XS_CHAMFER_DISPLAY_LENGTH_FACTOR
Category
Model view
Use to adjust chamfer length.
Tekla Structures calculates plate chamfer length from the plate side length using the following formula:
XS_CHAMFER_DISPLAY_LENGTH_FACTOR
*
plate side length
. By default this factor is
0.08
.
This advanced option is user specific and the setting is saved in options.bin under the user folder, for example, in C:\Users\<user>\AppData\Local\Trimble\Tekla Structures\<version>\UserSettings. Restart Tekla Structures to activate the new value.