TSAC-4442 |
Concrete components |
Lifting anchor (80): The assignment of the main part has been improved. Previously, the created lifting anchors could in some situations get a non-steel embed as the main part. This has now been fixed. |
TSAC-5089 |
Concrete components |
Rebar coupler: Previously, the component did not identify the primary and secondary rebars based on the given primary side point. This happened when the Rebar coupler component was added to a rebar set. Now this has been fixed. |
TSAC-5206 |
Concrete components |
Pad footing reinforcement (77): Previously, when the third zone had enough space for one rebar only, the rebar was not created. This concerned both the primary and the secondary bars. This has now been fixed. Additionally, you can now define in each zone that rebars are not created. The creation of just one rebar in each zone has been improved so that the rebar is now created in its proper position. |
TSAC-5088 |
Concrete components |
Reinforced concrete stair (95): Anti-material created by the component is now always created in the correct position. |
TSAC-5246 |
Concrete components |
Embedded anchors (8): When a polygon thickening in the insulation layer was created around anchors, the anchors were created at the bottom edge of the thickening and not at the top edge. This has now been fixed. |
TSAC-4879 |
Steel components |
Joining plates (14): Previously, galvanizing holes were not created correctly in the second end plate. This has now been fixed. |
TSAC-5208 |
Steel components |
Cold rolled sleeved (2): Previously, the component did not work correctly for steel sketched Z profiles. This has now been fixed. |
TTSD-40630 |
Import, export, interoperability |
Reference models: Earlier, detailed object level settings did not work for reference models in drawings. This has now been fixed. Particularly, it is now possible to show different reference models with different colors. |
TTSD-42341 |
Import, export, interoperability |
IFC4 export: The property set property value conversion from option UDA value to true or false did not work. This has now been fixed. |
TTSD-42922 |
Import, export, interoperability |
Trimble Connector: Overlay models now work even if you change the model folder location of the Tekla Structures model with the attached overlay models. |
TTSD-29244 |
Import, export, interoperability |
IFC object conversion: The following changes have been made in Copy properties to UDAs: |
TTSD-41552 |
Import, export, interoperability |
IFC2x3 export: Shop welds now belong to the assembly in all export types. |
TTSD-32952 |
Import, export, interoperability |
Reference models: A LandXML reference model sometimes had invalid alignment geometry. This has now been fixed. Note that you need to delete and reinsert the reference model if the data has changed. |
TTSD-42649 |
Import, export, interoperability |
IFC2x3 export: Previously, a broken solid prevented the IFC export. Now broken solids are skipped in the export. We recommend that you diagnose the model periodically, and fix possible model issues. |
TTSD-40172 |
Import, export, interoperability |
IFC4 export: IfcReinforcingMesh has been added to the IFC property set management. |
TTSD-43104 |
Import, export, interoperability |
Reference models: PDF reference model special character handling in file names was broken in the latest service packs. The special character handling has now been improved to the support special characters of the current Windows locale again. |
TTSD-43025 |
Import, export, interoperability |
Reference models: Locked reference models could not be updated during the first refresh attempt even if the advanced option XS_REFRESH_ALSO_LOCKED_REFERENCE_MODELS was set to TRUE . This has now been fixed, and the reference models are updated normally. |
TTSD-41379 |
Import, export, interoperability |
Export drawings to DWG/DXF: The export sometimes placed views to overlapping places when Model space coordinates was set to Local. This has now been fixed. |
TTSD-43115 |
Import, export, interoperability |
Previously, rebars were excluded from pour units when the model containing the pour units was uploaded to Trimble Connect with the Upload model command. This has now been fixed. |
TTSD-5900 |
Import, export, interoperability |
IFC2X3 export: The export does not export steel secondary objects as IfcDiscreteAccessory from now on. It is possible to force previous categorization by setting the new advanced option XS_IFC2X3_EXPORT_SECONDARY_AS_DISCRETEACCESSORY to TRUE . |
TTSD-36249 |
Templates and reports |
The XS_DIMENSION_DECIMAL_SEPARATOR advanced option now works also with reports and templates |
TPLED-196 |
Templates and reports |
Template Editor: Using the CopyField function to a target valuefield that is not output sometimes still created an output. This has now been fixed. |
TTSD-42155 |
Drawings |
If moving a view from a drawing to another drawing does not succeed, the view stays in the original drawing. Earlier, the view was removed from the original drawing. |
TTSD-21184 |
Drawings |
The XS_IGNORE_CUT_VALUE_IN_TEMPLATE advanced option now works correctly when its value is set in an .ini file. |
TTSD-33022 |
Drawings |
Drawing layout (.lay) files whose names are longer than 63 characters are no longer available in the Layout list in drawing properties because Tekla Structures does not allow the use of layout files with names over 63 characters. |
TTSD-34845 |
Drawings |
Moving views between drawings now works more reliably. |
TTSD-43068 |
Drawings |
