Número de defecto | Área de desarrollo | Descripción |
---|---|---|
TSAC-1281 | Concrete components | In Wall layout and Floor layout, when a user-defined attribute value on the UDA/User defined tab is empty, the components now ignore these empty values. This lowers the risk of overwriting these UDAs. |
TSAC-1859 | Concrete components | Previously, Wall layout tools used the circular opening settings for rectangular openings if a circular opening was modified before creating the rectangular opening. This has now been changed. |
TSAC-2501 | Concrete components | In Electric box in wall (84), distance parameters now work properly with imperial units. |
TSAC-2850 | Concrete components | In Floor layout, you can now use Chinese characters in layer names. |
TSAC-2896 | Concrete components | In Embedded anchors (8), you can now define a rounding value for anchor distances on the Placement tab. |
TSAC-3000 | Concrete components | In Sandwich and double wall, all foils and insulations that are split are now added to the cast unit as defined on the Parts tab. |
TSAC-3023 | Concrete components | In Reinforced concrete stair (95), the STAIR_WIDTH_TOTAL user-defined attribute is now calculated properly. |
TSAC-3041 | Concrete components | In Mesh bars, extra secondary bars are no longer created in centrally placed bar groups. |
TSAC-818 | Concrete components | Mesh bars: You can now set the bar edge distance as a negative value. Note that this will only offset the bars. To get a fully offset mesh, set the cover thickness for the sides on the Bar end conditions tab to a negative value. |
TSAC-1069 | Steel components | Cold rolled sleeved (2): It is now possible to select the bolt size and bolt standard from catalogs. |
TSAC-1528 | Steel components | Cold rolled sleeved (2): The sleeve profile is now included in the bolted parts. |
TSAC-2177 | Steel components | In H/V Shear plate (64), previously there was the gap or clash between the shear plate and the main part. This has now been fixed. |
TSAC-2807 | Steel components | Bolted gusset (11) now works in the same way in different Tekla Structures versions. |
TSAC-2933 | Steel components | In Welded column with stiffeners (128), top and bottom stiffener welds were previously swapped. This has now been fixed. |
TSAC-2990 | Steel components | In Simple clip angle 2 (82), the copes were previously created incorrectly causing problems with dimensioning in the drawings. This has now been fixed. |
TSAC-2991 | Steel components | In L splice (175) there was an incorrectly created chamfer on the L profile, which was causing problems with numbering. This has now been fixed. |
TSAC-3010 | Steel components | Cranked beam (41): Vertical positioning of the bolt groups is now working correctly. |
TSAC-3054 | Steel components | Column with stiffeners (188): Shear tabs are now correctly placed when the main part is created from plates. |
TSAC-3140 | Steel components | In Gusseted cross (62), the bolt cut length was too small for thick gusset plates. This has now been fixed. |
TSAC-3160 | Steel components | In Wraparound gusset cross (60), the bolts were rotated incorrectly when the connection was used for twin profiles. This has now been fixed. |
TSAC-3177 | Steel components | Cold rolled overlap: Previously, when using user-defined profiles as secondary parts, the cleat was positioned incorrectly. This has now been fixed. |
TSAC-3185 | Steel components | In Railings (S77), stanchion skews are now created correctly for all stanchions. |
TSAC-3204 | Steel components | Bolted moment connection (134): Flange plate clearance now works correctly when the connection is connected to the main part web. |
TSAC-3253 | Steel components | In Stiffened base plate (1014), you can now define the material of extra profiles on the Extra plates tab. |
TSAC-3271 | Steel components | Column splice (132): You can now define the number of web bolts when using a division plate and angle profiles as the connection. |
TSAC-3295 | Steel components | Splice connection (77): Weld preparations for web plates are now created correctly and do not cause solid errors anymore. |
TSAC-3312 | Steel components | Joist to column, type 2 (163): Stabilizer angle bolts are now created when the secondary part is sloped. |
TSAC-3320 | Steel components | Cold rolled overlap (1): The cleat is now created correctly when using an L profile. |
TSAC-3323 | Steel components | Cold rolled sleeved (2): Bolt spacing is now correctly applied when the gap between the purlins has been specified. |
TSAC-3326 | Steel components | Seat detail type 1 (1033): If the system default value is not found, the default material is now correctly set from File menu > Settings > Options > Components. |
TSAC-3336 | Steel components | Create hole around part (92): Previously, when the profile length was shorter than the profile height, the cut was created incorrectly. This has now been fixed. |
TSAC-846 | Steel components | In Rebar hole, holes are now created correctly for inclined reinforcing bars with part cuts in steel columns, beams, and contour plates. |
TTSD-20302 | Organizer | In Organizer, when you used the W_Project_data property template, the property values of one assembly row in Object Browser were emptied when you exported the object properties to Excel. This has now been fixed. |
