Review member design
Review member design status
- Activate a Review View by clicking Review View in the Status bar.
-
On the Review ribbon, in the Type list, select the desired design type to review.
- Static
- RSA
- Combined (i.e. Static and RSA together)
-
On the ribbon, in the Design group, click Status.
Color codes display the design status of each member using the following classifications:
Status
Description
Error
The member currently cannot be designed because an error has occurred.
Beyond Scope
The member cannot be designed because its design is beyond the scope of Tekla Structural Designer or Tekla Structural Designer/Tedds.
Fail
The member has failed one or more design checks.
Warning
Although the member has passed the design checks, one or more warnings have been issued. Review the warnings before deciding if you need to take further action.
Pass
The member has passed all design checks.
Not Yet Designed
The member has not been designed.
Review member design ratios
- Activate a Review View by clicking Review View in the Status bar.
-
On the Review ribbon, in the Type list, select the desired design type to review.
- Static
- RSA
- Combined (i.e. Static and RSA together)
-
On the ribbon, in the Design group, click Ratio.
Color codes display the design ratio of each member. N/A is assigned to members that have no ratio or whose ratio is smaller than the lowest band. N/A also indicates members that either are beyond scope or have yet to be designed.
Review member depth ratios
- Activate a Review View by clicking Review View in the Status bar.
-
On the ribbon, in the Design group, click Depth Ratio.
All beams are color coded to indicate their span to depth utilization ratios.