changes in the watched subfolders. This issue has now been fixed. |
TTSD-48603 |
Drawings |
Perpendicular rebar symbols are now drawn correctly even if the other end of the rebar segment was hidden by a part. |
TTSD-48613 |
Drawings |
Dimension associativity: Dimension associativity rules for weld preparation cuts now show a correct label instead of an empty text. |
TTSD-48862 |
Drawings |
Master drawing catalog: The Create bar code labels rule set works again. This rule set comes with the default environment. |
TTSD-49034 |
Drawings |
Earlier, the on/off switch in the General arrangement drawing properties dialog box did not work for pour-related settings. This has now been fixed. |
TTSD-49091 |
Drawings |
In some rare cases, Tekla Structures stopped working when it was updating weld mark placing in drawings. This issue has now been fixed. |
TTSD-48090 |
Tekla Model Sharing |
Previously, in some rare cases, there was an application error in Tekla Structures when reopening a shared model, for example. This has now been fixed. |
TTSD-35590 |
Reinforcement |
Previously, Cyrillic characters were not shown correctly in the rebar catalog even when the Russian locale was set in Windows. This resulted in the property pane showing Cyrillic characters incorrectly and reinforcement objects failing in the model. This issue has now been fixed. |
TTSD-43562 |
Reinforcement |
Previously, in the US Imperial environment, selecting a reinforcement mesh and clicking OK in the Select mesh dialog box caused longitudinal and cross distances be shown in metric units. This has now been fixed. |
TTSD-46706 |
Reinforcement |
Previously, when opening the reinforcement mesh catalog in the US Imperial environment, distances were shown in metric units, and it took some time before they switched to imperial units. This now has been fixed. |
TTSD-19953 |
Modeling |
Previously, the Weight per unit length property was always shown in metric units in custom inquire. This has now been fixed. |
TTSD-45563 |
Modeling |
Previously, in some rare cases lofted plates with arc base curves did not get the base curve manipulator when they were selected. This has now been fixed.
|
TTSD-45631 |
Modeling |
Previously, Tekla Structures could close unexpectedly because of corrupted bitmaps on the contextual toolbar. This has now been fixed. |
TTSD-46233 |
Modeling |
Previously, when an assembly was inquired, the highlight colors for the main and secondary objects were not set correctly. This has now been fixed. |
TTSD-47330 |
Modeling |
In some cases, when XS_ENABLE_POUR_MANAGEMENT was set to TRUE and after the Repair model command was used, reinforcement objects could not be added to pour units using the Calculate pour units command. This does not happen anymore. |
TTSD-47462 |
Modeling |
Previously, modifying concrete panels could sometimes cause Tekla Structures to close suddenly. This has now been fixed. |
TTSD-47792, TTSD-48445 |
Modeling |
Previously, in the US Imperial environment, the maximum possible supported precision for bolt size was 1/16. This resulted in incorrect bolts being added to the model from the bolt catalog. Now the precision has been increased to 1/128. |
TTSD-47983 |
Modeling |
Previously, it was not possible to save or load surface treatment pattern properties or user-defined attributes in the property pane. This issue has now been fixed. |
TTSD-48110 |
Modeling |
When you use the template attribute PROFILE.WEIGHT_PER_UNIT_LENGTH in filtering, it now follows the unit settings. Previously, it always showed the values in metric units. |
TTSD-48510 |
Modeling |
Sometimes when loading bolt properties from a file in the US metric environment, the bolt size was not set correctly in the property pane. This issue has now been fixed. |
TTSD-48546 |
Modeling |
Lofted plate geometry for antimaterial and addmaterial was removed during a database repair, if XS_DELETE_UNNECESSARY_INT_ARRAYS was set to TRUE. This led to corrupted antimaterial/addmaterial and to a failed solid of the part influenced by the antimaterial/addmaterial. This issue has now been fixed. Additionally, these errors are now reported when models with already removed geometry are being diagnosed.
|
TTSD-48560 |
Modeling |
Previously, some components, other tools, or commands could create locked dummy objects in the model and unlocking the objects was not possible. Now, the dummy object locks are ignored and the objects follow their parent object behavior. |
TTSD-48751 |
Modeling |
Previously, when using the Open properties command for grid lines on the contextual toolbar, both the old Grid line properties dialog box as well as the property pane was shown. This has now been fixed. |
TTSD-48896 |
Modeling |
Previously, property pane stopped working unexpectedly when more than 200 surface treatments were selected. This has now been fixed.