TTSD-27599 | Organizer | Synchronization has been improved in Organizer. Synchronizing Organizer with models that have assemblies containing a lot of subassemblies/parts is much faster than before. |
TSAC-2653 | Task Manager | Previously, changing the parent task of a task by decreasing the indent could cause some other tasks to be deleted in Task manager. This has now been fixed. |
TTSD-15289 | Import, export, interoperability | DWG drawing export: 2D DWG export now scales the exported file correctly also when US Imperial units are used in the model. |
TTSD-26897 | Import, export, interoperability | The bending radii of rebar hooks are now correctly exported to IFC4. Previously, the main rebar bending radii were applied to all bends including hook bends. |
TTSD-27454 | Import, export, interoperability | IFC object conversion: Curved walls were not converted in the correct orientation. This has now been fixed. |
TTSD-28021 | Import, export, interoperability | IFC4 export: A non-segmented profile is now used for polygon plates. |
TTSD-28680 | Import, export, interoperability | DWG drawing export: Previously, the Export drawings to DWG/DXF dialog box would not open if the advanced option XS_DRAWING_PLOT_FILE_DIRECTORY had no value. This has now been fixed. |
TTSD-28845 | Import, export, interoperability | DWG drawing export: It is now possible to cancel the DWG drawing export/preview. |
TTSD-28931 | Import, export, interoperability | DWG drawing export: The DWG export stability has been greatly increased in cases of exporting many drawings at a time. |
TTSD-29135 | Import, export, interoperability | IFC object conversion: The IFC object conversion changes list shows object names again. |
TTSD-29389 | Import, export, interoperability | IFC object conversion: Edge lines are now drawn again when you convert IFC items to native Tekla Structures items with the IFC object converter. |
TTSD-29494 | Import, export, interoperability | IFC2x3 export: The export now uses assembly name for steel parts as well. |
TTSD-29888 | Import, export, interoperability | IFC export: Previously, exporting a polybeam with a chamfer of over 180 degrees using 3 points did not work correctly. This has now been fixed. |
TTSD-22294 | Templates and reports | Template Editor: Numbers that exceed the length field of a template are now correctly truncated with * symbols |
TSAC-2869 | Drawings | Rebar group dimensioning: Rebar groups are now dimensioned in polybeams. |
TSAC-3003 | Drawings | In Rebar group dimensioning, the dimension mark and line to rebar are now correctly placed in a customized position. |
TSAC-3325 | Drawings | Rebar group dimensioning: Rebar group dimensioning no longer causes crashes. The crashes were caused by incorrect part bounding boxes and incorrectly counted view restriction boxes. |
TTSD-15807, TTSD-28271 | Drawings | A new representation option outline (ignore holes) has been added for meshes on the Mesh content tab in Reinforcement properties. Additionally, the missing representation option single line with filled ends was added on the Mesh content tab. |
TTSD-24534 | Drawings | The center-to-center distance in bolt marks now works more reliably. |
TTSD-27732 | Drawings | The update of the curved dimensions in drawings now works more reliably. |
TTSD-27776 | Drawings | Reference models: Assembly, cast unit, and single-part drawings: Previously, section symbols were created very far apart and view boundaries were too large if the model contained reference models, even when the reference models were not visible in the drawings. This has now been fixed. |
TTSD-28039 | Drawings | The CURRENT_DRAWING.TITLE property now correctly returns a value when used with Select from drawing in drawing view properties. |
TTSD-29396 | Drawings | The TOP_LEVEL_BASEPOINT value was not displayed in drawing views when the value was zero. This has now been fixed. |
TTSD-29639 | Drawings | Previously, moving part marks with leader lines could sometimes cause Tekla Structures to crash. This has now been fixed. |
TTSD-14480 | Tekla Model Sharing | Previously in Tekla Model Sharing, saving a copy of a shared model with the Save As option could erase the creation time and creator of model objects. This has now been fixed so that the creation time of model objects is the time that the copied model was saved, and the creator is the user that saved the model. |
TTSD-26837 | Tekla Model Sharing | Reference models: Previously in shared models, conflicts with reference models at read-in sometimes caused situations where reference objects could not be shown as invisible in the model view. This has now been fixed. |
TTSD-27196 | Tekla Model Sharing | Previously, when a reference model was locked locally before read in, you had to reopen the model to update the reference model version. This has now been fixed. |
TTSD-27827 | Tekla Model Sharing | The following fixes have been made in Tekla Model Sharing: - The green arrow on the Read in button is now shown correctly if there are no packets available to read in. - Previously, if model changes were written out too many times within a short time frame, Tekla Structures sometimes lost track of the changes and could not show the number of packets that users could read in. This has now been fixed. |
