XS_ENABLE_REBAR_MARK_LEADER_LINE_BASE_POINT_OPTIMIZATION
Category in Advanced options dialog: Concrete detailing
Use this advanced option
to select an optimal place for the associativity point of the reinforcing bar mark
leader line. If set to TRUE, Tekla Structures selects an optimal place for the
associativity point. The associativity point only points to one reinforcing bar
instead of an intersection or overlap of multiple bars.
The optimization is only applied to the marks that have the Placing
method value Free. In practice, this prevents the optimization from moving manually moved marks,
because moving a mark manually changes the value of its Placing
method to Fixed. The default value is TRUE.
This advanced option is model specific and the setting is saved in the options database.