|
TTSD-49184 |
Modeling |
When you use the Insert into model feature, the Tekla Warehouse Installer now detects shapes that have similar names to shapes that already exist in the model to better prevent accidentally overwriting the existing shapes. |
TTSD-47254 |
Installation |
Previously, when trying to install an environment, there could be an error in .tsep file installation if the user's computer was configured to use a virtual desktop. The folder path to the virtual desktop could not be accessed and the .tsep package validation did not succeed. This issue has now been fixed and the installation now continues. Note that .tsep shortcuts cannot be created on the virtual desktop. If the .tsep requires a shortcut, instructions about adding the shortcut manually will be added to the installation log. |
TTSD-39986 |
Tools and components |
Custom components with bent plates, spiral beams, or parts with asymmetric profiles now mirror correctly when you use the Copy - Mirror command.
|
TTSD-48024 |
Tools and components |
Previously, the Applications & components catalog could stop responding to mouse clicks if you pressed the Home or End key while using the catalog. You could not select any groups or items in the catalog, for example. This has now been fixed. |
TTSD-49506 |
Import, export, interoperability (steel) |
NC export: Earlier, when exporting a part containing a non-circular hole, it was exported as a circular hole in the BO block. This has now been fixed. |
TSAC-5756 |
Import, export, interoperability (concrete) |
Export ELiPLAN file (68): Previously, net area was exported incorrectly for some elements with certain types of cuts or recesses. This issue has now been fixed. |
TSAC-5990 |
Import, export, interoperability (concrete) |
Export Unitechnik (79): The line attribute override with surface objects now works also when the Output file structure option on the Main tab is set to 1 slabdate, scanned layers, and the main part edge is not at the cast unit boundary. |
TSAC-6009 |
Import, export, interoperability (concrete) |
Export Unitechnik (79): Previously, in some cases, the line attribute override from surface object applied into an incorrect concrete edge when the object faces were complex. This issue has now been fixed. |
TSAC-6026 |
Import, export, interoperability (concrete) |
Export EliPLAN file (68): The data conversion file can now be read from the XS_FIRM and XS_PROJECT folders. Export Unitechnik (79): The special export assembly file names and reinforcement definition file can now be read from the XS_FIRM and XS_PROJECT folders. |
TSAC-6027 |
Import, export, interoperability (concrete) |
Export Unitechnik (79): Previously, mesh turned to pallet plane failed with some mesh within stair elements. Also, when you exported multiple cast units with surface objects designated as pallet base, the elements were exported incorrectly. This issue has now been fixed. |
TSAC-6065 |
Import, export, interoperability (concrete) |
Export Unitechnik (79): You can now export iron projection data using the new Iron projection setting on the SLABDATE block data specification tab. The values are automatically determined from reinforcement length that extends outside the element. The Special formwork for embed setting has been renamed to Special formwork for object, and now this setting also works for reinforcement specified by class or by name. |
TSAC-6094 |
Import, export, interoperability (concrete) |
Export ELiPLAN file (68): Previously, weep holes were exported incorrectly when hollowcore was cut by its longer side. This issue has now been fixed. |
TSAC-6143 |
Import, export, interoperability (concrete) |
Export ELiPLAN file (68): Previously, cast unit main part material could not be filtered out by the Material quantities setting on the Parameters tab. Now the filtering works correctly. |
TSAC-6144 |
Import, export, interoperability (concrete) |
Export ELiPLAN file (68): Data conversion now supports case insensitive text, which means that it does not distinguish between uppercase and lowercase letters when looking for strings to be replaced. |
TSAC-6296 |
Import, export, interoperability (concrete) |
BVBS Export: When 2D reinforcing bars had bendings in both directions in recent service packs, the bendings to negative directions were not considered, and were exported as straight sections. This issue has now been fixed. |
TTSD-48872 |
Common |
Tekla Structures closed suddenly if you inquired a spiral beam that had a zero rotation angle. You can now create the inquiry. In general, you should not create a spiral beam with a zero rotation angle. |