Shear capacity (Columns: EC3 Eurocode)

Tekla Structural Designer
Modified: 3 Oct 2019
2025
Tekla Structural Designer

Shear capacity (Columns: EC3 Eurocode)

The shear check is performed at the point under consideration according to clause 6.2.6(1):

  • for the absolute value of shear force normal to the y-y axis, Vy,Ed, and

  • for the absolute value of shear force normal to the z-z axis, Vz,Ed

The following points should be noted:

  • No account is taken of fastener holes in the flange or web - see 6.2.6 (7)

  • Shear is not combined with torsion and thus the resistance is not reduced as per 6.2.6 (8)

Shear buckling

When the web slenderness exceeds 72ε shear buckling can occur in rolled sections. Tekla Structural Designer designs for shear web buckling with accordance to EN 1993-1-5:2006.

The following should however, be noted:

  • The approach to design assumes a non-rigid end post, this is more conservative than the design that takes the approach assuming a rigid end post.
  • Physical support conditions have been assumed to be equivalent to “transverse stiffeners at supports only”.
  • All hole cut outs must be small in accordance to section EN 1993-1-5:2006 2.3
  • If a grade of steel was to be used other than S335, S355 and S460 η will be taken as 1.00 regardless of National Annex.

As we are only designing for the case where no stiffeners are being used, a → ∞ therefore c → ∞ so Vbf,Rd → 0, where Vbf,Rd is the contribution from the flange - see 5.4(1)

The design assumes negligible contribution to the design shear force VEd from shear from torque, therefore VEd is restricted to 0.5 Vbw,Rd . Tekla Structural Designer will warn you if this limit is exceeded - see 7.1(1)

Was this helpful?