The deletion of the main part of a drawing is no longer reported as an inconsistency in Diagnose & repair model. |
TSAC-5247 |
Drawings |
Drawing 2D Library: An application error sometimes occurred due to a large amount of details in the Drawing 2D Library. This has now been fixed. |
TTSD-43157 |
Drawings |
The stability of radial grids in drawings has been improved. |
TTSD-42933 |
Drawings |
When working in drawings with different amount of views it could happen that Tekla Structures would crash at some point. This has now been fixed. |
TTSD-42726 |
Drawings |
Tekla Structures application error no longer occurs when you inquire a rebar set in a drawing. |
TTSD-42175 |
Drawings |
A reinforcing mark template in a drawing now works correctly for rebar sets. |
TTSD-42354 |
Drawings |
Reinforcement marks attached to a rebar set are now cloned correctly. |
TTSD-40866 |
Drawings |
Dragging dimension points in a drawing now disables the dimension combining. |
TTSD-38056 |
Drawings |
Previously, grid line labels were sometimes placed incorrectly when modified. This has now been fixed. |
TTSD-42834 |
Drawings |
Rebar pull-out pictures are now drawn more reliably. |
TTSD-40630 |
Drawings |
Earlier, detailed object level settings did not work for reference models in drawings. This has now been fixed. Particularly, it is now possible to show different reference models with different colors |
TTSD-41011 |
Drawings |
Layout editor: The tables in the Tables in use list are now shown in alphabetical order again. |
TTSD-42962 |
System and options |
The XS_CONNECT_UPLOAD_MODEL_FOLDER advanced option has been moved from the Components category to the File locations category. |
TTSD-42663 |
Reinforcement |
Rebar set creation could in some rare cases freeze Tekla Structures. This has now been prevented. |
TTSD-32094 |
Reinforcement |
Rebar sets: Modifiers and splitters now adapt to the new geometry when copying rebar sets by using the Copy special > To another object command.
|
TTSD-40552 |
Reinforcement |
Rebar sets now work better when modifying magnetic grid lines. Earlier, rebar sets did not at all adapt to magnetic grid line changes. |
TTSD-42747 |
Reinforcement |
When creating a rebar mesh using the properties loaded from a settings file, the mesh type was not correctly applied. This has now been fixed. |
TTSD-39497 |
Reinforcement |
The rebar set property modifier grouping option Manual has been extended so that it is now possible to group bars that are not side by side or that are on different sides of an opening. |
TTSD-40508 |
Reinforcement |
Rebar sets: All rebar set modifiers and splitters now adapt when a part is modified. |
TTSD-41718 |
Modeling |
Previously, plates and slabs could rotate or move unwantedly after you had made two or more consecutive edits to the plate, for example, by modifying the chamfer point values, and the plate had been on a different work plane than the global coordinate XY plane. This has now been fixed. |
TTSD-42659 |
Modeling |
Previously, when you numbered parts that had been copied, the copied parts sometimes got a different number than the original part. This has now been fixed. |
TTSD-42864 |
Modeling |
In corrupted multi-user models that contained assemblies with main parts missing, creating reports with the SUPPLEMENT_PART_WEIGHT template attribute caused crashes. This has now been fixed. |
TTSD-43047 |
Modeling |
Tekla Structures now correctly displays rebar sets when using the Assembly > Show Assembly command even if reinforcement is defined as hidden in the display settings. |
TSAC-5172 |
Modeling |
Linear array tool does not duplicate copies anymore if the source object has been selected several times. |
TTSD-39184 |
Modeling |
When using the Create weld to part command to create welds, the weld preparation is now correctly displayed in the model. Previously, you had to refresh the view to correctly display the weld preparation in the model. |
TTSD-43425 |
Tools and components |
Previously, there could be an error when you opened a new model while searching in the Applications & components catalog. This has now been fixed. |
TTSD-40871 |
Tools and components |
Using a mathematical constant, such as PI or e , as a parameter name is not possible anymore in custom components. |
TTSD-41526 |
Tools and components |
Previously, the custom component editor mode could not be closed when saving the component failed because of missing plug-ins. This has now been fixed. |
TTSD-40870 |
Tools and components |
Variable names that contain mathematical operators (+,-,*,/) cannot be used in the custom component editor anymore. |
SOLD-1584 |
User interface |
The Tekla Structures Sign in dialog box is now shown in the selected Tekla Structures language. Previously, it was shown in Simplified Chinese even if Traditional Chinese was selected as the Tekla Structures language. |
TTSD-42900 |
User interface |
Previously, there were issues related to how some special characters were displayed in the property pane. The handling of special characters has now been improved. |
TSAC-5177 |
Import, export, interoperability (concrete) |
BVBS Export: For the Round options Up and Down, there is a new preliminary tolerance for small length differences up to 0.2 mm before performing the rounding. This ensures that values very close to exact increment are not rounded when it is not necessary. |
TSAC-5234 |
Import, export, interoperability (concrete) |
Export Unitechnik (79): Previously, line attributes were not correctly exported in certain cases when there was a cut part former too close to the contour edge. This has now been fixed. |