  6. Concrete column and wall design to ACI 318
Apply

Product guides

  • Tekla Structural Designer 2025 Product Guides
  • Tekla Structural Designer 2025 release notes
  • Installation and licensing workflow
  • Get familiar with Tekla Structural Designer
  • Create models
  • Apply loading
  • Analyze models
  • Design models
  • Review models
  • Reports and drawings
  • BIM integration
  • Manage Tekla Structural Designer
  • Engineers handbooks
  • Design code specific information
    • US codes
      • Loading (ASCE 7)
      • Steel design to AISC 360 ASD and LRFD
      • Steel seismic design to AISC 341
      • Concrete design to ACI 318
        • ACI 318-19 updates
        • Limitations (concrete members: ACI 318)
        • Cover to Reinforcement (ACI 318)
        • Concrete beam design to ACI 318
        • Concrete column and wall design to ACI 318
          • Design parameters for longitudinal bars (concrete column: ACI 318)
          • Design parameters for vertical bars (concrete wall: ACI 318)
          • Design parameters for horizontal bars (concrete wall: ACI 318)
          • Ultimate Axial Load Limit (column and wall:ACI 318)
          • Effective length calculations (column and wall:ACI 318)
          • Column stack and wall panel classification (column and wall:ACI 318)
          • Design Moment Calculations (column and wall: ACI 318)
          • Design for combined axial and bending (column and wall:ACI 318)
          • Design parameters for shear (column and wall:ACI 318)
          • Design for in plane shear (concrete wall:ACI 318)
          • Column confinement (column and wall:ACI 318)
          • Seismic design and detailing (columns: ACI 318)
          • Seismic design (concrete wall: ACI 318)
        • Concrete slab design to ACI 318
        • Pad and strip base design to ACI 318
        • Pile cap design to ACI 318
        • Punching shear checks to ACI 318
        • Seismic Design to ACI 318
        • References ACI 318
      • Vibration of floors to DG11
    • Eurocodes
    • British Standards
    • Australian Standards
    • Indian Standards

Concrete column and wall design to ACI 318

Modified: 21 Mar 2025 Tekla Structural Designer 2025

Concrete column and wall design to ACI 318

Find out more about the application of ACI 318 within Tekla Structural Designer with regard to:
  • Design parameters for longitudinal bars (columns)
  • Design parameters for vertical bars (walls)
  • Design parameters for horizontal bars (walls)
  • Ultimate Axial Load Limit
  • Effective length calculations
  • Column stack and wall panel classification
  • Design Moment Calculations
  • Design for combined axial and bending
  • Design parameters for shear
  • Design for in plane shear (walls)
  • Column confinement
  • Seismic design and detailing (columns)
  • Seismic design (walls)
If working to ACI 318-19 note the following important information:
  • Concrete column design (ACI 318-19 update)
  • Beam-column joint shear strength (ACI 318-19 update)
See also
Limitations (concrete members: ACI 318)
Cover to Reinforcement (ACI 318)
Seismic Design to ACI 318
Was this helpful?
Submit
Previous
Next