TSAC-2747 | Reinforcement | In Rebar shape manager, the value of total length along center line (CLL) was not correct in case the bending radius values and angles were varying. This has now been fixed. This fix also affects reports if the CLL value has been used for calculations. |
TTSD-27047 | Modeling | Previously, if there was a conflict in a multi-user model and you clicked Review in the conflict message dialog box, Tekla Structures showed an error message when you viewed the conflict log. Now the error message is not shown anymore in conflict situations. |
TTSD-27762 | Modeling | Previously, if a bent plate had several edge chamfers, removing one of them caused others to disappear. This has now been fixed. |
TTSD-27782 | Modeling | In multi-user models, bolts could get incorrect properties in some conflict situations and thus look corrupted. This has now been fixed. |
TTSD-29032 | Modeling | In the Object Group - View Filter dialog box, the values in the Property column no longer disappear when entered with a space at the end of the value. |
TTSD-29301 | Modeling | Previously, when you had selected all parts in a cast unit with the Alt key pressed and you had the Select components selection switch active, trying to deselect a custom component sub-assembly in the cast unit by clicking the sub-assembly with the Ctrl button pressed could cause Tekla Structures to crash. This has now been fixed. |
TTSD-29400 | Modeling | Earlier, when diagnosing models containing spiral beams with a 360-degree turn and no total rise, model inconsistencies were reported. When repairing such models, these spiral beams were removed from the models. This has now been fixed. |
TTSD-29673 | Modeling | Parts whose material is Formwork_undefined are no longer added to the pour unit when you use the Calculate pour units command. However, you can manually add these parts to pour units if the cast unit type is precast. |
TTSD-29820 | Modeling | Profiles with zero decimals (for example, C130X2.0) were not shown correctly in the model (their detailed shape was lost and did not contain roundings, for example). This applied to fixed profiles which were created from sketched profiles. Now this has been fixed. |
TTSD-26713 | Core | Trimble Connector has been updated to a new version, with updated identity handling. |
TSAC-2579 | Tools and components | Sometimes, it was not possible to open the Layout line dialog box by double-clicking the thumbnail image in the Applications & components catalog. This has now been fixed. |
TSAC-653 | Tools and components | In Automatic splicing tool, single bars now apply the first splice correctly. |
TTSD-28207 | Tools and components | Previously, there was an error when publishing a custom component in the Applications & components catalog when another component of a different type with the same name as the custom component already existed. This has now been fixed. |
TTSD-18005 | User interface | You can now change the space between cut parts on the contextual toolbar in the drawing mode. |
TTSD-22777 | User interface | Previously, when you maximized the Customize toolbars dialog box, the OK, Apply, Discard and Cancel buttons at the bottom of the dialog box were not visible. This has now been fixed. |
TTSD-24308, TTSD-25929, TTSD-28663 | User interface | Previously, when you modified a UDA that did not affect numbering by using the property pane, Tekla Structures still considered the model object as needing renumbering. Now this does not happen anymore. |
TTSD-27392 | User interface | In the Object group - View filter dialog box, having spaces before or after the text in the Value field no longer causes the text to disappear. |
TTSD-27961 | User interface | Selecting the profile and the material from the profile and material catalogs in the property pane now works correctly when creating parts. |
TTSD-29452 | User interface | In some rare cases when dragging a table in Layout editor, the Tekla Structures user interface was no longer responding. This has now been fixed. |
TSAC-2527 | Import, export, interoperability (steel) | NC files: Skew cuts were not created well when were at a certain angle. This has now been fixed. |
TSAC-2540 | Import, export, interoperability (concrete) | EliPlan Export (68): Plotter data export has been improved. |
TSAC-3217 | Import, export, interoperability (concrete) | Export Unitechnik (79): In some cases, rebars exported as mountparts were plotted with double lines. This has now been fixed. |
TSAC-3219 | Import, export, interoperability (concrete) | Export Unitechnik (79): There is a new option for the Export project coordinates setting on the SLABDATE block data specification tab. Use the new Yes, special variant A option to export Unitechnik files that are compatible with the IDAT stacker software. The new option is only available for the 5.2b version of Unitechnik. |
TSAC-3357 | Import, export, interoperability (concrete) | Export Unitechnik (79): On the Reinforcement tab, you can now select to export braced girders within the STEELMAT block. By default, the braced girders are exported outside of the STEELMAT block. |