XS_AD_LOAD_COMBINATION_METHOD
Category in Advanced options dialog: Analysis and design
Use this advanced option to define whether a load combination is created instead of a repeated load in STAAD.Pro export from Tekla Structures.
Set to
0 to use
REPEAT LOAD, or set to
1 to use
LOAD COMBINATION.
The default value is
0.
This advanced option is model specific and the setting is saved in the options database.