XS_​BOLT_​DUPLICATE_​TOLERANCE

Category in Advanced options dialog box: Numbering

Note:

Do not use this advanced option in new models. This advanced option was part of a temporary solution that has been replaced with a more comprehensive option.

Instead of the XS_BOLT_DUPLICATE_... advanced options, use the No hole option for Special hole type in the Bolt properties.

If necessary in existing models, when XS_​BOLT_​DUPLICATE_​IGNORE is set to TRUE, use XS_BOLT_DUPLICATE_TOLERANCE to set the location tolerance that defines which bolt holes are considered duplicates and will therefore be ignored in part numbering.

The default value for the tolerance is 3 mm.

Note:

It is not recommended to change this advanced option during a project, but if you do so, you must carry out full numbering.

This advanced option is model specific and the setting is saved in the options database.