The classification of the cross section is in accordance with Table 5.2. General columns can be classified as:

  • Plastic Class = 1

  • Compact Class = 2

  • Semi-compact Class = 3

  • Slender Class = 4

Class 4 sections are not allowed.

Implementation of the below clauses is as follows:

  • Classification is determined using 5.5.2 (6) and not 5.5.2 (7).

  • 5.5.2 (9) is not implemented as clause (10) asks for the full classification to be used for buckling resistance.

  • 5.5.2 (11) is not implemented.

  • 5.5.2 (12) is not implemented. A brief study of UK rolled UBs and UCs showed that flange induced buckling in normal rolled sections is not a concern.