Releases - review and set for members and walls
Graphically review and set releases in a Review View using the Show/Alter State command Releases attribute.
The Releases attribute is applicable to meshed walls, mid-pier walls and member variants of any material.
The information displayed graphically is controlled by Mode, Entity type, Variant and Fixity Type properties.
| Property | Description |
|---|---|
| Mode |
Toggle - this mode displays the current releases for the selected Entity type and can be used to toggle the releases at a specific location between the available types. Set On - this mode displays the current releases for the selected Entity type and can be used to apply a specific fixity at a specific location. |
| Entity type |
Entity type sets the view information for the selected Entity type you wish to work with, the only types available being Member and Wall. |
| Variant |
Selecting a Variant makes it easier to focus on the specific entity type variant you want to work with. The drop list lists all the variants contained in the current model. |
| Fixity Type |
Fixity Type is only displayed when Mode is Set On. The available types reflect the fixity types available in the Properties dialog for the selected entity type. For example, with the Member entity type selected, they are: Fixed , Moment (pin My), and Moment (pin Mz). |
Set Member releases
Set Wall releases
-
Open a view and switch the view
regime to
Review View.
- On the Review ribbon, select Releases.
- Go to the Properties window.
- In the Attribute list, ensure that Releases is selected.
- Set Entity type to Wall
- If required, select a specific Variant
-
With the Mode set as Toggle, do one of the following:
- Click on a colored zone in a wall panel to toggle the applied
release at that location to switch the release between the valid types,
(the tooltip indicates the current release at the location).
-
If the colored zone is at the top/bottom of a panel the valid types are Fixed, Pinned and Continuous.
-
If the colored zone is at the edge of a meshed panel the valid types are Fixed, Pinned and Disconnected.
-
- Click on a colored zone in a wall panel to toggle the applied
release at that location to switch the release between the valid types,
(the tooltip indicates the current release at the location).
- Alternatively, with the Mode set as Set On, select the Fixity Type required and then click on a colored zone in a wall panel to apply the chosen fixity.