XS_INTELLIGENCE_MAX_RULE_COUNT
Category in Advanced options dialog: Drawing properties
Use this advanced option only when there are performance issues with associative drawings. Using this advanced option may cause losing of associativity in some cases when objects have been deleted from the model.
Use this advanced option to
decrease the number of associative rules that are
used for one measurement point. A smaller value, for
example 10 (default), is usually enough. A smaller
value may also increase performance and decrease the
database size.
This advanced option also controls the maximum number of shown rules in the dimension associativity rule list.
This advanced option is role specific. When the type SYSTEM(ROLE) is in use, the default value is used. When the type MODEL(ROLE) or DRAWING(ROLE) is in use, you can change the value, which is then the same for all users in the current model.