XS_MAX_MERGE_DISTANCE_IN_HORIZONTAL

Tekla Structures
Modified: 28 Oct 2024
2025
Tekla Structures

XS_​MAX_​MERGE_​DISTANCE_​IN_​HORIZONTAL

Category in Advanced options dialog: Marking - parts

Use this advanced option to define the maximum horizontal distance between the associativity points of the reinforcement marks within which identical reinforcement gets merged reinforcement marks. This advanced option only affects merging of reinforcing bar marks pointing to individual reinforcing bars, not marks pointing to a group of reinforcing bars, or marks within a group of reinforcing bars. The default value is 600 mm.

This advanced option is model specific and the setting is saved in the options database.

In the example below, the associativity points of the reinforcement marks are not within the defined distance (600 mm), so the marks will not be merged.

See also

XS_​MAX_​MERGE_​DISTANCE_​IN_​VERTICAL

Merge marks automatically

Was this helpful?
Previous
Next