XS_BOLT_DUPLICATE_TOLERANCE
Category in Advanced options dialog box: Numbering
Do not use this advanced option in new models. This advanced option was part of a temporary solution that has been replaced with a more comprehensive option.
Instead of the XS_BOLT_DUPLICATE_...
advanced options, use the No hole option for Special hole type in the Bolt properties.
If necessary in existing models, when XS_BOLT_DUPLICATE_IGNORE is set to TRUE
, use
XS_BOLT_DUPLICATE_TOLERANCE
to set the location tolerance that defines
which bolt holes are considered duplicates and will therefore be ignored in part
numbering.
The default value for the tolerance is 3 mm.
It is not recommended to change this advanced option during a project, but if you do so, you must carry out full numbering.
This advanced option is model specific and the setting is saved in the options database.